Thermal behaviour of a transformer mineral oil-tank surface under incipient turn-to-turn short-circuit fault

被引:0
|
作者
Chen, Si [1 ]
Luo, Yingting [2 ]
Sheng, Gehao [1 ]
Jiang, Junfei [2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Elect Engn, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[2] Guangdong Power Grid Co Ltd, Elect Power Res Inst, Guangzhou, Peoples R China
关键词
temperature distribution; temperature measurement; thermal analysis; transformer windings; AGING ASSESSMENT MODEL; FUNDAMENTAL APPROACH;
D O I
10.1049/smt2.12200
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A slight turn-to-turn short-circuit fault in the incipient stage does not trigger fuse protection, and the regular transmission and transformation functions of the transformer within the power grid are not affected very much by the incipient turn-to-turn short-circuit fault. Therefore, the incipient turn-to-turn short-circuit faults are often undetected, resulting in massive accidents. Incipient turn-to-turn short-circuit faults lead to localized overheating in the transformer, which changes the transformer's oil-tank surface temperature (OTST). A thermal simulation model (TSM) is presented. Based on the TSM, OTST data with different load rates and fault parameters are collected. The steady-state and transient characteristics of OTST are analysed by extracting the OTST feature vector and the temperature difference of specific regions. The results show that the growth of the heat production value of faulty coils causes a rise in the OTST; higher faulty coils' locations lead to wider OTST differences; the temperature difference's area S can follow the incipient short-circuit fault in the first 20 min after it occurs, which is faster than the top oil temperature. This study gives insight into the thermal behaviour of OTST, assisting in fault detection and location at the incipient fault stage. This paper proposed a thermal simulation model of the oil-immersed transformer and analysed the oil-tank surface's steady-state and transient thermal behaviours under incipient turn-to-turn short-circuit faults. The oil-tank surface temperature (OTST) feature vector b is proposed to show the overall thermal behaviour of the oil-tank surface, and the temperature difference of the specific regions TF(S, hF) is analysed to show the local thermal behaviour. The proposed dynamic analysis and steady-state methods of analysing the thermal behaviour of OTST can help guide online monitoring and fault detection of transformers. image
引用
收藏
页码:310 / 323
页数:14
相关论文
共 50 条
  • [1] Analysis on Leakage Flux Characteristics of Turn-to-Turn Short-circuit Fault for Power Transformer
    Zheng, Yuping
    Gong, Xinyi
    Pan, Shuyan
    Sun, Jiahao
    Deng, Jinzhao
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (15): : 121 - 127
  • [2] Research on the application of transformer vibration model in the detection of turn-to-turn short-circuit fault
    Wu, Xutao
    Yan, Zhenhua
    Ji, Shengchang
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 1332 - +
  • [3] Electromagnetic-Thermal-Coupled Fault Analysis of PMASynRM With Turn-to-Turn Short-Circuit Involving a Few Strands
    Shi, Yanwen
    Wang, Jiabin
    Wang, Bo
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (01) : 294 - 303
  • [4] Study on Methodology Detecting Turn-to-turn Short Circuit of Transformer
    Quan, Yusheng
    Zhao, Xin
    Chen, Guang
    Zhou, Enze
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 876 - +
  • [5] Comprehensive Modeling and Analysis of Stator Turn-to-Turn Short-Circuit Faults in a DFIG
    Yan, Chenguang
    Wang, Weixiang
    Liu, Qinzhi
    Liu, Zhangheng
    Shu, Jin
    Zhao, Jikai
    Zhang, Baohui
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (08)
  • [6] Simulating the processes in a turn-to-turn short-circuit protection system of induction motors
    Novozhilov, A.N.
    Elektrichestvo, 1998, (01): : 56 - 59
  • [7] Turn-to-Turn Short Circuit Fault Localization in Transformer Winding via Image Processing and Deep Learning Method
    Moradzadeh, Arash
    Moayyed, Hamed
    Mohammadi-Ivatloo, Behnam
    Gharehpetian, G. B.
    Aguiar, A. Pedro
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2022, 18 (07) : 4417 - 4426
  • [8] A Novel Concept of Permanent Magnet Synchronous Generators With Automatic Turn-to-Turn Short-Circuit Fault-Tolerance Capability
    Bai, Yinru
    Wang, Shuhong
    Zhang, Ailing
    Wang, Xuping
    Mao, Jiahui
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (01) : 98 - 108
  • [9] Electromagnetic-thermal coupled fault analysis of PMASynRM with turn-to-turn short circuit involving a few strands
    Shi, Yanwen
    Wang, Jiabin
    Wang, Bo
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 4276 - 4283
  • [10] Fault Isolation and Estimation for Turn-to-Turn Short Circuit in Permanent Magnet Synchronous Motor
    Kang, Yunfeng
    Yao, Lina