Machine learning-based treatment couch parameter prediction in support of surface guided radiation therapy

被引:0
作者
De Kerf, Geert [1 ,3 ]
Claessens, Michael [1 ,2 ]
Mollaert, Isabelle [1 ]
Vingerhoed, Wim [1 ]
Verellen, Dirk [1 ,2 ]
机构
[1] Iridium Netwerk, Antwerp, Belgium
[2] Univ Antwerp, Fac Med & Hlth Sci, Dept Radiat Oncol, Antwerp, Belgium
[3] Oosterveldlaan24, B-2610 Antwerp, Belgium
关键词
Machine learning; Quality assurance; Couch position; SGRT; PATIENT SETUP; RADIOTHERAPY;
D O I
10.1016/j.tipsro.2022.08.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A fully independent, machine learning-based automatic treatment couch parameters prediction was developed to support surface guided radiation therapy (SGRT)-based patient positioning protocols. Additionally, this approach also acts as a quality assurance tool for patient positioning. Materials/Methods: Setup data of 183 patients, divided into four different groups based on used setup devices, was used to calculate the difference between the predicted and the acquired treatment couch value. Results: Couch parameters can be predicted with high precision (mu = 0.90, sigma = 0.92). A significant difference (p < 0.01) between the variances of Lung and Brain patients was found. Outliers were not related to the prediction accuracy, but are due to inconsistencies during initial patient setup. Conclusion: Couch parameters can be predicted with high accuracy and can be used as starting point for SGRTbased patient positioning. In case of large deviations (>1.5 cm), patient setup has to be verified to optimally use the surface scanning system.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 15 条
[1]   Can surface imaging improve the patient setup for proton postmastectomy chest wall irradiation? [J].
Batin, Estelle ;
Depauw, Nicolas ;
MacDonald, Shannon ;
Lu, Hsiao-Ming .
PRACTICAL RADIATION ONCOLOGY, 2016, 6 (06) :E235-E241
[2]   Common error pathways seen in the RO-ILS data that demonstrate opportunities for improving treatment safety [J].
Ezzell, Gary ;
Chera, Bhisham ;
Dicker, Adam ;
Ford, Eric ;
Potters, Louis ;
Santanam, Lakshmi ;
Weintraub, Sheri .
PRACTICAL RADIATION ONCOLOGY, 2018, 8 (02) :123-132
[3]   Recent advanced in Surface Guided Radiation Therapy [J].
Freislederer, P. ;
Kugele, M. ;
Ollers, M. ;
Swinnen, A. ;
Sauer, T. -O. ;
Bert, C. ;
Giantsoudi, D. ;
Corradini, S. ;
Batista, V. .
RADIATION ONCOLOGY, 2020, 15 (01)
[4]   Intra-fractional patient motion when using the Qfix Encompass immobilization system during HyperArc treatment of patients with brain metastases [J].
Komiyama, Riho ;
Ohira, Shingo ;
Ueda, Hikari ;
Kanayama, Naoyuki ;
Masaoka, Akira ;
Isono, Masaru ;
Ueda, Yoshihiro ;
Miyazaki, Masayoshi ;
Teshima, Teruki .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03) :254-260
[5]  
Korn M, 2014, PROCEEDINGS OF THE 2014 9TH INTERNATIONAL CONFERENCE ON COMPUTER VISION, THEORY AND APPLICATIONS (VISAPP 2014), VOL 3, P592
[6]   Assessment of Iterative Closest Point Registration Accuracy for Different Phantom Surfaces Captured by an Optical 3D Sensor in Radiotherapy [J].
Krell, Gerald ;
Nezhad, Nazila Saeid ;
Walke, Mathias ;
Al-Hamadi, Ayoub ;
Gademann, Guenther .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2017, 2017
[7]   Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy [J].
Kugele, Malin ;
Mannerberg, Annika ;
Bekke, Susanne Norring ;
Alkner, Sara ;
Berg, Lovisa ;
Mahmood, Faisal ;
Thornberg, Charlotte ;
Edvardsson, Anneli ;
Back, Sven A. J. ;
Behrens, Claus F. ;
Ceberg, Sofie .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09) :61-68
[8]   AlignRT® and Catalyst™ in whole-breast radiotherapy with DIBH: Is IGRT still needed? [J].
Laaksomaa, Marko ;
Sarudis, Sebastian ;
Rossi, Maija ;
Lehtonen, Turkka ;
Pehkonen, Jani ;
Remes, Jenny ;
Luukkanen, Helmi ;
Skytta, Tanja ;
Kapanen, Mika .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (03) :97-104
[9]   Radiotherapy without tattoos: Could this work? [J].
Rigley, J. ;
Robertson, P. ;
Scattergood, L. .
RADIOGRAPHY, 2020, 26 (04) :288-293
[10]   A method to predict patient-specific table coordinates for quality assurance in external beam radiation therapy [J].
Saenz, Daniel L. ;
Astorga, Nestor Rodrigo ;
Kirby, Neil ;
Fakhreddine, Mohamad ;
Rasmussen, Karl ;
Stathakis, Sotirios ;
Papanikolaou, Niko .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05) :625-631