MULTI-PARAMETERS SENSITIVITY ANALYSIS OF OVERALL COOLING EFFECTIVENESS ON TURBINE BLADE AND NUMERICAL INVESTIGATION OF INTERNAL COOLING STRUCTURES ON HEAT TRANSFER

被引:0
作者
Liu, Runzhou [1 ]
Li, Haiwang [1 ]
You, Ruquan [1 ]
Tao, Zhi [2 ]
机构
[1] Beihang Univ, Res Inst Aeroengine, Beijing 100191, Peoples R China
[2] Beihang Univ, Sch Energy & Power Engn, Beijing 100191, Peoples R China
来源
PROCEEDINGS OF ASME TURBO EXPO 2022: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2022, VOL 6A | 2022年
基金
中国国家自然科学基金;
关键词
overall cooling effectiveness; conjugate heat transfer; numerical simulation; sensitivity analysis;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Turbine blade overall cooling effectiveness is a conjugate result under the influence of various parameters. In order to analyze the overall cooling effectiveness more accurately, we have to categorize all the influencing parameters. This paper builds a one-dimensional conjugate heat transfer model with four parameters which are adiabatic film cooling effectiveness, heat transfer coefficient ratio between blade external surface (h(g)) and internal surface(h(i)), internal coolant warming factor (T-g-T-w,T-t/T-g-T-c), Biot number. The effects of different internal cooling structures, film hole inclined angle and blowing ratio on flow and heat transfer characteristic were numerically investigated based on flat-plate film hole model and impingement-effusion model, where 3-D steady RANS method with SST k-omega model was used. V-rib, 45 degrees inclined rib, 90 degrees rib and dimple were adopted to compare with smooth internal channel. The results show that four dimensionless parameters (adiabatic film cooling effectiveness, heat transfer coefficient ratio, warming factor, Biot number) are positively correlated with overall cooling effectiveness. The overall cooling effectiveness is the most sensitive to adiabatic film cooling effectiveness, followed by warming factor. This indicates that the adiabatic film cooling effectiveness is the worthiest to improve. The numerical results show that the ribs and dimple structures have little influence on the distribution of adiabatic film cooling effectiveness and Biot number on the mainstream side. The 45 degrees rib presents higher overall cooling effectiveness.
引用
收藏
页数:10
相关论文
共 22 条
[1]  
Albert J. E., P ASME TURB EXP 2004, P251
[2]  
Albert J. E., P ASME 2011 TURB EXP, P629
[3]  
Bohn D., P ASME TURB EXP 2003, P247
[4]  
Chavez K., P ASME TURB EXP 2016
[5]   Heat transfer augmentation using a rib-dimple compound cooling technique [J].
Choi, Eun Yeong ;
Choi, Yong Duck ;
Lee, Won Suk ;
Chung, Jin Teak ;
Kwak, Jae Su .
APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) :435-441
[6]  
Dees J. E., P ASME TURB EXP 2010, P447
[7]  
Ding Y. -f., P ASME TURB EXP 2019
[8]   Sensitivity analysis of internal layout and coating thickness to overall cooling performances of laminated cooling configurations with surface thermal barrier coatings [J].
Huang, Xin ;
Pu, Jian ;
Wang, Jian-hua ;
Qu, Yun-feng ;
He, Jia-hui .
APPLIED THERMAL ENGINEERING, 2020, 181
[9]   Study on analogy principle of overall cooling effectiveness for composite cooling structures with impingement and effusion [J].
Liu, Cun-liang ;
Xie, Gang ;
Wang, Rui ;
Ye, Lin .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 :639-650
[10]  
Na S, 2007, PROCEEDINGS OF THE ASME TURBO EXPO 2007, VOL 4, PTS A AND B, P545