Antibody functionalized capacitance sensor for label-free and real-time detection of bacteria and antibiotic susceptibility

被引:3
作者
Zeeshan [1 ]
Bahrami, Sadra [2 ]
Park, Sungsu [2 ]
Cho, Sungbo [1 ,3 ]
机构
[1] Gachon Univ, Dept Elect Engn, 1342 SeongnamDaero, Seongnam Si 13120, Gyeonggi Do, South Korea
[2] Sungkyunkwan Univ SKKU, Sch Mech Engn, 2066 Seobu Ro, Suwon 16419, South Korea
[3] Gachon Univ, Dept Hlth Sci & Technol, GAIHST, Incheon 21999, South Korea
关键词
Antimicrobial susceptibility tests (AST); Antibody immobilization; Minimum inhibitory concentration (MIC); Self-assembled monolayer (SAM); Capacitance sensor array; Disk electrode; COLI; IMMOBILIZATION; IMMUNOSENSOR; RESISTANCE;
D O I
10.1016/j.talanta.2024.125831
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effective management of infectious diseases and the growing concern of antibiotic resistance necessitates accurate and targeted therapies, highlighting the importance of antibiotic susceptibility testing. This study aimed to develop a real-time impedimetric biosensor for identifying and monitoring bacterial growth and antibiotic susceptibility. The biosensor employed a gold 8-channel disk-shaped microelectrode array with specific antibodies as bio-recognition elements. This setup was allowed for the analysis of bacterial samples, including Staphylococcus aureus, Bacillus cereus, and Micrococcus luteus. These microorganisms were successfully cultured and detected within 1 h of incubation even with a minimal bacterial concentration of 10 CFU/ml. Overall, the developed biosensor array exhibits promising capabilities for monitoring S. aureus, B. cereus and M. luteus, showcasing an excellent linear response ranging from 10 to 104 CFU/ml with a detection limit of 0.95, 1.22 and 1.04 CFU/mL respectively. Moreover, real-time monitoring of antibiotic susceptibility was facilitated by changes in capacitance, which dropped when bacteria were exposed to antibiotic doses higher than their minimum inhibitory concentration (MIC), indicating suppressed bacterial growth. The capacitance measurements enabled determination of half-maximal cytotoxic concentrations (CC50) values for each bacteria-antibiotic pair. As a proof-of-concept application, the developed sensor array was employed as a sensing platform for the real time detection of bacteria in milk samples, which ensured the reliability of the sensor for in-field detection of foodborne pathogens and rapid antimicrobial susceptibility tests (ASTs).
引用
收藏
页数:11
相关论文
共 46 条
[1]   Detection of pathogenic Bacteria by Electrochemical Impedance Spectroscopy: Influence of the immobilization strategies on the sensor performance [J].
Barreiros dos Santos, M. ;
Sporer, C. ;
Sanvicens, N. ;
Pascual, N. ;
Errachid, A. ;
Martinez, E. ;
Marco, M. -P. ;
Teixeira, V. ;
Samiter, J. .
PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01) :1291-+
[2]   On the impedance spectroscopy of field-effect biosensors [J].
Bausells, Joan ;
Ben Halima, Hamdi ;
Bellagambi, Francesca G. ;
Alcacer, Albert ;
Pfeiffer, Norman ;
Hangouet, Marie ;
Zine, Nadia ;
Errachid, Abdelhamid .
ELECTROCHEMICAL SCIENCE ADVANCES, 2022, 2 (05)
[3]   Microliter spotting and micro-colony observation: A rapid and simple approach for counting bacterial colony forming units [J].
Bhuyan, Shuvam ;
Yadav, Mohit ;
Giri, Shubhra Jyoti ;
Begum, Shuhada ;
Das, Saurav ;
Phukan, Akash ;
Priyadarshani, Pratiksha ;
Sarkar, Sharmilee ;
Jayswal, Anurag ;
Kabyashree, Kristi ;
Kumar, Aditya ;
Mandal, Manabendra ;
Ray, Suvendra Kumar .
JOURNAL OF MICROBIOLOGICAL METHODS, 2023, 207
[4]   Antibody-functionalised gold nanoparticles-based impedimetric immunosensor: detection methods for better sensitivity [J].
Bohli, Nadra ;
Belkilani, Meryem ;
Mora, Laurence ;
Abdelghani, Adnane .
MICRO & NANO LETTERS, 2019, 14 (06) :629-633
[5]   Electrochemical immunosensors using electrodeposited gold nanostructures for detecting the S proteins from SARS-CoV and SARS-CoV-2 [J].
Brazaca, Lais Canniatti ;
Imamura, Amanda Hikari ;
Gomes, Nathalia Oezau ;
Almeida, Mariana Bortholazzi ;
Scheidt, Desiree Tamara ;
Raymundo-Pereira, Paulo A. ;
Oliveira Jr, Osvaldo N. ;
Janegitz, Bruno Campos ;
Spinola Machado, Sergio Antonio ;
Carrilho, Emanuel .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (18) :5507-5517
[6]   3D impedimetric sensors as a tool for monitoring bacterial response to antibiotics [J].
Brosel-Oliu, S. ;
Mergel, O. ;
Uria, N. ;
Abramova, N. ;
van Rijn, P. ;
Bratov, A. .
LAB ON A CHIP, 2019, 19 (08) :1436-1447
[7]  
Cady P., 1978, Mechanizing Microbiology, P199
[8]   Biogeographical Regionalization of Wine Yeast Communities in Greece and Environmental Drivers of Species Distribution at a Local Scale [J].
Chalvantzi, Ioanna ;
Banilas, Georgios ;
Tassou, Chrysoula ;
Nisiotou, Aspasia .
FRONTIERS IN MICROBIOLOGY, 2021, 12
[9]   A Review on Microfluidics-Based Impedance Biosensors [J].
Chen, Yu-Shih ;
Huang, Chun-Hao ;
Pai, Ping-Ching ;
Seo, Jungmok ;
Lei, Kin Fong .
BIOSENSORS-BASEL, 2023, 13 (01)
[10]   Electrochemical Impedance-Based Biosensors for the Label-Free Detection of the Nucleocapsid Protein from SARS-CoV-2 [J].
Cho, Hana ;
Shim, Suhyun ;
Cho, Won Woo ;
Cho, Sungbo ;
Baek, Hanseung ;
Lee, Sang-Myung ;
Shin, Dong-Sik .
ACS SENSORS, 2022, 7 (06) :1676-1684