NOISE REDUCTION ANALYSIS OF ELECTRONIC DEVICE COOLING FAN WITH DUCT AND ITS APPLICATION UNDER VARIABLE WORKING CONDITIONS

被引:0
|
作者
Sun, Zonghan [1 ]
Tian, Jie [1 ]
Liskiewicz, Grzegorz [2 ]
Du, Zhaohui [1 ]
Ouyang, Hua [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai, Peoples R China
[2] Lodz Univ Technol, Inst Turbomachinery, Lodz, Poland
来源
PROCEEDINGS OF ASME TURBO EXPO 2021: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 2C | 2021年
关键词
Cooling fan; noise reduction; variable working condition; CFD; POD; LOW-SPEED FAN; ACTIVE CONTROL; TURBULENCE; ROTOR; GENERATION; SOUND;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A noise reduction method for axial flow fans using a short inlet duct is proposed. The pattern of noise reduction imposed by the short inlet duct on the axial flow cooling fan under variable working conditions was experimentally and numerically examined. A 2-cm inlet duct was found to reduce tonal noise. As the tip Mach number of the fan increased from 0.049 to 0.156, the reduction in the total average sound pressure level at 1 m from the fan increased from 0.8 dB(A) to 4.3 dB(A), and further achieved 4.8 dB(A) when a 1-cm inlet duct was used. The steady computational fluid dynamics (CFD) showed that the inlet duct has little effect on the aerodynamic performance of the fan. The results of the full passage unsteady calculation at the maximum flow rate showed that the duct has a significant influence on the suction vortexes caused by the inlet flow non-uniformity. The suction vortexes move upstream to weaken the interaction with the rotor blades, which significantly reduces the pulsating pressure on the blades. The sound pressure level (SPL) at the blade passing frequency (BPF) contributed by the thrust force was calculated to reduce by 36 dB at a 135 degrees observer angle, reflecting the rectification effect of the duct on the non-uniform inlet flow and the improvement in characteristics of the noise source. The proper orthogonal decomposition (POD) of the static pressure field on the blades verified that the main spatial mode is more uniformly distributed due to the duct, and energy owing to the rotor-inlet interaction decreases. A speed regulation strategy for the cooling fan with short inlet duct is proposed, which provides guidance for the application of this noise reduction method.
引用
收藏
页数:10
相关论文
共 10 条
  • [1] Noise Reduction Analysis of Electronic Device Cooling Fan With Duct and Its Application Under Variable Working Conditions
    Sun, Zonghan
    Tian, Jie
    Litkiewicz, Grzegorz
    Du, Zhaohui
    Ouyang, Hua
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2022, 144 (02):
  • [2] Cooling fan aerodynamic noise reduction with short inlet duct and its applicability
    Sun, Zonghan
    Tian, Jie
    Zhang, Tong
    Du, Zhaohui
    Ouyang, Hua
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 148 : 117 - 130
  • [3] Design of sinusoidal-shaped inlet duct for acoustic mode modulation noise reduction of cooling fan
    Sun, Zonghan
    Tian, Jie
    Zheng, Yuhang
    Zhu, Xiaocheng
    Du, Zhaohui
    Ouyang, Hua
    APPLIED ACOUSTICS, 2024, 216
  • [4] Design and application of a perforated panel system to a household refrigerator for cooling fan noise reduction
    Seo, J-Y
    Kim, W-J
    Won, J-S
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2012, 226 (C3) : 785 - 797
  • [5] Vibration characteristics analysis of spur gear pair with crack fault under variable working conditions
    Dai P.
    Wang J.
    Lu J.
    Yan S.
    Qian Z.
    Wang F.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2022, 41 (11): : 225 - 234
  • [6] Analysis of Dynamic Characteristics and Adaptive Robust Control of Electromagnetic Actuators Under Variable Working Conditions
    Zhao, Degeng
    Zhang, Jinjie
    Dong, Liangyu
    Peng, Yang
    Wang, Yao
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (11) : 14855 - 14873
  • [7] Health status monitoring of high-speed train brake pads considering noise under variable working conditions
    Kang, Zhuang
    Zhang, Min
    Cheng, Wenming
    Hu, Ruohui
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2024, 23 (03): : 1449 - 1467
  • [8] Tri-axial vibration information fusion model and its application to gear fault diagnosis in variable working conditions
    Yang, Jianwei
    Bai, Yongliang
    Wang, Jinhai
    Zhao, Yue
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (09)
  • [9] Analysis on the performance of low-load feed water heating system with jet heat pump under variable working conditions
    Li B.
    Zhang G.
    Chen W.
    Liu J.
    Liu, Jiping, 1600, Xi'an Jiaotong University (51): : 65 - 71
  • [10] The optimized local sparse parallel multi-channel deep convolutional neural network-LSTM and the application in bearing fault diagnosis under noise and variable working condition
    Zhang, XiaoLi
    Wang, Fangzhen
    Zhou, Yongqing
    Liang, Wang
    Luo, Xin
    Fan, Panfeng
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2025, 239 (01) : 205 - 218