Influence of the liquid ionic strength on the resonance frequency and shell parameters of lipid-coated microbubbles

被引:4
|
作者
Sojahrood, A. J. [1 ,2 ,3 ]
Yang, C. [2 ,3 ]
Counil, C. [4 ]
Nittayacharn, P. [4 ,5 ]
Goertz, D. E. [1 ,6 ]
Exner, A. A. [4 ]
Kolios, M. C. [2 ,3 ]
机构
[1] Sunnybrook Res Inst, Toronto, ON, Canada
[2] Toronto Metropolitan Univ, Dept Phys, Toronto, ON, Canada
[3] Inst Biomed Engn Sci & Technol iBEST, Toronto, ON, Canada
[4] Case Western Univ, Dept Biomed Engn, Cleveland, OH USA
[5] Mahidol Univ, Fac Engn, Dept Biomed Engn, Puttamonthon, Nakorn Pathom, Thailand
[6] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会; 美国国家卫生研究院;
关键词
ULTRASOUND CONTRAST AGENTS; RADIAL PULSATIONS; SIZE DISTRIBUTION; MAGNETIC-FIELD; GAS-BUBBLES; TEMPERATURE; ATTENUATION; STABILITY; MONODISPERSE; OSCILLATIONS;
D O I
10.1016/j.jcis.2024.01.185
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The correct measurement of the resonance frequency and shell properties of coated microbubbles (MBs) is essential in understanding and optimizing their response to ultrasound (US) exposure parameters. In diagnostic and therapeutic ultrasound, MBs are typically surrounded by blood; however, the influence of the medium charges on the MB resonance frequency has not been systematically studied using controlled measurements. This study aims to measure the medium charge interactions on MB behavior by measuring the frequency-dependent attenuation of the same size MBs in mediums with different charge densities. In-house lipid-coated MBs with C3F8 gas core were formulated. The MBs were isolated to a mean size of 2.35 mu m using differential centrifugation. MBs were diluted to approximate to 8x10 5 MBs/mL in distilled water (DW), Phosphate-Buffered Saline solution (PBS1x) and PBS10x. The frequency-dependent attenuation of the MBs solutions was measured using an aligned pair of PVDF transducers with a center frequency of 10MHz and 100% bandwidth in the linear oscillation regime (7 kPa pressure amplitude). The MB shell properties were estimated by fitting the linear equation to experiments. Using a pendant drop tension meter, the surface tension at the equilibrium of approximate to 6mm diameter size drops of the same MB shell was measured inside DW, PBS1x and PBS10x. The surface tension at the C3F8/solution interface was estimated by fitting the Young-Laplace equation from the recorded images. The frequency of the peak attenuation at different salinity levels was 13, 7.5 and 6.25 MHz in DW, PBS1x and PBS-10x, respectively. The attenuation peak increased by approximate to 140% with increasing ion density. MBs' estimated shell elasticity decreased by 64% between DW and PBS-1x and 36% between PBS-1x and PBS-10x. The drop surface tension reduced by 10.5% between DW and PBS-1x and by 5% between PBS-1x and PBS-10x, respectively. Reduction in the shell stiffness is consistent with the drop surface tension measurements. The shell viscosity was reduced by approximate to 40% between DW and PBS-1x and 42% between PBS-1x and PBS-10x. The reduction in the fitted stiffness and viscosity is possibly due to the formation of a densely charged layer around the shell, further reducing the effective surface tension on the MBs. The changes in the resonance frequency and estimated shell parameters were significant and may potentially help to better understand and explain bubble behavior in applications.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 50 条
  • [21] The affinity of lipid-coated microbubbles for maturing brain injury sites
    Ho, SY
    Li, XG
    Wakefield, A
    Barbarese, E
    DArrigo, JS
    Simon, RH
    BRAIN RESEARCH BULLETIN, 1997, 43 (06) : 543 - 549
  • [22] Development of a Novel Magnetic Resonance Imaging Contrast Agent for Pressure Measurements Using Lipid-Coated Microbubbles
    Kaur, Randip
    Morris, Robert
    Bencsik, Martin
    Vangala, Anil
    Rades, Thomas
    Perrie, Yvonne
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2009, 5 (06) : 707 - 715
  • [23] The affinity of lipid-coated microbubbles to maturing spinal cord injury sites
    Kureshi, IU
    Ho, SY
    Onyiuke, HC
    Wakefield, AE
    Kureshi, IU
    D'Arrigo, JS
    Simon, RH
    NEUROSURGERY, 1999, 44 (05) : 1047 - 1053
  • [24] DSPC or DPPC as main shell component influences ligand distribution and binding area of lipid-coated targeted microbubbles
    Kooiman, Klazina
    Kokhuis, Tom J. A.
    van Rooij, Tom
    Skachkov, Ilya
    Nigg, Alex
    Bosch, Johannes G.
    van der Steen, Antonius F. W.
    van Cappellen, Wiggert A.
    de Jong, Nico
    EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY, 2014, 116 (09) : 1217 - 1227
  • [25] Vibrational Responses of Bound and Nonbound Targeted Lipid-Coated Single Microbubbles
    van Rooij, Tom
    Beekers, Ines
    Lattwein, Kirby R.
    van der Steen, Antonius F. W.
    de Jong, Nico
    Kooiman, Klazina
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (05) : 785 - 797
  • [26] MODELLING LIPID-COATED MICROBUBBLES IN FOCUSED ULTRASOUND APPLICATIONS AT SUBRESONANCE FREQUENCIES
    Guemmer, Jonas
    Schenke, Soeren
    Denner, Fabian
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (10): : 2958 - 2979
  • [27] Evaluation of lipid-coated microbubbles as a delivery vehicle for taxol in brain tumor therapy
    Ho, SY
    Barbarese, E
    DArrigo, JS
    SmithSlatas, C
    Simon, RH
    NEUROSURGERY, 1997, 40 (06) : 1260 - 1266
  • [29] Investigating the potential of gas-filled lipid-coated microbubbles as vaccine adjuvants
    Kaur, R.
    Morris, R.
    Bencsik, M.
    Vangala, A.
    Rades, T.
    Perrie, Y.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2009, 61 : A44 - A44
  • [30] DNA and polylysine adsorption and multilayer construction onto cationic lipid-coated microbubbles
    Borden, Mark A.
    Caskey, Charles F.
    Little, Erika
    Gillies, Robert J.
    Ferrara, Katherine W.
    LANGMUIR, 2007, 23 (18) : 9401 - 9408