Early experience with a 3-D printed porous surface, fixed-bearing, total ankle arthroplasty: A minimum of 2-year follow-up

被引:1
|
作者
Duff, Joseph [1 ]
Dunson, Jordan [1 ]
Doty, Jesse F. [1 ]
机构
[1] Univ Tennessee, Dept Orthopaed Surg, Coll Med Chattanooga, 975 East Third St,Hosp Box 260, Chattanooga, TN 37403 USA
关键词
Total ankle arthroplasty; 3-D printed design; Implant survivorship; Arthritis; Arthroplasty; PATIENT-REPORTED OUTCOMES; ARTHRODESIS; REPLACEMENT; IMPLANTS; LASER;
D O I
10.1016/j.fas.2024.02.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This is a pilot study reviewing patients undergoing ankle replacement with the 3-D printed INFINITY (TM) with ADAPTIS (TM) total ankle arthroplasty (TAA) system. Methods: A retrospective review was conducted of patients with a minimum two-year follow-up who underwent TAA with the INFINITY (TM) with ADAPTIS (TM) implant system. Outcome measures include implant survivorship, complications with subsequent reoperations, patient reported outcomes, and radiologic subsidence or radiolucency. Results: Thirty patients were included with median follow-up of 26 months (range, 24-36). Implant survival rate was 90% (27/30). Two patients experienced linear radiolucency > 2 mm: one required a revision TAA secondary to tibial subsidence; the other patient was asymptomatic and nonprogressive on serial radiographs. No cystic radiolucencies > 5 mm were identified. VAS, PROMIS PF, and FADI scores improved significantly. Conclusion: TAA performed with the 3-D printed INFINITY (TM) with ADAPTIS (TM) implant technology led to ninety percent short term implant survivorship and improvement in patient reported outcomes with comparable results to other 4th generation arthroplasty systems as a treatment modality for end-stage ankle arthritis. Level of evidence: Level III, Retrospective cohort study, Prognostic (c) 2024 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:382 / 388
页数:7
相关论文
共 50 条
  • [21] A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients
    Xiao Geng
    Yang Li
    Feng Li
    Xinguang Wang
    Ke Zhang
    Zhongjun Liu
    Hua Tian
    Journal of Orthopaedic Surgery and Research, 15
  • [22] Femoro Patella Vialla patellofemoral arthroplasty: An independent assessment of outcomes at minimum 2-year follow-up
    Halai, Mansur
    Ker, Andrew
    Anthony, Iain
    Holt, Graeme
    Jones, Bryn
    Blyth, Mark
    WORLD JOURNAL OF ORTHOPEDICS, 2016, 7 (08): : 487 - 493
  • [23] Preliminary outcomes of the cementless UNITED hip system for primary total hip arthroplasty at a minimum 2-year follow-up
    Diaz-Dilernia, Fernando
    Garcia-Mansilla, Agustin M.
    Albani-Forneris, Agustin
    Slullitel, Pablo A.
    Zanotti, Gerardo
    Comba, Fernando
    Piccaluga, Francisco
    Buttaro, Martin
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (04) : 745 - 752
  • [24] A Playtime and Handicap Analysis of 143 Regular Golfers After Total Knee Arthroplasty at Minimum 2-Year Follow-Up
    Pioger, Charles
    Bellity, Jonathan P.
    Simon, Raphael
    Rouillon, Olivier
    Smith, Belinda J.
    Nizard, Remy
    JOURNAL OF ARTHROPLASTY, 2020, 35 (05) : 1257 - 1261
  • [25] Preformed Articulating Knee Spacers in 2-Stage Total Knee Revision Arthroplasty Minimum 2-Year Follow-Up
    Wan, Zhinian
    Momaya, Amit
    Karim, Azim
    Incavo, Stephen J.
    Mathis, Kenneth B.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08) : 1469 - 1473
  • [26] Clinical and radiologic outcomes of Lima ProMade custom 3D-printed glenoid components in primary and revision reverse total shoulder arthroplasty with severe glenoid bone loss: a minimum 2-year follow-up
    Rashid, Mustafa S.
    Cunningham, Lindsay
    Shields, David W.
    Walton, Michael J.
    Monga, Puneet
    Bale, Richard S.
    Trail, Ian A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (10) : 2017 - 2026
  • [27] Early Debris Formation with a Porous Tantalum Glenoid Component Radiographic Analysis with 2-Year Minimum Follow-up
    Endrizzi, Donald P.
    Mackenzie, Johanna A.
    Henry, Patrick D. G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (12) : 1023 - 1029
  • [28] Early experience with the NexGen((R)) CR-Flex Mobile knee arthroplasty system: results of 2-year follow-up
    Endres, Stefan
    Wilke, Axel
    ORTHOPEDIC REVIEWS, 2010, 2 (01) : 3 - 5
  • [29] Fixed-bearing posterior-stabilized implant versus constrained condylar knee in one-stage bilateral primary arthroplasty of the varus knee: A randomized controlled trial with minimum 2-year follow-up
    Sarzaeem, Mohammad Mahdi
    Sayyadi, Shahram
    Pourmojarab, Ali
    Omidian, Mohammad Mahdi
    Lemraski, Mohammad Mahdi Bagherian
    Baroutkoub, Mojtaba
    Salimi, Sohrab
    Rasi, Alireza Manafi
    ADVANCED BIOMEDICAL RESEARCH, 2022, 11 (01): : 34
  • [30] Survivorship of the fixed-bearing medial unicompartmental knee arthroplasty: mean 14-year follow-up in a single medical center
    Hung, Kung-Tseng
    Chen, Chun-Chieh
    Lin, Yu-Chih
    Lee, Sheng-Hsun
    Hu, Chih-Chien
    Chang, Yu-Han
    Hsieh, Pang-Hsin
    Shih, Hsin-Nung
    Chang, Chih-Hsiang
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)