Experimental and numerical study during the solidification process of a vertical and horizontal coiled ice storage system

被引:7
|
作者
Chang, Chun [1 ,2 ,3 ]
Xu, Xiaoyu [1 ,2 ]
Guo, Xinxin [2 ,3 ]
Yu, Rong [1 ]
Rasakhodzhaev, Bakhramzhan [4 ]
Bao, Daorina [1 ]
Zhao, Mingzhi [1 ]
机构
[1] Inner Mongolia Univ Technol, Hohhot 010051, Peoples R China
[2] Inst Elect Engn, Chinese Acad Sci, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Minist Energy Uzbekistan, Natl Res Inst Renewable Energy Sources, Tashkent City, Uzbekistan
基金
国家重点研发计划; 欧盟地平线“2020”;
关键词
energy storage; ice storage; Air conditioning technology; Natural convection; vertical; horizontal; THERMAL-ENERGY STORAGE; OPTIMAL-DESIGN; PCM; MODEL; TANK; OPTIMIZATION; PERFORMANCE; CFD;
D O I
10.1016/j.energy.2024.131325
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy storage technology provides a solution to the contradiction between energy supply and demand, as well as the volatility and intermittency of renewable energy. As a representative energy storage system, the coil type energy storage system is of great significance in improving the reliability and cooling economy of building cooling systems. The configuration of coils has a significant impact on the ice storage process and icing rate. This study deals with the experimental and numerical analysis of the influence of different configurations on solidification process. The natural convection and density reversal at 277.15K of water have a significant impact during the cooling process. Therefore, we divide the cooling stage of water into two stages: 283.15K - 277.15K and 277.15K - 273.15K. Due to natural convection and density reversal of the cooling process, the thickness of the ice layer on the outer surfaces of the upper and lower sides varies unevenly in the horizontal configuration. The phenomenon where the ice layer in the vertical configuration is distributed conical, and the ice layer at the bottom is thinner than the ice layer at the top. As the ice storage process progresses, natural convection decreases from 1.5 x 10 -2 m/s to 2.9 x 10 -4 m/s. Within 210 min, the thickness of the ice layer in the vertical configuration is 2.27 mm thicker than that in the horizontal configuration. This article aims to study the effects of natural convection and density reversal during ice storage, explore the ice storage rate under horizontal and vertical placement, and provide reference value for practical engineering. To be conclusive, the ice storage rate of the vertical configuration increased by 13.33 % compared to the horizontal configuration.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Numerical and Experimental Study on a High-Power Cold Achieving Process of a Coil-Plate Ice-Storage System
    Guo, Liang
    Ye, Hong
    ENERGIES, 2019, 12 (21)
  • [22] Experimental and numerical characterization of natural convection in a vertical shell-and-tube latent thermal energy storage system
    Seddegh, Saeid
    Joybari, Mahmood Mastani
    Wang, Xiaolin
    Haghighat, Fariborz
    SUSTAINABLE CITIES AND SOCIETY, 2017, 35 : 13 - 24
  • [23] Experimental and numerical study of a vertical earth-to-air heat exchanger system integrated with annular phase change material
    Liu, Zhengxuan
    Yu, Zhun
    Yang, Tingting
    El Mankibi, Mohamed
    Roccamena, Letizia
    Sun, Ying
    Sun, Pengcheng
    Li, Shuisheng
    Zhang, Guoqiang
    ENERGY CONVERSION AND MANAGEMENT, 2019, 186 : 433 - 449
  • [24] Experimental and numerical study on charging processes of an ice-on-coil thermal energy storage system
    Erek, Aytunc
    Ezan, Mehmet Akif
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (02) : 158 - 176
  • [25] Study on the effect of partial filling of foam metal on the solidification performance of ice storage spheres
    Wang, Hui
    Ying, Qifan
    Chen, Wenmin
    Diao, Yongfa
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 158 : 365 - 377
  • [26] Thermal analysis of latent heat storage system in vertical and horizontal configurations under simultaneous charging and discharging processes
    Khobragade, Sandip
    Devanuri, Jaya Krishna
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 36
  • [27] Experimental and numerical study on the performance and thermal storage application of SAT/CPCM
    Yu, Qiang
    Xu, Xiaoyu
    Zhang, Gaocheng
    Tan, Yilin
    Shi, Bingyan
    Xiong, Xinyu
    Zhang, Shiman
    Wu, Zhiyong
    JOURNAL OF ENERGY STORAGE, 2025, 118
  • [28] An experimental and numerical study on effect of longitudinal finned tube eccentric configuration on melting behaviour of lauric acid in a horizontal tube-in-shell storage unit
    Kumar, Rishav
    Verma, Prashant
    JOURNAL OF ENERGY STORAGE, 2020, 30
  • [29] Experimental and numerical analysis of paraffin waxes during solidification inside spherical capsules
    Ismail, Mohammad
    Alkhazaleh, Awni H.
    Masri, Jafar
    Ali, Abdullah Masoud
    Ali, Malek
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 26
  • [30] Numerical and experimental study of heat transfer characteristics of a shell-tube latent heat storage system: Part I - Charging process
    Xiao, X.
    Zhang, P.
    ENERGY, 2015, 79 : 337 - 350