Evaluation of pore-fracture microstructure of gypsum rock fragments using micro-CT

被引:4
|
作者
Kosek, Filip [1 ]
Dudak, Jan [2 ]
Tymlova, Veronika [2 ]
Zemlicka, Jan [2 ]
Rimnacova, Daniela [3 ]
Jehlicka, Jan [1 ]
机构
[1] Charles Univ Prague, Inst Geochem Mineral & Mineral Resources, Fac Sci, Albertov 6, Prague 12800, Czech Republic
[2] Czech Tech Univ, Inst Expt & Appl Phys, Husova 240-5, Prague 11000, Czech Republic
[3] Inst Rock Struct & Mech, Czech Acad Sci, 5 Holesovickach 94-41, Prague 8, Czech Republic
关键词
Micro-CT; Gypsum; Weathering; Porosity; Segmentation; Deep learning; U-net; X-RAY MICROTOMOGRAPHY; MERCURY POROSIMETRY; SIZE DISTRIBUTIONS; EVAPORITE BASIN; FACIES; POROSITY;
D O I
10.1016/j.micron.2024.103633
中图分类号
TH742 [显微镜];
学科分类号
摘要
This study utilized X-ray micro-computed tomography (micro-CT) to investigate weathered gypsum rocks which can or do serve as a rock substrate for endolithic organisms, focusing on their internal pore-fracture microstructure, estimating porosity, and quantitative comparison between various samples. Examining sections and reconstructed 3D models provides a more detailed insight into the overall structural conditions within rock fragments and the interconnectivity in pore networks, surpassing the limitations of analyzing individual 2D images. Results revealed diverse gypsum forms, cavities, fractures, and secondary features influenced by weathering. Using deep learning segmentation based on the U-Net models within the Dragonfly software enabled to identify and visualize the porous systems and determinate void space which was used to calculate porosity. This approach allowed to describe what type of microstructures and cavities is responsible for the porous spaces in different gypsum samples. A set of quantitative analysis of the detected void and modeled networks provided a needed information about the development of the pore system, connectivity, and pore size distribution. Comparison with mercury intrusion porosimetry showed that both methods consider different populations of pores. In our case, micro-CT typically detects larger pores (> 10 mu m) which is related to the effective resolution of the scanned images. Still, micro-CT demonstrated to be an efficient tool in examining the internal microstructures of weathered gypsum rocks, with promising implications particularly in geobiology and microbiology for the characterization of lithic habitats.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Evaluation of microvascular anatomy by micro-CT
    Lerman, A
    Ritman, EL
    HERZ, 1999, 24 (07) : 531 - 533
  • [22] Characterization and microfabrication of natural porous rocks: From micro-CT imaging and digital rock modelling to micro-3D-printed rock analogs
    Song, Rui
    Wang, Yao
    Sun, Shuyu
    Liu, Jianjun
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2021, 205
  • [23] ?CT quantitative assessment of the pore-fracture structures and permeability behaviors of long-flame coal treated by infrared rapid heating
    Wu, Mingqiu
    Li, Haitao
    Wang, Liang
    Yang, Xinlei
    Dai, Chongyang
    Yang, Ning
    Li, Jie
    Wang, Yu
    Yu, Minggao
    ENERGY, 2023, 274
  • [24] Study on characterization of micro-fracture of shale based on micro-CT
    Gou Q.
    Xu S.
    Hao F.
    Yang F.
    Wang Y.
    Lu Y.
    Zhang A.
    Cheng X.
    Qing J.
    Gao M.
    Dizhi Xuebao/Acta Geologica Sinica, 2019, 93 (09): : 2372 - 2382
  • [25] Probing the Pore Structure of the Berea Sandstone by Using X-ray Micro-CT in Combination with ImageJ Software
    Hu, Zhazha
    Zhang, Rui
    Zhu, Kai
    Li, Dongyin
    Jin, Yi
    Guo, Wenbing
    Liu, Xiao
    Zhang, Xiaodong
    Zhang, Qian
    MINERALS, 2023, 13 (03)
  • [26] Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage
    Zheng, Y.
    Yang, Y.
    Rogowska, M.
    Gundlach, C.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [27] How image-processing parameters can influence the assessment of dental materials using micro-CT
    Torres, Fernanda Ferrari Esteves
    Jacobs, Reinhilde
    EzEldeen, Mostafa
    de Faria-Vasconcelos, Karla
    Guerreiro-Tanomaru, Juliane Maria
    dos Santos, Bernardo Camargo
    Tanomaru-Filho, Mario
    IMAGING SCIENCE IN DENTISTRY, 2020, 50 (02) : 161 - 168
  • [28] Processing of micro-CT images of granodiorite rock samples using convolutional neural networks (CNN). Part III: Enhancement of Scanco micro-CT images of granodiorite rocks using a 3D convolutional neural network super-resolution algorithm
    Roslin, A.
    Lebedev, M.
    Mitchell, T. R.
    Onederra, I. A.
    Leonardi, C. R.
    MINERALS ENGINEERING, 2023, 195
  • [29] Evaluation of the accuracy of nine electronic apex locators by using Micro-CT
    Connert, T.
    Judenhofer, M. S.
    Huelber-J, M.
    Schell, S.
    Mannheim, J. G.
    Pichler, B. J.
    Loest, C.
    ElAyouti, A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (02) : 223 - 232
  • [30] Permeability estimation on raw micro-CT of carbonate rock samples using deep learning
    dos Anjos, Carlos Eduardo Menezes
    de Matos, Thais Fernandes
    Avila, Manuel Ramon Vargas
    Fernandes, Julio de Castro Vargas
    Surmas, Rodrigo
    Evsukoff, Alexandre Goncaalves
    GEOENERGY SCIENCE AND ENGINEERING, 2023, 222