High Throughput, Sensitive LC-MS/MS Determination of Bile Acids in Mouse Feces and its Application to Monitoring their Levels of Excretion

被引:0
|
作者
Saracut, Claudiu [1 ]
Copotoiu, Constantin [1 ]
Molnar, Calin [1 ]
Farczadi, Lenard [2 ]
Todoran, Nicoleta [3 ]
Carje, Anca [4 ]
Vlase, Laurian [5 ]
机构
[1] Univ Med & Pharm Tirgu Mures, Fac Med, Dept Surg Sci, Surg 1, 38 Gh Marinescu Str, Targu Mures 540139, Romania
[2] Vim Spectrum SRL, 409 Sighisoarei Str, Targu Mures 547367, Romania
[3] Univ Med & Pharm Tirgu Mures, Fac Pharm, Dept Pharmaceut Technol, 38 Gh Marinescu Str, Targu Mures 540139, Romania
[4] Univ Med & Pharm Tirgu Mures, Fac Pharm, Dept Analyt Chem & Anal Med, 38 Gh Marinescu Str, Targu Mures 540139, Romania
[5] Iuliu Hatieganu Univ Med & Pharm Cluj Napoca, Fac Pharm, Dept Pharmaceut Technol & Biopharmaceut, 13 Emil Isac, Cluj Napoca 400023, Romania
来源
REVISTA DE CHIMIE | 2016年 / 67卷 / 06期
关键词
primary and secondary bile acids; mouse feces; LC-MS/MS; LIQUID-CHROMATOGRAPHY; LITHOCHOLIC ACID; SERUM; MS; VALIDATION;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new rapid high-throughput liquid chromatography with tandem mass spectrometry detection method (LC-MS/MS) was developed for the analysis of chenodeoxycholic acid, cholic acid (primary bile acids) and deoxycholic acid, lithocholic acid, ursodeoxycholic acid (secondary bile acids), from mouse feces. Analytical separation was performed on a Zorbax SB-C18 column with mobile phase consisting of methanol and water in gradient elution, using the detection in single ion monitoring mode, with atmospheric pressure chemical negative ionization. The method was validated with respect to selectivity, linearity (r(2) > 0.99), intra-day precision (CV < 13.81%), accuracy (bias < 5.71%) and can be applied to monitor the simultaneously excretion of bile acids in cases of experimentally studies in which the development of colon cancer diet related models that implicate both primary and secondary bile acids are proposed. This analytical method has the advantage of a total run-time of 6 minutes and the limitation of the following lower limits of quantification: 0.095 mu g/mL cholic acid, 0.116 mu g/mL ursodeoxycholic acid, 0.120 mu g/mL chenodeoxycholic add, 0.230 mu g/mL deoxycholic acid and 0.274 mu g/mL lithocholic acid.
引用
收藏
页码:1154 / 1157
页数:4
相关论文
共 50 条
  • [1] Simultaneous determination of corynoline and acetylcorynoline in human urine by LC-MS/MS and its application to a urinary excretion study
    Liu, Ruijuan
    Zheng, Lu
    Cheng, Minlu
    Wu, Yao
    Gu, Pan
    Liu, Yujie
    Ma, Pengcheng
    Ding, Li
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1014 : 83 - 89
  • [2] A sensitive, high-throughput LC-MS/MS method for measuring catecholamines in low volume serum
    Zheng, Jiamin
    Mandal, Rupasri
    Wishart, David S.
    ANALYTICA CHIMICA ACTA, 2018, 1037 : 159 - 167
  • [3] Determination of piracetam in rat plasma by LC-MS/MS and its application to pharmacokinetics
    Wang, Xianqin
    Zhu, Jiayin
    Xu, Renai
    Yang, Xuezhi
    Wu, Haiya
    Lin, Dan
    Ye, Faqing
    Hu, Lufeng
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (10) : 1108 - 1112
  • [4] Determination of leelamine in mouse plasma by LC-MS/MS and its pharmacokinetics
    Song, Min
    Lee, Doohyun
    Lee, Taeho
    Lee, Sangkyu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 931 : 170 - 173
  • [5] A sensitive LC-MS/MS method for the determination of triptolide and its application to pharmacokinetic research in rats
    Xu, Ye
    Chen, Xiaoyan
    Zhong, Dafang
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (03)
  • [6] Simultaneous determination of Olanzapine and Fluoxetine in human plasma by LC-MS/MS: Its pharmacokinetic application
    Bonde, S. L.
    Bhadane, R. P.
    Gaikwad, Avinash
    Gavali, S. R.
    Katale, D. U.
    Narendiran, A. S.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 90 : 64 - 71
  • [7] Simultaneous characterization of bile acids and their sulfate metabolites in mouse liver, plasma, bile, and urine using LC-MS/MS
    Huang, Jiangeng
    Bathena, Sai Praneeth R.
    Csanaky, Ivan L.
    Alnouti, Yazen
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (05) : 1111 - 1119
  • [8] Determination of cefadroxil in rat plasma and urine using LC-MS/MS and its application to pharmacokinetic and urinary excretion studies
    Jin, Hyo-Eon
    Kim, In-Bong
    Kim, Yu Chul
    Cho, Kwan Hyung
    Maeng, Han-Joo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 103 - 110
  • [9] Determination of androstenone levels in porcine plasma by LC-MS/MS
    Chen, G.
    Ren, L.
    Yang, S. M.
    Qiu, J.
    Kamal-Eldin, A.
    Lundstrom, K.
    FOOD CHEMISTRY, 2010, 122 (04) : 1278 - 1282
  • [10] Targeted LC-MS/MS Profiling of Bile Acids in Various Animal Tissues
    Reiter, Sinah
    Dunkel, Andreas
    Dawid, Corinna
    Hofmann, Thomas
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2021, 69 (36) : 10572 - 10580