Comparison of skin dose of flattening filter and flattening filter-free beam in volumetric modulated arc therapy treatment plan for head and neck cancer

被引:0
作者
Lam Pham Hong [1 ,2 ]
Dung Phan Tien [3 ]
Thai Hoang Huu [4 ]
Lam Nguyen Tung [5 ]
Tu Nguyen Duong [5 ]
Van Anh Nguyen Thi [6 ]
Trang Pham Quang [6 ]
机构
[1] Mil Hosp 103, Ctr Oncol, Hanoi, Vietnam
[2] Vietnam Acad Sci & Technol VAST, Grad Univ Sci & Technol, Hanoi, Vietnam
[3] Vietnam Acad Sci & Technol VAST, Dept Applicat & Dev Technol, Hanoi, Vietnam
[4] E Hosp, Dept Oncol, Hanoi, Vietnam
[5] Hanoi Univ Sci & Technol, Sch Engn Phys, Hanoi, Vietnam
[6] 108 Mil Cent Hosp, Radiat Oncol & Radiosurg Dept, Hanoi, Vietnam
来源
2023 1ST INTERNATIONAL CONFERENCE ON HEALTH SCIENCE AND TECHNOLOGY, ICHST 2023 | 2023年
关键词
FFF; FF; VMAT; skin dose; head and neck cancer; RADIATION-THERAPY; PHASE-II; TOXICITY; DELIVERY; IMRT; RADIOTHERAPY; MANAGEMENT; CARCINOMA;
D O I
10.1109/ICHST59286.2023.10565365
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The study aims to investigate and compare the skin dose in the volumetric modulated arc therapy (VMAT) plan for head and neck cancer using a 6 MV flat-filtered (FF) photon beam and the flattening filter-free (FFF) beam. The computed tomography simulation data of 31 treated head and neck cancer patients was used to re-plan VMAT on Eclipse v13.6 software with the 6 MV FF and 6 MV FFF photon beams of TrueBeam STx Linac. The above plans were quantitatively compared the skin dose including Dmean, Dmax and surface volumes received the same dose level. All the plans have to meet the conditions of irradiating actual patients. In Dmean, the skin dose was significantly lower for the FFF beams than the FF beams in surface thicknesses of 2 mm and 4 mm. The skin dose was significantly higher for the FFF beams than the FF beams with a surface thickness of 1 mm. There was no statistical significance in Dmax and other surface thicknesses of Dmean. The skin surface volumes that received the same dose on the 6 MV FFF VMAT plans are smaller than those on the 6 MV FF plans at different surface thicknesses from 1 mm to 5 mm and various dose levels from 5 Gy to 60 Gy. Comparing the 6 MV FF and FFF VMAT radiotherapy plans for H&N cancer revealed that the skin dose was significantly lower for the FFF beams in surface thicknesses of 2 mm and 4 mm compared to the FF beams. The skin surface volume receiving the same dose (5-60 Gy) was less when the 6 MV FFF photon beam was utilized as opposed to the FF beam.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Radiobiological comparison of flattening filter (FF) and flattening filter-free (FFF) beam in rat laryngeal tissue
    Aras, Serhat
    Tanzer, Ihsan Oguz
    Sayir, Neslihan
    Keles, Mevlut Sait
    Ozgeris, Fatma Betul
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2021, 97 (02) : 249 - 255
  • [22] Reirradiation of nasopharyngeal carcinoma focusing on volumetric modulated arcs with flattening filter-free beams
    Zhuang, M.
    Huang, L.
    Zhu, D.
    Peng, X.
    Lin, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1052)
  • [23] A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer
    Gasic, Daniel
    Ohlhues, Lars
    Brodin, N. Patrik
    Fog, Lotte S.
    Pommer, Tobias
    Bangsgaard, Jens P.
    Rosenschold, Per Munck A. F.
    ACTA ONCOLOGICA, 2014, 53 (08) : 1005 - 1011
  • [24] Dose rate response of Digital Megavolt Imager detector for flattening filter-free beams
    Xu, Zhigang
    Kim, Jinkoo
    Han, James
    Hsia, An Ting
    Ryu, Samuel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 141 - 147
  • [25] Evaluation of Flattening Filter-Free RapidArc and Intensity-Modulated Radiation Therapy Techniques for Postoperative Cervical Cancer Treatment
    Manna, Sumanta
    Singh, Sharad
    Gupta, Pramod Kumar
    Ragul, T.
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2024, 39 (03): : 294 - 306
  • [26] Acceptable fetal dose using flattening filter-free volumetric arc therapy (FFF VMAT) in postoperative chemoradiotherapy of tongue cancer during pregnancy
    Takahashi, Wataru
    Nawa, Kanabu
    Haga, Akihiro
    Yamashita, Hideomi
    Imae, Toshikazu
    Ogita, Mami
    Okuma, Kae
    Abe, Osamu
    Nakagawa, Keiichi
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2020, 20 : 9 - 12
  • [27] Treatment of breast cancer with simultaneous integrated boost in hybrid plan technique Influence of flattening filter-free beams
    Bahrainy, Marzieh
    Kretschmer, Matthias
    Joest, Vincent
    Kasch, Astrid
    Wuerschmidt, Florian
    Dahle, Joerg
    Lorenzen, Joern
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (05) : 333 - 341
  • [28] Surface Dose Investigation of the Flattening Filter-Free Photon Beams
    Wang, Yuenan
    Khan, Mohammad K.
    Ting, Joseph Y.
    Easterling, Stephen B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : E281 - E285
  • [29] Dosimetric Comparison of Commonly Used Volumetric Modulated Arc Therapy Field Arrangements Based on Flattening Filter-Free Beams for Synchronous Bilateral Breast Carcinoma Radiation Therapy
    Zhang, Xingxing
    Shi, Juntian
    Wu, Xiuxiu
    Li, Liting
    Sun, Wei
    Zou, Yongmei
    Chen, Guoquan
    Wu, Shaokun
    Duan, Song
    PRACTICAL RADIATION ONCOLOGY, 2024, 14 (03) : e190 - e202
  • [30] Three-dimensional dose comparison of flattening filter (FF) and flattening filter-free (FFF) radiation therapy by using NIPAM gel dosimetry
    Yao, Chun-Hsu
    Chang, Tung-Hao
    Lin, Chia-Chi
    Lai, Yuan-Chun
    Chen, Chin-Hsing
    Chang, Yuan-Jen
    PLOS ONE, 2019, 14 (02):