The impact of sphygmomanometer placement and cuff placement on blood pressure measurements

被引:0
作者
Zhu, Xiao-Yong [1 ]
Zhang, Pu-Hua [1 ]
Huang, Wen-Yin [1 ]
Huang, Wan [1 ]
Tang, Xin-Hu [1 ]
Yu, Hua [1 ]
Wang, Su-Nan [1 ]
机构
[1] Jiujiang Univ, Affiliated Hosp, Dept Cardiol, Jiujiang, Jiangxi Provinc, Peoples R China
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2024年 / 11卷
基金
中国国家自然科学基金;
关键词
blood pressure; cardiovascular disease; hypertension; electronic sphygmomanometer; mercury sphygmomanometer; ARM;
D O I
10.3389/fcvm.2024.1388313
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Hypertension is the most significant global risk factor for mortality and morbidity, making standardized blood pressure measurement crucial. Objectives: To investigate whether the location of blood pressure monitors and the positioning of cuffs yield differing results in blood pressure measurements. Methods: Patients admitted to the Affiliated Hospital of Jiujiang College between 1 January 2022 and 30 June 2023 were enrolled in this study and randomly allocated into four groups. These groups were defined based on the positioning of monitoring equipment as follows: varied placements of cuffs on automatic blood pressure monitors, different heights for mercury column blood pressure monitors, varied heights for automatic blood pressure monitors, and different orientations for the cuff airbag tubes on electrocardiogram monitors. Blood pressure was measured and recorded for each group, followed by an analysis of the variations in readings across the different setups. Results: In the first cohort of 763 individuals, mean systolic blood pressure measured at the standard upper arm site was 128.8 +/- 10.5 mmHg, compared to 125.3 +/- 10.4 mmHg at the elbow fossa. The corresponding diastolic pressures were 79.2 +/- 10.7 and 75.0 +/- 10.6 mmHg, respectively. The difference in systolic pressure between these positions was significant at 3.48 +/- 3.22 mmHg (t(1)= 29.91, p(1) < 0.001) and for diastolic pressure at 4.23 +/- 1.31mmHg (t(2)= 88.98, p(2) < 0.001). For the subsequent groups, involving 253, 312, and 225 individuals, respectively, blood pressure measurements were analyzed and compared across different methods within each group. All p-values exceeded 0.05, indicating no statistically significant differences. Conclusions: Blood pressure values measured at the elbow fossa position using an upper arm-type automatic sphygmomanometer were found to be lower than those measured at the upper arm position, with a difference of 3.48 mmHg for systolic and 4.23 mmHg for diastolic pressures. It is therefore essential to position the cuff correctly, specifically 2-3 cm above the elbow fossa, when utilizing an upper arm-type automatic sphygmomanometer for blood pressure monitoring. Conversely, the placement of the mercury column sphygmomanometer and the automated sphygmomanometer at varying heights had no significant effect on blood pressure readings. Similarly, the orientation of the electrocardiogram's cuffed balloon tube, whether facing upward or downward, did not influence blood pressure measurement outcomes.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Effect of tissue mechanical properties on cuff-based blood pressure measurements
    Lan, H.
    Al-Jumaily, A. M.
    Lowe, A.
    Hing, W.
    MEDICAL ENGINEERING & PHYSICS, 2011, 33 (10) : 1287 - 1292
  • [22] Blood Pressure Difference Between Cuff Inflation and Deflation by Auscultatory Method: Impact of Hypertension Grade
    Coccina, Francesca
    Pizzicannella, Jacopo
    Trubiani, Oriana
    Pierdomenico, Sante D.
    DIAGNOSTICS, 2025, 15 (06)
  • [23] Impact of cuff positioning on blood pressure measurement accuracy: may a specially designed cuff make a difference?
    Bilo, Grzegorz
    Sala, Oscar
    Perego, Carlotta
    Faini, Andrea
    Gao, Lan
    Gluszewska, Anna
    Ochoa, Juan Eugenio
    Pellegrini, Dario
    Lonati, Laura Maria
    Parati, Gianfranco
    HYPERTENSION RESEARCH, 2017, 40 (06) : 573 - 580
  • [24] Comparison of Radialis Sphygmomanometer in Evaluating the Blood Pressure of Healthy Volunteers
    Rachmat, Hendi Handian
    2016 1ST INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING (IBIOMED): EMPOWERING BIOMEDICAL TECHNOLOGY FOR BETTER FUTURE, 2016, : 43 - 46
  • [25] Comparison of dinamap PRO-100 and mercury sphygmomanometer blood pressure measurements in a population-based study
    Ni, HY
    Wu, C
    Prineas, R
    Shea, S
    Liu, K
    Kronmal, R
    Bild, D
    AMERICAN JOURNAL OF HYPERTENSION, 2006, 19 (04) : 353 - 360
  • [26] Differences in Blood Pressure Measurements Obtained Using an Automatic Oscillometric Sphygmomanometer Depending on Clothes-Wearing Status
    Ki, Ji Hoon
    Oh, Mi Kyeong
    Lee, Soo Hee
    KOREAN JOURNAL OF FAMILY MEDICINE, 2013, 34 (02): : 145 - 155
  • [27] Optimizing cuff width for noninvasive measurement of blood pressure
    Marks, LA
    Groch, A
    BLOOD PRESSURE MONITORING, 2000, 5 (03) : 153 - 158
  • [28] Validating the accuracy of a multifunctional smartwatch sphygmomanometer to monitor blood pressure
    Yi, Li
    Lv, Zhong-Hua
    Hu, Shun-Ying
    Liu, Yu-Qi
    Yan, Jia-Bing
    Zhang, Hui
    Li, Hong-Bao
    Chen, Qin
    Li, Yue-Yang
    Jiang, Yu-Fan
    Zhou, Hao
    Li, Mu-Ding
    Chen, Run-Du
    Li, Xiao-Long
    Zhou, Shan-Shan
    Chen, Yun-Dai
    JOURNAL OF GERIATRIC CARDIOLOGY, 2022, 19 (11) : 843 - 852
  • [29] Identifying Isolated Systolic Hypertension From Upper-Arm Cuff Blood Pressure Compared With Invasive Measurements
    Picone, Dean S.
    Schultz, Martin G.
    Armstrong, Matthew K.
    Black, J. Andrew
    Bos, Willem Jan W.
    Chen, Chen-Huan
    Cheng, Hao-Min
    Cremer, Antoine
    Dwyer, Nathan
    Hughes, Alun D.
    Kim, Hack-Lyoung
    Lacy, Peter S.
    Laugesen, Esben
    Liang, Fuyou
    Ohte, Nobuyuki
    Okada, Sho
    Omboni, Stefano
    Ott, Christian
    Pereira, Telmo
    Pucci, Giacomo
    Schmieder, Roland E.
    Sinha, Manish D.
    Stouffer, George A.
    Takazawa, Kenji
    Roberts-Thomson, Philip
    Wang, Ji-Guang
    Weber, Thomas
    Westerhof, Berend E.
    Williams, Bryan
    Sharman, James E.
    HYPERTENSION, 2021, 77 (02) : 632 - 639
  • [30] Noninvasive Blood Pressure Measurement in Maintenance Hemodialysis Patients: Comparison of Agreement between Oscillometric and Finger-Cuff Methods
    Alfano, Gaetano
    Fontana, Francesco
    Cappelli, Gianni
    NEPHRON, 2017, 136 (04) : 309 - 317