Determination of unbound platinum concentrations in human plasma using ultrafiltration and precipitation methods

被引:0
|
作者
Wen, Xia [1 ,2 ]
Doherty, Cathleen [2 ]
Thompson, Lauren E. [3 ]
Kim, Christine [1 ]
Buckley, Brian S. [2 ]
Jaimes, Edgar A. [4 ]
Joy, Melanie S. [3 ]
Aleksunes, Lauren M. [1 ,2 ,5 ]
机构
[1] Dept Pharmacol & Toxicol, Piscataway, NJ USA
[2] Rutgers State Univ, Environm & Occupat Hlth Sci Inst, Piscataway, NJ USA
[3] Univ Colorado, Colorado Canc Ctr, Skaggs Sch Pharm & Pharmaceut Sci, Sch Med,Div Nephrol,Dept Pharmaceut Sci, Aurora, CO USA
[4] Mem Sloan Kettering Canc Ctr, Dept Med, New York, NY USA
[5] Rutgers Canc Inst New Jersey, New Brunswick, NJ USA
关键词
Cisplatin; Unbound Pt; Ultrafiltration; Nanosep (R) filter; TCA precipitation; CISPLATIN BINDING-SITES; HUMAN SERUM-ALBUMIN; PROTEIN-BINDING; IMPACT; CHROMATOGRAPHY;
D O I
10.1016/j.vascn.2024.107535
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Quantification of the unbound portion of platinum (Pt) in human plasma is important for assessing the pharmacokinetics of the chemotherapeutic drug cisplatin. In this study, we sought to compare the recovery of unbound Pt using Nanosep (R) filters to 1) traditional filters (Centrifree (R), Centrisart (R), Amicon (R)) or trichloroacetic acid (TCA) protein precipitation, and 2) unbound, bound, and total Pt concentrations in clinical specimens. For the tested filters, the impact of 1) molecular weight cut-offs, 2) centrifugation force, and 3) total Pt concentration on Pt binding in human plasma was evaluated. Pt was quantified using inductively coupled-plasma mass spectrometry. In human plasma spiked with 0.9 mu g/mL Pt, the percent of unbound Pt increased at higher centrifugation speeds. By comparison, the percent of unbound Pt was highest (42.1%) following TCA protein precipitation. When total Pt was <= 0.9 mu g/mL, unbound Pt (similar to 20-30%) was consistent across filters. Conversely, when plasma was spiked with Pt exceeding 0.9 mu g/mL, the percent of unbound Pt increased from 36.5 to 48% using ultrafiltration, compared to 63.4% to 79% with TCA precipitation. In patients receiving cisplatin-containing chemotherapy, the fraction of unbound Pt at concentrations exceeding 0.9 mu g/mL ranged between 35 and 90%. Moreover, the unbound fraction of Pt in plasma correlated with the concentration of unbound (R-2 = 0.738) and total Pt (R-2 = 0.335). In summary, this study demonstrates that 1) the percent of unbound Pt is influenced by total and unbound Pt levels in vitro and in clinical specimens, and 2) ultrafiltration with Nanosep (R) filters is a feasible method for quantifying unbound Pt concentrations in human plasma.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A RAPID ULTRAFILTRATION TECHNIQUE FOR THE DETERMINATION OF FREE ANTIEPILEPTIC DRUG CONCENTRATIONS IN PLASMA
    PIPPENGER, CE
    GARLOCK, CM
    DESAULNIERS, CW
    STERNBERG, S
    EPILEPSIA, 1980, 21 (02) : 187 - 187
  • [32] Determination of total and unbound docetaxel in plasma by ultrafiltration and UPLC-MS/MS: application to pharmacokinetic studies
    Ming-Thau Sheu
    Chen-Yuan Wu
    Chia-Yu Su
    Hsiu-O Ho
    Scientific Reports, 7
  • [33] Determination of total and unbound docetaxel in plasma by ultrafiltration and UPLC-MS/MS: application to pharmacokinetic studies
    Sheu, Ming-Thau
    Wu, Chen-Yuan
    Su, Chia-Yu
    Ho, Hsiu-O
    SCIENTIFIC REPORTS, 2017, 7
  • [34] Improved quantitative determination of total and unbound concentrations of six teicoplanin components in human plasma by high performance liquid chromatography
    Hanada, K
    Kobayashi, A
    Okamori, Y
    Kimura, T
    Ogata, H
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2005, 28 (10) : 2023 - 2025
  • [35] Comparison of different methods to determine the unbound fraction of chemicals in human plasma
    Dimitrijevic, D.
    Fabian, E.
    Funk-Weyer, D.
    Landsiedel, R.
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2022, 395 (SUPPL 1) : S67 - S67
  • [36] Determination of sitagliptinin human plasma using protein precipitation and tandem mass spectrometry
    Zeng, Wei
    Xu, Yang
    Constanzer, Marvin
    Woolf, Eric J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (21): : 1817 - 1823
  • [37] Recent advances in the determination of unbound concentration and plasma protein binding of drugs: Analytical methods
    Seyfinejad, Behrouz
    Ozkan, Sibel A.
    Jouyban, Abolghasem
    TALANTA, 2021, 225
  • [38] Determination of unbound platinum after oxaliplatin administration: comparison of currently available methods and influence of various parameters
    Gamelin, E
    Boisdron-Celle, M
    Lebouil, A
    Turcant, A
    Cailleux, A
    Krikorian, A
    Brienza, S
    Cvitkovic, E
    Larra, F
    Robert, J
    Allain, P
    ANTI-CANCER DRUGS, 1998, 9 (03) : 223 - 228
  • [39] Quantitative determination of total and unbound paclitaxel in human plasma following Abraxane treatment
    Gardner, Erin R.
    Dahut, William
    Figg, William D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 213 - 218
  • [40] RAPID ULTRAFILTRATION TECHNIQUE FOR THE DETERMINATION OF FREE DRUG CONCENTRATIONS IN PLASMA .1. TECHNIQUE
    GARLOCK, CM
    PIPPENGER, CE
    DESAULNIERS, CW
    STERNBERG, S
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1117 - 1117