High-intensity focused ultrasound ablation combined with immunotherapy for treating liver metastases: A prospective non-randomized trial

被引:1
|
作者
Yang, Xiyue [1 ,2 ,3 ]
Liao, Yao [2 ,3 ]
Fan, Lingli [1 ,2 ,3 ]
Lin, Binwei [1 ,2 ,3 ]
Li, Jie [1 ,3 ]
Wu, Danfeng [1 ,3 ]
Liao, Dongbiao [1 ,3 ]
Yuan, Li [1 ,3 ]
Liu, Jihui [1 ,3 ]
Gao, Feng [1 ,2 ,3 ,4 ]
Feng, Gang [1 ,3 ]
Du, Xiaobo [1 ,2 ,3 ,4 ]
机构
[1] Mianyang Cent Hosp, Dept Oncol, Mianyang, Peoples R China
[2] Chongqing Med Univ, Coll Biomed Engn, State Key Lab Ultrasound Med & Engn, Chongqing, Peoples R China
[3] Tianjins Clin Res Ctr Canc, Tianjin, Peoples R China
[4] Chongqing Med Univ, Chongqing Key Lab Biomed Engn, Chongqing, Peoples R China
来源
PLOS ONE | 2024年 / 19卷 / 07期
关键词
UROTHELIAL CARCINOMA; THERAPY; COMBINATION; TUMORS; IRRADIATION; GENERATION;
D O I
10.1371/journal.pone.0306595
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose Given the unique features of the liver, it is necessary to combine immunotherapy with other therapies to improve its efficacy in patients of advanced cancer with liver metastases (LM). High-intensity focused ultrasound (HIFU) ablation is now widely used in clinical practice and can enhanced immune benefits. The study is intended to prospectively evaluate the safety and clinical feasibility of HIFU ablation in combination with systemic immunotherapy for patients with liver metastases.Methods The study enrolled 14 patients with LM who received ultrasound-guided HIFU ablation combined with immune checkpoint inhibitors (ICIs) such as anti-programmed cell death protein 1 (anti-PD-1 agents manufactured in China) at Mianyang Central Hospital. Patients were followed up for adverse events (AEs) during the trial, using the CommonTerminology Criteria for Adverse Events v5.0(CTCAE v5.0) as the standard. Tumour response after treatment was assessed using computerized tomography.Results The 14 patients (age range, 35-84 years) underwent HIFU ablation at 19 metastatic sites and systemic immunotherapy. The mean lesion volume was 179.9 cm3 (maximum: 733.1 cm3). Median follow-up for this trial was 9 months (range: 3-21) months. The study is clinically feasible and acceptable to patients.Conclusion This prospective study confirmed that HIFU combined with immunotherapy is clinically feasible and safe for treating liver metastases.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
    Dupre, Aurelien
    Melodelima, David
    Perol, David
    Chen, Yao
    Vincenot, Jeremy
    Chapelon, Jean-Yves
    Rivoire, Michel
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (143):
  • [2] High-Intensity Focused Ultrasound Ablation for the Treatment of Colorectal Liver Metastases During an Open Procedure Study on the Pig
    Parmentier, Hubert
    Melodelima, David
    N'Djin, Apoutou
    Chesnais, Sabrina
    Chapelon, Jean Yves
    Rivoire, Michel
    ANNALS OF SURGERY, 2009, 249 (01) : 129 - 136
  • [3] Focal High-Intensity Focused Ultrasound Ablation of the Prostate
    Abrams, Lauren R.
    Koch, Michael O.
    Bahler, Clinton D.
    JOURNAL OF ENDOUROLOGY, 2021, 35 : S24 - S32
  • [4] High-intensity focused ultrasound ablation around the tubing
    Siu, Jun Yang
    Liu, Chenhui
    Zhou, Yufeng
    PLOS ONE, 2017, 12 (11):
  • [5] Septal Ablation Induced by Transthoracic High-Intensity Focused Ultrasound in Canines
    Rong, Shunkang
    Woo, Kamsang
    Zhou, Qi
    Zhu, Que
    Wu, Qi
    Wang, Qi
    Deng, Changming
    Liu, Dichuan
    Yang, Gang
    Jiang, Yonghong
    Wang, Zhibiao
    Huang, Jing
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (10) : 1228 - 1234
  • [6] SYNERGISTIC ABLATION OF LIVER TISSUE AND LIVER CANCER CELLS WITH HIGH-INTENSITY FOCUSED ULTRASOUND AND ETHANOL
    Hoang, Nguyen H.
    Murad, Hakm Y.
    Ratnayaka, Sithira H.
    Chen, Chong
    Khismatullin, Damir B.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (08) : 1869 - 1881
  • [7] Intrapleural Fluid Infusion for MR-Guided High-Intensity Focused Ultrasound Ablation in the Liver Dome
    Wijlemans, Joost W.
    de Greef, Martijn
    Schubert, Gerald
    Moonen, Chrit T. W.
    van den Bosch, Maurice A. A. J.
    Ries, Mario
    ACADEMIC RADIOLOGY, 2014, 21 (12) : 1597 - 1602
  • [8] High-intensity focused ultrasound ablation of uterine localized adenomyosis
    Dong, Xiaojing
    Yang, Zhu
    CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2010, 22 (04) : 326 - 330
  • [9] High-Intensity Focused Ultrasound Ablation of Myocardium In Vivo and Instantaneous Biological Response
    Zheng, Minjuan
    Shentu, Weihui
    Chen, Dingzhang
    Sahn, David J.
    Zhou, Xiaodong
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (09): : 1146 - 1153
  • [10] Microbubbles assist goat liver ablation by high intensity focused ultrasound
    Yu, Tinghe
    Fan, Xionglin
    Xiong, Shuhua
    Hu, Kai
    Wang, Zhibiao
    EUROPEAN RADIOLOGY, 2006, 16 (07) : 1557 - 1563