Measurement and Evaluation of Solar Panel Data Via DC Power Line

被引:0
|
作者
Daldal, Nihat [1 ]
Uzun, Berat [1 ]
Bekiroglu, Erdal [1 ]
机构
[1] Abant Izzet Baysal Univ, Fac Engn, Dept Elect & Elect Engn, Bolu, Turkey
关键词
Powerline Communication; Photovoltaic Solar Panel; FSK Modulation and Demodulation; Frequency-shift keying (FSK);
D O I
10.1109/ICSMARTGRID55722.2022.9848576
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Today, it is important to monitor the data first of all in order to increase the efficiency of solar panels. In this study, parameters affecting the efficiency of photovoltaic panels, such as ambient temperature, panel temperature, humidity, light ratio, panel current, panel voltage were measured at certain time intervals. The data was then transferred to the computer via the PV panel (Power Line Communication, PLC) using the existing photovoltaic panel DC power line with the FSK modulator-demodulator, which was converted into a serial information package and designed, and the data was recorded. Here the panel data is collected entirely via its own energy cable without the use of any lines or wireless units. With Python-based software, graphs of panel parameters were created, the data obtained were analyzed and the factors affecting energy production were examined.
引用
收藏
页码:280 / 284
页数:5
相关论文
共 50 条
  • [1] Circuits for Data Communication through DC Power Line in Solar Farm
    Sirinamaratana, Pairote
    Leelarasmee, Ekachai
    2013 IEEE INTERNATIONAL CONFERENCE OF ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2013,
  • [2] Using a DC to DC converter to power portable electronic equipment from a small solar panel
    Ibrahim, D
    ENERGY AND THE ENVIRONMENT, 1999, : 151 - 155
  • [3] An Emulated PV Source Based on an Unilluminated Solar Panel and DC Power Supply
    Zhou, Zhongfu
    Macaulay, John
    ENERGIES, 2017, 10 (12)
  • [4] DC TO AC INVERTERS FOR SOLAR PANEL
    Rakshaya, N. M.
    Vitoba, P. Ashwanth
    Kalam, Akhtar
    Jamuna, K.
    2023 33RD AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE, AUPEC, 2023,
  • [5] Measurement of Power Line Sagging Using Sensor Data of a Power Line Inspection Robot
    Zengin, Aydin Tarik
    Erdemir, Gokhan
    Akinci, Tahir Cetin
    Seker, Serhat
    IEEE ACCESS, 2020, 8 : 99198 - 99204
  • [6] Operation of DC Drive by Solar Panel Using Maximum Power Point Tracking Technique
    Jain, Alok
    Kumar, Sarvesh
    Bhullar, Suman
    Navin, Nandan Kumar
    APPLICATIONS OF ARTIFICIAL INTELLIGENCE TECHNIQUES IN ENGINEERING, VOL 2, 2019, 697 : 295 - 308
  • [7] MEASUREMENT BIASES IN PANEL DATA
    MEURS, H
    VANWISSEN, L
    VISSER, J
    TRANSPORTATION, 1990, 16 (02) : 175 - 194
  • [8] Evaluation and on-line measurement of tuned power filter performance
    Tong, XQ
    Xu, J
    Xue, JY
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 6771 - 6774
  • [9] Voltage harmonics and DC detection on power transformers via vibration measurement analysis
    Albert, Dennis
    Wuerde, Andre
    Engelen, Christoph
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2024, 141 (7-8): : 528 - 539
  • [10] MPPT algorithm test on a photovoltaic emulating system constructed by a DC power supply and an indoor solar panel
    Zhou, Z.
    Holland, P. M.
    Igic, P.
    ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 460 - 469