Clinical Feasibility of a Markerless Gait Analysis System

被引:1
作者
Kim, Ha Yong [1 ]
An, Young Sun [1 ]
Oh, Seung Hak [1 ]
Lee, Han Cheol [1 ]
机构
[1] Eulji Univ, Coll Med, Dept Orthoped Surg, 95 Dunsanseo-ro, Daejeon 35233, South Korea
关键词
Gait analysis; Pathologic gait; Optical tracking system; Markerless gait analysis; TREADMILL WALKING; KINECT; BIOMECHANICS; INDEX;
D O I
10.4055/cios23065
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The gait analysis method that has been used in clinical practice to date is an optical tracking system (OTS) using a marker, but a markerless gait analysis (MGA) system is being developed because of the expensive cost and complicated examination of the OTS. To apply this MGA clinically, a comparative study of the MGA and OTS methods is necessary. The purpose of this study was to evaluate the compatibility between the OTS and the MGA methods and to evaluate the usefulness of the MGA system in actual clinical settings. Methods: From March 2021 to August 2021, 14 patients underwent gait analysis using the OTS and MGA system, and the spatiotemporal parameters and kinematic results obtained by the 2 methods were compared. To evaluate the practicality of the MGA system in an actual clinical setting, MGA was performed on 14 symptomatic children with idiopathic toe walking, who had been treated with a corrective cast, and the pre-cast and post-cast results were compared. For the OTS, the Motion Analysis Eagle system was used, and for MGA, DH Walk was used. Results: The spatiotemporal parameters showed no significant difference between the OTS and MGA system. The joint angle graphs of the kinematics along the sagittal plane showed similar shapes as a whole, with particularly high correlations in the hip and knee (pelvis: 29.4%, hip joint: 96.7%, knee joint: 94.9%, and ankle joint: 68.5%). A quantified comparison using the CORrelation and Analysis (CORA) score also showed high similarity between the 2 methods. The MGA results of pre-cast application and post-cast removal for children with idiopathic toe walking showed a statistically significant improvement in ankle dorsiflexion after Conclusions: MGA showed a good correlation with the conventional OTS in terms of spatiotemporal parameters and kinematics. We demonstrated that ankle sagittal kinematics improved after treatment by corrective cast in children with idiopathic toe walking using the MGA method. Thus, after the improvement of a few limitations, the MGA system may soon be able to be clinically applied.
引用
收藏
页码:506 / 516
页数:11
相关论文
共 21 条
[1]   Comparison of Markerless and Marker-Based Motion Capture Technologies through Simultaneous Data Collection during Gait: Proof of Concept [J].
Ceseracciu, Elena ;
Sawacha, Zimi ;
Cobelli, Claudio .
PLOS ONE, 2014, 9 (03)
[2]   A Review of the Evolution of Vision-Based Motion Analysis and the Integration of Advanced Computer Vision Methods Towards Developing a Markerless System [J].
Colyer, Steffi L. ;
Evans, Murray ;
Cosker, Darren P. ;
Salo, Aki I. T. .
SPORTS MEDICINE-OPEN, 2018, 4
[3]   Human movement analysis using stereophotogrammetry - Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics [J].
Della Croce, U ;
Leardini, A ;
Chiari, L ;
Cappozzo, A .
GAIT & POSTURE, 2005, 21 (02) :226-237
[4]   Improved kinect-based spatiotemporal and kinematic treadmill gait assessment [J].
Eltoukhy, Moataz ;
Oh, Jeonghoon ;
Kuenze, Christopher ;
Signorile, Joseph .
GAIT & POSTURE, 2017, 51 :77-83
[5]   A comparison of variability in spatiotemporal gait parameters between treadmill and overground walking conditions [J].
Hollman, John H. ;
Watkins, Molly K. ;
Imhoff, Angela C. ;
Braun, Carly E. ;
Akervik, Kristen A. ;
Ness, Debra K. .
GAIT & POSTURE, 2016, 43 :204-209
[6]  
Ibala E., 2019, J Ann Bioeng, V1, P1
[7]   Walking speed influences on gait cycle variability [J].
Jordan, Kimberlee ;
Challis, John H. ;
Newell, Karl M. .
GAIT & POSTURE, 2007, 26 (01) :128-134
[8]  
Ju-Sung Jang,, 2019, [The Korean Society of Sports Science, 한국체육과학회지], V28, P1287, DOI 10.35159/kjss.2019.08.28.4.1287
[9]   Evaluation of Calibrated Kinect Gait Kinematics Using a Vicon Motion Capture System [J].
Lamine, H. ;
Bennour, S. ;
Laribi, M. ;
Romdhane, L. ;
Zaghloul, S. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 :111-112
[10]   Familiarization to treadmill running in young unimpaired adults [J].
Lavcanska, V ;
Taylor, NF ;
Schache, AG .
HUMAN MOVEMENT SCIENCE, 2005, 24 (04) :544-557