Experimental and numerical study on the behavior of high strength Q960 steel columns after fire exposure

被引:4
作者
Wang, Weiyong [1 ,2 ]
Li, Yameng [1 ]
Wang, Zhiruoyu [3 ]
Pang, Shiyun [1 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Key Lab New Technol Construction Cities Mt Area, Minist Educ, Chongqing 400045, Peoples R China
[3] Univ Queensland, Adv Engn Bldg, St Lucia, Qld 4072, Australia
关键词
High strength q960 steel; Post to high temperature; Axial compression load capacity; Test and finite element analysis; DESIGN;
D O I
10.1016/j.tws.2024.111748
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-strength steel exhibits extensive potential in large-span buildings and bridges. Therefore, it is of great significance to clarify its mechanical properties particularly in the realm of post -fire building repair and reconstruction, making it imperative to elucidate its bearing capacity after exposure to elevated temperatures. To comprehensively investigate the overall stability of high-strength Q960 steel columns under high-temperature conditions, a series of axial compression bearing capacity tests are conducted on eight Q960 steel columns-four of which featured H-shaped sections and the remaining four being box-shaped sections. The design of these members considered the effects of slenderness ratio and temperature. At the same time, the residual stress and geometric initial defects of the steel column were measured. Furthermore, the axial compression model for Q960 steel columns, encompassing both room and high-temperature scenarios, was established using the ABAQUS finite element software. This model duly accounted for the influence of residual stress and geometric initial defects. Subsequently, the test outcomes, encompassing horizontal and vertical displacements, ultimate bearing capacity, and failure mode, were compared with the results obtained from finite element analysis. This comparison serves to validate the accuracy of the model while facilitating parameter analysis. The results based on both the finite element analysis and experimental findings, indicate that when employing the Chinese code GB 50,017-2017, the stability coefficient calculation for Q960 steel columns following high-temperature exposure yields satisfactory safety margins. In light of these findings, a calculation method is proposed to accurately predict the stability coefficient of Q960 steel columns in the aftermath of high-temperature conditions, thus offering a reliable approach for assessing the stability bearing capacity of such columns in such scenarios. By comparing with EN 1993-1-12 and ANSI/AISC 360-22, it is found that EN 1993-1-12 has a better prediction effect, while ANSI/AISC 360-22 is conservative when the slenderness ratio is small.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Experimental and numerical study on the load-bearing capacity of cold-formed stiffened high-strength steel box columns
    Wang, Ziqi
    Wang, Weiyong
    Gao, Chao
    JOURNAL OF BUILDING ENGINEERING, 2024, 83
  • [32] FIRE RESISTANCE OF STEEL TUBULAR COLUMNS INFILLED WITH ULTRA-HIGH STRENGTH CONCRETE
    Lyu, X.
    Shu, G. P.
    Liew, J. Y. Richard
    Du, Er-F
    ADVANCED STEEL CONSTRUCTION, 2018, 14 (03): : 438 - 460
  • [33] Numerical study of fire resistance of stainless steel circular hollow section columns
    Arrais, Flavio
    Lopes, Nuno
    Real, Paulo Vila
    JOURNAL OF FIRE SCIENCES, 2020, 38 (02) : 156 - 172
  • [34] Experimental study on seismic behavior of high strength steel frames: Local response
    Hu, Fangxin
    Shi, Gang
    ENGINEERING STRUCTURES, 2021, 229
  • [35] Experimental and numerical study on fire resistance of tubed steel-reinforced concrete stub columns under eccentric compression
    Liu, Jiepeng
    Xing, Yonghui
    Song, Keyan
    Wang, Weiyong
    STEEL AND COMPOSITE STRUCTURES, 2021, 41 (04) : 549 - 566
  • [36] Experimental and numerical investigations of fire resistance of continuous high strength steel reinforced concrete T-beams
    Xu, Qingfeng
    Han, Chongqing
    Wang, Yong C.
    Li, Xiangmin
    Chen, Lingzhu
    Liu, Qiao
    FIRE SAFETY JOURNAL, 2015, 78 : 142 - 154
  • [37] Hysteretic behavior of steel fiber-reinforced high-strength concrete columns with high-strength steel bars
    Zhang, Jianwei
    Liu, Juan
    Li, Xiangyu
    Cao, Wanlin
    Chen, Zeqiao
    STRUCTURES, 2021, 33 : 1833 - 1852
  • [38] Investigation the behavior of LWAC encased steel columns after exposure to elevated temperature
    Al-Talqani, Noor Al-Huda
    Al-Thairy, Haitham
    STRUCTURAL CONCRETE, 2024,
  • [39] Creep buckling of high strength Q460 steel columns at elevated temperatures
    Wang, Weiyong
    Zhou, Hongyang
    Xu, Lei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 157 : 414 - 425
  • [40] Performance of concrete-filled stainless steel tubular (CFSST) columns after exposure to fire
    Tan, Qing-Hua
    Gardner, Leroy
    Han, Lin-Hai
    Song, Tian-Yi
    THIN-WALLED STRUCTURES, 2020, 149