Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy

被引:1
|
作者
Consorti, Giuseppe [1 ]
Betti, Enrico [1 ]
Catarzi, Lisa [1 ,2 ]
机构
[1] Azienda Osped Univ Ospedali Riuniti Ancona, Dept Maxillofacial Surg, Umberto, Italy
[2] Univ Siena, Dept Maxillofacial Surg, Siena, Italy
关键词
Computer -assisted surgery; Orbital fracture; Blow-out fracture; Customized orbital implant; Preformed titanium mesh; Intraoperative navigation; FLOOR;
D O I
10.1016/j.jcms.2024.02.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to compare the accuracy of inferomedial orbital fracture restoration using customized orbital implant versus 3D preformed titanium mesh. Patients were divided into two groups. Group 1 underwent surgery with customized orbital implants and intraoperative navigation, while group 2 was treated using 3D preformed titanium meshes with preoperative virtual surgical planning (VSP) and intraoperative navigation. Reconstruction accuracy was assessed by: (1) comparing the postoperative reconstruction mesh position with the preoperative VSP; and (2) measuring the difference between the reconstructed and unaffected orbital volume. Pre- and postoperative diplopia and enophthalmos were also evaluated. Fifty-two patients were enrolled (25 in group 1 vs 27 in group 2). The mean difference between final plate position and ideal digital plan was 0.62 mm (SD = 0.235) in group 1 and 0.69 mm (SD = 0.246) in group 2, with no statistical difference between the groups ( p = 0.282). The mean volume differences between the reconstructed and unaffected orbits were 0.95 ml and 1.02 ml in group 1 and group 2, respectively, with no significant difference between the groups ( p = 0.860). Overall clinical improvements, as well as complications, were similar. 3D preformed titanium meshes can reconstruct inferomedial fractures with the same accuracy as customized implants. Therefore, in clinical practice, it is recommended to use 3D preformed meshes for this type of fracture due to their excellent results and the potential for reducing time and costs.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 26 条
  • [1] Accuracy of intraoperative navigation for orbital fracture repair: A retrospective morphometric analysis
    Raveggi, Elisa
    Gerbino, Giovanni
    Autorino, Umberto
    Novaresio, Andrea
    Ramieri, Guglielmo
    Zavattero, Emanuele
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2023, 51 (02) : 107 - 116
  • [2] Post-traumatic orbital reconstruction comparing preformed versus non preformed titanium mesh plates
    Momjian, A.
    Heuberger, J.
    Scolozzi, P.
    REVUE DE STOMATOLOGIE ET DE CHIRURGIE MAXILLO-FACIALE, 2011, 112 (03): : 145 - 150
  • [3] Presurgical Virtual Planning and Intraoperative Navigation with 3D-Preformed Mesh: A New Protocol for Primary Orbital Fracture Reconstruction
    Consorti, Giuseppe
    Monarchi, Gabriele
    Catarzi, Lisa
    LIFE-BASEL, 2024, 14 (04):
  • [4] Titanium Mesh versus Medpor Implant in Orbital Floor Reconstructions: A Comparative Study
    Marella, Vishnu Gowtham
    Rohit
    Khetrapal, Prateek
    Gangasani, Alankrutha
    Bhanot, Rishabh
    Uppal, Ashish
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 76 - 79
  • [5] Individually preformed titanium mesh implants for a true-to-original repair of orbital fractures
    Schoen, R.
    Metzger, M. C.
    Zizelmann, C.
    Weyer, N.
    Schmelzeisen, R.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (11) : 990 - 995
  • [6] Orbital fracture repair outcomes with preformed titanium mesh implants and comparison to porous polyethylene coated titanium sheets
    Peng, Michelle Y.
    Merbs, Shannath L.
    Grant, Michael P.
    Mahoney, Nicholas R.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (02) : 271 - 274
  • [7] A Novel Patient-specific Titanium Mesh Implant Design for Reconstruction of Complex Orbital Fracture
    Kittichokechai, Pakaporn
    Sirichatchai, Kanin
    Puncreobutr, Chedtha
    Lohwongwatana, Boonrat
    Saonanon, Preamjit
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2022, 10 (01) : E4081
  • [8] Accuracy of globe-sparing orbital reconstruction using individually bent titanium mesh: A comparative study
    Soh, Hui Yuh
    Sun, Qian
    Hu, Lei-Hao
    Wang, Yang
    Mao, Chi
    Peng, Xin
    Zhang, Wen-Bo
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (06) : 1971 - 1978
  • [9] Case Report: Facial fracture sequelae: the importance of using a specific customized implant (PSI) for orbital reconstruction
    Pulino, Bianca
    Fonseca, Leonardo Alckmin Hotz
    Vieira, Eduardo Hochuli
    Piteri Filho, Jose Roberto
    de Macedo, Thiago Felippe Oliveira
    D'Amado, Marcelo Pigatto
    Pereira, Rodrigo
    Santos, Igor Alexandre Damasceno
    Ilesan, Robert
    Moreira, Henrique Cabrini
    Viana, Drielli
    Guerra, Raphael Capelli
    FRONTIERS IN SURGERY, 2024, 11
  • [10] Accuracy and Predictability in Use of AO Three-Dimensionally Preformed Titanium Mesh Plates for Posttraumatic Orbital Reconstruction: A Pilot Study
    Scolozzi, Paolo
    Momjian, Armen
    Heuberger, Joris
    Andersen, Elene
    Broome, Martin
    Terzic, Andrej
    Jaques, Bertrand
    JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (04) : 1108 - 1113