Non-enzymatic glucose sensor using mesoporous carbon screen-printed electrodes modified with cobalt phthalocyanine by phase inversion

被引:7
作者
Gonzalez-Sanchez, Marfa-Isabel [1 ]
Khadhraoui, Hanen [1 ,2 ]
Jimenez-Perez, Rebeca [1 ]
Iniesta, Jesus [3 ,4 ]
Valero, Edelmira [1 ]
机构
[1] Univ Castilla La Mancha UCLM, Higher Tech Sch Ind Engn, Dept Phys Chem, Albacete 02071, Spain
[2] Univ Carthage, Fac Sci Bizerte, LR01 ES15, Lab Phys Mat Struct & Proprietes, Bizerte 7021, Tunisia
[3] Univ Alicante, Phys Chem Dept, Alicante 03690, Spain
[4] Univ Alicante, Inst Electrochem, Alicante 03690, Spain
关键词
Mesoporous carbon; Cobalt phthalocyanine; Phase inversion; Screen-printed electrodes; Glucose sensor; Non-enzymatic sensing; HYDROGEN-PEROXIDE; ELECTROCHEMICAL DETECTION; GRAPHENE; BIOSENSOR; PERFORMANCE; PARAMETERS; NANOTUBES; COMPOSITE; OXIDATION; NANORODS;
D O I
10.1016/j.microc.2024.110314
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of non-enzymatic glucose electrochemical sensors is still required to be used for the determination of glucose in complex biological media. This study presents a straightforward and remarkably efficient tool for the preparation of highly stable and sensitive glucose electrochemical sensors based on the deposition of cobalt phthalocyanine (CoPc) onto mesoporous carbon screen-printed electrodes (MCs). Results show that the MC electrochemical activation (aMC) followed by phase inversion (PI), which consisted of drop casting of CoPc in dimethylformamide onto a wetting electrolyte leading to the electrode aMC-CoPc/PI, enhanced sensitivity towards glucose determination in complex media. The beneficial need for MC surface activation and PI has been explored by scanning electron microscopy, energy dispersive X-ray spectroscopy, Raman spectroscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The aMC-CoPc/PI electrode exhibited the highest electrocatalytic activity of the series (namely, MC-CoPc, MC-CoPc/PI and aMC-CoPc) towards glucose oxidation. By using square wave voltammetry technique, the aMC-CoPc/PI glucose electrochemical sensor demonstrated a sensitivity of 22.3 mu A mM-1 and a low detection limit of 27.4 mu M (S/N = 3) in a linear dynamic range of 0.1 to 3.5 mM. Additionally, it also displayed high selectivity, robust stability, repeatability and reproducibility toward the quantification of glucose concentration in complex samples such as horse serum, intravenous glucose saline solution and culture medium for sperm cells.
引用
收藏
页数:11
相关论文
共 61 条
  • [1] Nanohybrid electrocatalyst based on cobalt phthalocyanine-carbon nanotube-reduced graphene oxide for ultrasensitive detection of glucose in human saliva
    Adeniyi, Omotayo
    Nwahara, Nnamdi
    Mwanza, Daniel
    Nyokong, Tebello
    Mashazi, Philani
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2021, 348
  • [2] Exogenous glucose improves long-standing human sperm motility, viability, and mitochondrial function
    Amaral, Alexandra
    Paiva, Carla
    Baptista, Marta
    Sousa, Ana Paula
    Ramalho-Santos, Joao
    [J]. FERTILITY AND STERILITY, 2011, 96 (04) : 848 - 850
  • [3] Fabrication and characterization of polyethersulfone membranes functionalized with zinc phthalocyanines embedding different substitute groups
    Bilici, Zeynep
    Ozay, Yasin
    Yuzer, Abdulcelil
    Ince, Mine
    Ocakoglu, Kasim
    Dizge, Nadir
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2021, 617
  • [4] Oxygen functional groups improve the energy storage performances of graphene electrochemical supercapacitors
    Cao, Hailiang
    Peng, Xing
    Zhao, Min
    Liu, Peizhi
    Xu, Bingshe
    Guo, Junjie
    [J]. RSC ADVANCES, 2018, 8 (06): : 2858 - 2865
  • [5] Recent progress in the development of porous carbon-based electrodes for sensing applications
    Casanova, Ana
    Iniesta, Jesus
    Gomis-Berenguer, Alicia
    [J]. ANALYST, 2022, 147 (05) : 767 - 783
  • [6] Raman fingerprint of charged impurities in graphene
    Casiraghi, C.
    Pisana, S.
    Novoselov, K. S.
    Geim, A. K.
    Ferrari, A. C.
    [J]. APPLIED PHYSICS LETTERS, 2007, 91 (23)
  • [7] Non-enzymatic electrochemical detection of glucose with a disposable paper-based sensor using a cobalt phthalocyanine ionic liquid graphene composite
    Chaiyo, Sudkate
    Mehmeti, Eda
    Siangproh, Weena
    Thai Long Hoang
    Hai Phong Nguyen
    Chailapakul, Orawon
    Kalcher, Kurt
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 102 : 113 - 120
  • [8] Porous carbon prepared from polyacrylonitrile for lithium-sulfur battery cathodes using phase inversion technique
    Choudhury, Soumyadip
    Fischer, Dieter
    Formanek, Petr
    Simon, Frank
    Stamm, Manfred
    Ionov, Leonid
    [J]. POLYMER, 2018, 151 : 171 - 178
  • [9] Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon ink incorporating glucose oxidase
    Crouch, E
    Cowell, DC
    Hoskins, S
    Pittson, RW
    Hart, JP
    [J]. ANALYTICAL BIOCHEMISTRY, 2005, 347 (01) : 17 - 23
  • [10] Layer-by-layer construction of graphene/cobalt phthalocyanine composite film on activated GCE for application as a nitrite sensor
    Cui, Lili
    Pu, Tao
    Liu, Ying
    He, Xingquan
    [J]. ELECTROCHIMICA ACTA, 2013, 88 : 559 - 564