Enhancing the performance of the hybrid battery thermal management system with different fin structures at extreme discharge conditions

被引:1
|
作者
Kavasogullari, Baris [1 ]
Karagoz, Mucahit Emin [2 ]
Onel, Mehmet Nurullah [1 ]
Yildiz, Ali Suat [3 ]
Bicer, Emre [4 ]
机构
[1] Sivas Univ Sci & Technol, Astronaut Engn Dept, TR-58000 Sivas, Turkiye
[2] Sivas Univ Sci & Technol, Aeronaut Engn Dept, Sivas, Turkiye
[3] Sivas Univ Sci & Technol, Mech Engn Dept, Sivas, Turkiye
[4] Sivas Univ Sci & Technol, Engn Fundamental Sci Dept, Sivas, Turkiye
关键词
Battery thermal management; extreme discharge; fin; heat transfer; hybrid; numerical; PHASE-CHANGE MATERIALS; OPTIMIZATION; MODULE;
D O I
10.1080/10407782.2024.2363506
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study aims to enhance the performance of the air-cooled hybrid battery thermal management system (BTMS) by using fins under extreme discharge conditions such as 7C, 9C, and 11C. In this context, five different fin structures, Type-I (no fin), Type-II (rectangular), Type-III (extended), Type-IV (blade), and Type-V (triangular), were modeled, and numerical analyses of the developed BTMSs were performed using COMSOL Multiphysics software. In the numerical analysis, three different phase change materials (PCM-1, PCM-2, and PCM-3) with three different thicknesses (tPCM) of 4, 6, and 8 mm were considered, and the airflow was supplied to the system at three different Reynolds (Re) numbers of 100, 200, and 400. In this way, the effects of the BTMS types, tPCM, PCM types, and air velocity on the battery pack temperature distribution (Delta T), PCM melting uniformity (Delta F), and maximum battery cell temperature (Tmax) in the hybrid BTMS were investigated. As a result of the analyses, the maximum Delta T was found to be 5.58 degrees C for the case involving Type-II and PCM-1 with tPCM of 4 mm at 11C. PCM-2 exhibited the best performance for all BTMS types with a tPCM of 4 mm at 9C. However, at 11C, only the case involving PCM-3 with a tPCM of 6 mm and Type-V could maintain the Tmax under 60 degrees C. Moreover, the results obtained from the numerical analysis revealed that the use of fins significantly increased the PCM melting uniformity.
引用
收藏
页数:23
相关论文
共 50 条
  • [21] Optimal distribution of the fin structures in a phase change material module for battery thermal management
    Chen, Zhifeng
    Wang, Shuo
    Dang, Chao
    Yin, Liaofei
    Ren, Honglei
    JOURNAL OF ENERGY STORAGE, 2024, 99
  • [22] Enhancing the performance of liquid-based battery thermal management system by porous substrate minichannel
    Sarvar-Ardeh, Sajjad
    Rafee, Roohollah
    Rashidi, Saman
    JOURNAL OF ENERGY STORAGE, 2023, 71
  • [23] Enhancing Thermal Performance and Cooling Solutions of Phase Change Material in Battery Thermal Management System: A Computational Analysis
    Singh, Gourav Kumar
    Patel, Jay R.
    Rathod, Manish K.
    ENERGY STORAGE, 2024, 6 (06)
  • [24] Thermal management performance of a fin-enhanced phase change material system for the lithium-ion battery
    Zheng Nianben
    Fan Ruijin
    Sun Zhiqiang
    Zhou Tian
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (09) : 7617 - 7629
  • [25] A triple-hybrid battery thermal management system with drop-shaped fin channels for improving weather tolerance
    An, Zhiguo
    Liu, Huaixi
    Gao, Weilin
    Zhang, Jianping
    ENERGY, 2024, 307
  • [26] Performance analysis of liquid cooling battery thermal management system in different cooling cases
    Li, Ming
    Ma, Shiming
    Jin, Hui
    Wang, Rujin
    Jiang, Yan
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [27] Impact of system structure on the performance of a hybrid thermal management system for a Li-ion battery module
    Bamdezh, M. A.
    Molaeimanesh, G. R.
    JOURNAL OF POWER SOURCES, 2020, 457
  • [28] Heat discharge performance of metal hydride thermal battery under different heat transfer conditions: Experimental findings
    Nyamsi, Serge Nyallang
    Davids, Wafeeq
    Tolj, Ivan
    Pasupathi, Sivakumar
    Lototskyy, Mykhaylo
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [29] Performance analysis of a battery thermal management system combining thermoelectric, composite phase change material, and liquid cooling under extreme operating conditions
    Luo, Ding
    Wu, Zihao
    Yan, Yuying
    Sun, Zeyu
    Yang, Lin
    Cao, Bingyang
    JOURNAL OF ENERGY STORAGE, 2024, 95
  • [30] Effective temperature control of a thermoelectric-based battery thermal management system under extreme temperature conditions
    Luo, Ding
    Zhao, Ye
    Cao, Jin
    Wu, Zihao
    Yang, Xuelin
    Chen, Hao
    JOURNAL OF ENERGY STORAGE, 2024, 103