Roles of spectral dual-layer CT, D-dimer concentration, and COVID-19 pneumonia in diagnosis of pulmonary embolism

被引:0
作者
Juza, Tomas [1 ,2 ]
Valek, Vlastimil [1 ]
Vlk, Daniel [2 ]
Dostal, Marek [1 ,2 ]
Andrasina, Tomas [1 ]
机构
[1] Masaryk Univ, Univ Hosp Brno, Fac Med, Dept Radiol & Nucl Med, Jihlavska 340-20, Brno 62500, Czech Republic
[2] Masaryk Univ, Fac Med, Dept Biophys, Kamenice 126-3, CZ-62500 Brno, Czech Republic
关键词
Spectral CT; Dual-energy CT; Pulmonary embolism; COVID-19; D-dimer;
D O I
10.1016/j.ejro.2024.100575
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate advantages of spectral dual-layer computed tomography (CT) in diagnosing pulmonary embolism (PE). To compare D-dimer values in patients with PE and concomitant COVID-19 pneumonia to those in patients without PE and COVID-19 pneumonia. To compare D-dimer values in cases of minor versus extensive PE. Methods: A monocentric retrospective study of 1500 CT pulmonary angiographies (CTPAs). Three groups of 500 consecutive examinations: 1) using conventional multidetector CT (CTC), 2) using spectral dual-layer CT (CTS), and 3) of COVID-19 pneumonia patients using spectral dual-layer CT (COV). Only patients with known D-dimer levels were enrolled in the study. Results: Prevalence of inconclusive PE findings differed significantly between CTS and CTC (0.8 % vs. 5.4 %, p < 0.001). In all groups, D-dimer levels were significantly higher in PE positive patients than in patients without PE (CTC, 8.04 vs. 3.05 mg/L; CTS, 6.92 vs. 2.57 mg/L; COV, 10.26 vs. 2.72 mg/L, p < 0.001). There were also statistically significant differences in D-dimer values between minor and extensive PE in the groups negative for COVID-19 (CTC, 5.16 vs. 8.98 mg/L; CTS 3.52 vs. 9.27 mg/L, p < 0.001). The lowest recorded D-dimer value for proven PE in patients with COVID-19 pneumonia was 1.19 mg/L. Conclusion: CTPAs using spectral dual-layer CT reduce the number of inconclusive PE findings. Plasma D-dimer concentration increases with extent of PE. Cut-off value of D-dimer with 100 % sensitivity for patients with COVID-19 pneumonia could be doubled to 1.0 mg/L. This threshold would have saved 110 (22 %) examinations in our cohort.
引用
收藏
页数:7
相关论文
共 32 条
  • [31] Dual-Energy CT Angiography for Detection of Pulmonary Emboli: Incremental Benefit of Iodine Maps
    Weidman, Elizabeth K.
    Plodkowski, Andrew J.
    Halpenny, Darragh F.
    Hayes, Sara A.
    Perez-Johnston, Rocio
    Zheng, Junting
    Moskowitz, Chava
    Ginsberg, Michelle S.
    [J]. RADIOLOGY, 2018, 289 (02) : 546 - 553
  • [32] Diagnostic Value of D-Dimer in COVID-19: A Meta-Analysis and Meta-Regression
    Zhan, Haoting
    Chen, Haizhen
    Liu, Chenxi
    Cheng, Linlin
    Yan, Songxin
    Li, Haolong
    Li, Yongzhe
    [J]. CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2021, 27