Body Core Temperature Assessment in Emergency Care Departments

被引:1
作者
Daanen, Hein A. M. [1 ]
Hoitinga, Gercora [2 ]
Kruijt, David J. [2 ]
Koning, Kevin S. [1 ]
Verheijen, Pooh P. [1 ]
de Baas, Sanne I. M. [1 ]
Bergsma, Anouk R. [1 ]
Snethlage, Cathelijne E. [1 ]
Al -Bander, Iman [1 ]
Teunissen, Lennart P. J. [3 ]
机构
[1] Vrije Univ Amsterdam, Fac Behav & Movement Sci, Dept Human Movement Sci, Amsterdam Movement Sci, Boechorststr 7, NL-1081 BT Amsterdam, Netherlands
[2] Univ Amsterdam, Dept Emergency Med, Amsterdam UMC, Amsterdam, Netherlands
[3] Minist Def, Dept Training Med & Training Physiol, Royal Netherlands Army, Utrecht, Netherlands
关键词
thermometry; tympanic temperature; fever; arteria temporalis; thermometer; exercise; calibration; RELIABILITY; ACCURACY; VALIDITY; SKIN; THERMOMETERS;
D O I
10.1016/j.jemermed.2023.10.027
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: There is concern that the values provided by devices using infrared thermometry in emergency departments (EDs) do not reflect body core temperature accurately. Objectives: Evaluation of three thermometers commonly used in the ED. Methods: Two infrared ear thermometers and an infrared forehead thermometer were evaluated using 1) the Voltcraft IRS -350 calibration device, 2) comparing temperature values to a rectal end -exercise temperature (T-RECT) of 38.1 degrees C in 12 participants, and 3) comparing temperature values to rectal temperature in 133 ED patients. Results: Calibration across the human core temperature range revealed that the ear thermometers underestimated radiant temperature by 0.77 +/- 0.39 degrees C and 1.84 +/- 0.26 degrees C, respectively, whereas the forehead thermometer overestimated radiant temperature by 0.90 +/- 0.51 degrees C. After cycling exercise, all thermometers underestimated T-RECT (0.54 +/- 0.27 degrees C and 1.03 +/- 0.48 degrees C for the ear thermometers and 1.14 +/- 0.38 degrees C for the forehead thermometer). In the ED, the ear thermometers underestimated T-RECT by 0.31 +/- 0.37 degrees C and 0.46 +/- 0.50 degrees C, whereas the forehead thermometer exhibited a nonsignificant overestimation of 0.04 +/- 0.46 degrees C. If the threshold for fever in all systems had been set to 37.5 degrees C instead of 38.0 degrees C, the sensitivity and specificity of the systems for real fever (T-RECT >= 38 degrees C) are, respectively, 71% and 96% (ear thermometer 1), 57% and 97% (ear thermometer 2), and 86% and 90% (forehead thermometer). Conclusion: We conclude that the investigated thermometers are not reliable as devices to measure radiant temperature, cannot be used to assess body core temperature during exercise, but may be used as a screening device, with 37.5 degrees C as a threshold for fever in emergency care settings. (c) 2023 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ )
引用
收藏
页码:e277 / e283
页数:7
相关论文
共 29 条
  • [21] Infrared ear thermometers - parameters influencing their reading and accuracy
    Pusnik, I
    Drnovsek, J
    [J]. PHYSIOLOGICAL MEASUREMENT, 2005, 26 (06) : 1075 - 1084
  • [22] Agreement between rectal and tympanic membrane temperatures in marathon runners
    Roth, RN
    Verdile, VP
    Grollman, LJ
    Stone, DA
    [J]. ANNALS OF EMERGENCY MEDICINE, 1996, 28 (04) : 414 - 417
  • [23] Temperature monitoring and perioperative thermoregulation
    Sessler, Daniel I.
    [J]. ANESTHESIOLOGY, 2008, 109 (02) : 318 - 338
  • [24] Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique
    Simpson, CR
    Kohl, M
    Essenpreis, M
    Cope, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (09) : 2465 - 2478
  • [25] Accuracy of infrared ear thermometry in adult patients
    Stavem, K
    Saxholm, H
    SmithErichsen, N
    [J]. INTENSIVE CARE MEDICINE, 1997, 23 (01) : 100 - 105
  • [26] SPECTRAL EMISSIVITY OF SKIN AND PERICARDIUM
    STEKETEE, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (05) : 686 - 694
  • [27] Teunissen L. P. J., 2011, Journal of Medical Engineering & Technology, V35, P134, DOI 10.3109/03091902.2011.554595
  • [28] TIBCO Software Inc, 2020, Data Science Workbench
  • [29] Temperature measurement
    Wartzek, Tobias
    Muehlsteff, Jens
    Imhoff, Michael
    [J]. BIOMEDIZINISCHE TECHNIK, 2011, 56 (05): : 241 - 257