An experimental validation of a filtering approach for prompt gamma prediction in a research proton treatment planning system

被引:1
|
作者
Huang, Ze [1 ]
Tian, Liheng [1 ]
Janssens, Guillaume [2 ]
Smeets, Julien [2 ]
Xie, Yunhe [3 ]
Teo, Boon-Keng Kevin [4 ]
Nilsson, Rasmus [5 ]
Traneus, Erik [5 ]
Parodi, Katia [1 ]
Pinto, Marco [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Med Phys, Munich, Germany
[2] Ion Beam Applicat SA, Louvain la Neuve, Belgium
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA USA
[4] Univ Penn, Dept Radiat Oncol, Philadelphia, PA USA
[5] RaySearch Labs AB, Stockholm, Sweden
关键词
prompt gamma range verification; proton therapy; REGGUI; RayStation; filtering approach PG prediction; BEAM RANGE VERIFICATION; MONTE-CARLO; SLIT-CAMERA; PET VERIFICATION; RAY EMISSION; THERAPY; DISTRIBUTIONS; SENSITIVITY; RADIATION; FEASIBILITY;
D O I
10.1088/1361-6560/ad6116
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Prompt gamma (PG) radiation generated from nuclear reactions between protons and tissue nuclei can be employed for range verification in proton therapy. A typical clinical workflow for PG range verification compares the detected PG profile with a predicted one. Recently, a novel analytical PG prediction algorithm based on the so-called filtering formalism has been proposed and implemented in a research version of RayStation (RaySearch Laboratories AB), which is a widely adopted treatment planning system. This work validates the performance of the filtering PG prediction approach. Approach. The said algorithm is validated against experimental data and benchmarked with another well-established PG prediction algorithm implemented in a MATLAB-based software REGGUI. Furthermore, a new workflow based on several PG profile quality criteria and analytical methods is proposed for data selection. The workflow also calculates sensitivity and specificity information, which can help practitioners to decide on irradiation course interruption during treatment and monitor spot selection at the treatment planning stage. With the proposed workflow, the comparison can be performed on a limited number of selected high-quality irradiation spots without neighbouring-spot aggregation. Main results. The mean shifts between the experimental data and the predicted PG detection (PGD) profiles (Delta PGD) by the two algorithms are estimated to be 1.5 +/- 2.1 mm and -0.6 +/- 2.2 mm for the filtering and REGGUI prediction methods, respectively. The Delta PGD difference between two algorithms is observed to be consistent with the beam model difference within uncertainty. However, the filtering approach requires a much shorter computation time compared to the REGGUI approach. Significance. The novel filtering approach is successfully validated against experimental data and another widely used PG prediction algorithm. The workflow designed in this work selects spots with high-quality PGD shift calculation results, and performs sensitivity and specificity analyses to assist clinical decisions.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Simulation Study of a 3-D Multislit Prompt Gamma Imaging System for Proton Therapy Monitoring
    Lu, Wenzhuo
    Zhang, Debin
    Fan, Peng
    Wang, Shi
    Wu, Zhaoxia
    Ma, Tianyu
    Liu, Yaqiang
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (03) : 355 - 365
  • [42] Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system
    Ku, Youngmo
    Choi, Sehoon
    Cho, Jaeho
    Jang, Sehyun
    Jeong, Jong Hwi
    Kim, Sung Hun
    Cho, Sungkoo
    Kim, Chan Hyeong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (09) : 3140 - 3149
  • [43] MRI-based treatment planning for proton radiotherapy: dosimetric validation of a deep learning-based liver synthetic CT generation method
    Liu, Yingzi
    Lei, Yang
    Wang, Yinan
    Wang, Tonghe
    Ren, Lei
    Lin, Liyong
    McDonald, Mark
    Curran, Walter J.
    Liu, Tian
    Zhou, Jun
    Yang, Xiaofeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14)
  • [44] Development of an array-type prompt gamma detection system for the online measurement of the range of the proton beam in a patient: a Monte Carlo feasibility study
    Min, Chul Hee
    Park, Jang Guen
    Kim, Chan Hyeong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (03) : 888 - 891
  • [45] Implementation of the microdosimetric kinetic model using analytical microdosimetry in a treatment planning system for proton therapy
    Bertolet, A.
    Cortes-Giraldo, M. A.
    Carabe-Fernandez, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 69 - 76
  • [46] A triple-imaging-modality system for simultaneous measurements of prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Nakanishi, Kohei
    Yabe, Takuya
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Miyake, Masayasu
    Tanaka, Kazuo S.
    Kataoka, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (05)
  • [47] Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy
    Testa, M.
    Schuemann, J.
    Lu, H. -M.
    Shin, J.
    Faddegon, B.
    Perl, J.
    Paganetti, H.
    MEDICAL PHYSICS, 2013, 40 (12)
  • [48] Implementation and validation of a very-high-energy electron model in the matRad treatment planning system
    Sitarz, Mateusz
    Ronga, Maria Grazia
    Gesualdi, Flavia
    Bonfrate, Anthony
    Wahl, Niklas
    De Marzi, Ludovic
    MEDICAL PHYSICS, 2024, : 518 - 529
  • [49] Validation of automated complex head and neck treatment planning with pencil beam scanning proton therapy
    Hedrick, Samantha Grace
    Petro, Scott
    Ward, Alex
    Morris, Bart
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02):