Influence of Contrast Media Temperature and Concentration on Patient Comfort and Safety in Computed Tomography

被引:2
作者
Stammen, Lion [1 ,2 ]
Mihl, Casper [1 ,2 ]
Vandewall, Janneke [1 ]
Pennetta, Francesca [1 ]
Hersbach, Ankie [1 ]
Wildberger, Joachim E. [1 ,2 ]
Martens, Bibi [1 ,2 ]
机构
[1] Maastricht Univ Med Ctr, Dept Radiol & Nucl Med, P Debyelaan 25,POB 5800, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, CARIM Sch Cardiovasc Dis, Maastricht, Netherlands
关键词
computed tomography; contrast media; patient comfort; patient safety; attenuation; contrast material warming; viscosity; diagnostic imaging; adverse events; DIFFERENT IODINE CONCENTRATIONS; INJECTION; CT; ANGIOGRAPHY; RADIATION; LIVER;
D O I
10.1097/RLI.0000000000001063
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundPrevious research on the necessity to reduce the viscosity of contrast media (CM) by either prewarming CM before injection during computed tomography (CT) or by using less concentrated CM has yielded conflicting results. In addition, there is limited evidence on patient comfort.ObjectivesThe aim of the study was to examine if prewarming CM, with varying CM concentrations, is superior to CM at room temperature, with respect to patient comfort and safety in CT.Materials and MethodsAll elective patients scheduled for contrast-enhanced CT scans at Maastricht University Medical Center+ between October 27, 2021 and October 31, 2022 were eligible for inclusion when a questionnaire evaluating patient comfort was completed. This 1-year period was divided into 4 intervals (4 groups): group 1 (370 mg I/mL, 37 degrees C), group 2 (370 mg I/mL, room temperature), group 3 (300 mg I/mL, 37 degrees C), and group 4 (300 mg I/mL, room temperature). All CT scans were performed using state of the art equipment (Siemens Healthineers; SOMATOM Force and SOMATOM Definition AS, Forchheim, Germany). Contrast media injections were performed using a dual-head power injector (Stellant; Bayer Healthcare, Berlin, Germany) and individualized to body weight and/or tube voltage, depending on the CM protocols. After the CT scan, patients completed a questionnaire covering the primary outcomes comfort, pain, and adverse events such as feelings of heat, nausea, vomiting, itchiness, urticaria, difficulty breathing, dizziness, goosebumps, or an odd taste. Technicians were asked to report any adverse events, including extravasation and allergic-like reactions. The secondary outcome involved attenuation (in Hounsfield unit, HU), which was evaluated by assessing the HU of the coronary arteries for vascular CT, and liver enhancement in portal venous CT. The Kruskal-Wallis test was used for continuous scale outcomes and chi 2 tests for examining adverse events.ResultsResults showed no significant differences examining comfort score (P = 0.054), pain sensation (P = 0.469), extravasation (P = 0.542), or allergic-like reaction (P = 0.253). Significant differences among the 4 groups were found with respect to heat sensation and dizziness (P = 0.005 and P = 0.047, respectively), showing small effect sizes. All other adverse effects showed no significant results. No significant differences were observed in coronary attenuation among the 4 groups in coronary CT angiography (P = 0.113). When analyzing attenuation in portal venous CT scans, significant differences were found among the 4 groups (P = 0.008).ConclusionsAdministrating prewarmed CM is nonsuperior compared with CM at room temperature in relation to patient comfort and safety, regardless of CM concentration. These findings suggest that prewarming CM before usage is unnecessary, which will improve the efficiency of daily clinical workflow and brings environmentally friendly benefits.
引用
收藏
页码:577 / 582
页数:6
相关论文
共 31 条
[1]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[2]   Effect of Extrinsic Warming of Low-Osmolality CT Contrast Media (Iohexol 350) on Extravasations and Patient Reaction Rates: A Retrospective Study [J].
Basharat, Noor F. ;
Ranganathan, Karthik ;
Kang, Paul T. ;
Gridley, Daniel G. ;
Roh, Albert T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (01) :174-179
[3]   MRI and CT contrast media extravasation: A systematic review [J].
Behzadi, Ashkan Heshmatzadeh ;
Farooq, Zerwa ;
Newhouse, Jeffery H. ;
Prince, Martin R. .
MEDICINE, 2018, 97 (09)
[4]   Technological developments of X-ray computed tomography over half a century: User's influence on protocol optimization [J].
Booij, Ronald ;
Budde, Ricardo P. J. ;
Dijkshoorn, Marcel L. ;
van Straten, Marcel .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
[5]   Contrast agent and radiation dose reduction in abdominal CT by a combination of low tube voltage and advanced image reconstruction algorithms [J].
Buls, Nico ;
Van Gompel, Gert ;
Van Cauteren, Toon ;
Nieboer, Koenraad ;
Willekens, Inneke ;
Verfaillie, Guy ;
Evans, Paul ;
Macholl, Sven ;
Newton, Ben ;
de Mey, Johan .
EUROPEAN RADIOLOGY, 2015, 25 (04) :1023-1031
[6]   Lean Body Weight-Tailored Iodinated Contrast Injection in Obese Patient: Boer versus James Formula [J].
Caruso, Damiano ;
De Santis, Domenico ;
Rivosecchi, Flaminia ;
Zerunian, Marta ;
Panvini, Nicola ;
Montesano, Marta ;
Biondi, Tommaso ;
Bellini, Davide ;
Rengo, Marco ;
Laghi, Andrea .
BIOMED RESEARCH INTERNATIONAL, 2018, 2018
[7]   Rate of Contrast Material Extravasations and Allergic-like Reactions: Effect of Extrinsic Warming of Low-Osmolality Iodinated CT Contrast Material to 37°C [J].
Davenport, Matthew S. ;
Wang, Carolyn L. ;
Bashir, Mustafa R. ;
Neville, Amy M. ;
Paulson, Erik K. .
RADIOLOGY, 2012, 262 (02) :475-484
[8]   A comparison of the use of contrast media with different iodine concentrations for enhanced computed tomography [J].
Du, Yu ;
Wang, Ya-Ning ;
Wang, Qi ;
Qi, Xiao-Hui ;
Shi, Gao-Feng ;
Jia, Li-Tao ;
Wang, Xiang-Ming ;
Shi, Jia-Bao ;
Liu, Feng-Yun ;
Wang, Li-Jia ;
Liu, Xiang .
FRONTIERS IN PHYSIOLOGY, 2023, 14
[9]   Impact of Contrast Media Concentration on Low-Kilovolt Computed Tomography Angiography A Systematic Preclinical Approach [J].
Fleischmann, Ulrike ;
Pietsch, Hubertus ;
Korporaal, Johannes G. ;
Flohr, Thomas G. ;
Uder, Michael ;
Jost, Gregor ;
Lell, Michael M. .
INVESTIGATIVE RADIOLOGY, 2018, 53 (05) :264-270
[10]   Computed tomography in clinical practice [J].
Garvey, CJ ;
Hanlon, R .
BMJ-BRITISH MEDICAL JOURNAL, 2002, 324 (7345) :1077-1080