Surgical approaches to correct corneal astigmatism at time of cataract surgery: a mini-review

被引:0
作者
Yin, Xiao-Lei [1 ]
Ji, Zhi-Yang [2 ]
Li, Xiu-Xin [1 ]
Liang, Xue-Mei [3 ]
Ji, Shu-Xing [2 ]
机构
[1] 305 Hosp PLA, Dept Ophthalmol, Beijing 100017, Peoples R China
[2] Army Med Univ, Daping Hosp, Dept Ophthalmol, Chongqing 400042, Peoples R China
[3] 305 Hosp PLA, Dept Med Adm, Beijing 100017, Peoples R China
关键词
cornea; astigmatism; cataract surgery; peripheral corneal relaxing incisions; toric intraocular lens; TORIC INTRAOCULAR LENSES; TEMPORAL CLEAR CORNEAL; INCISION; PHACOEMULSIFICATION; SUPERIOR; OUTCOMES;
D O I
10.18240/ijo.2024.07.23
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Among refractive errors, astigmatism is the most common optical aberration, where refraction changes in different meridians of the eye. It causes blurred vision at any distance and includes corneal, lenticular, and retinal astigmatism. Cataract surgery used to cause a progressive increase in the pre-exisiting corneal astigmatism because of creating a surgically induced astigmatism, for example, a large size surgery incision. The development of surgical techniques during last decades has made cataract surgery interchange to treat preoperative corneal astigmatism at time of surgery. Nowadays, three surgical approaches can be used. By placing a sutureless clear corneal incision on the steep meridian of the cornea, a preoperative corneal astigmatism less than 1.0 D can be corrected. Single or paired peripheral corneal relaxing incisions (PCRIs) provide 1.0-3.0 D corneal astigmatism correction. PCRIs are typically used for treating 1.0-1.5 D of regular corneal astigmatism, if more than 2.0 D, the risk of overcorrection and irregular astigmatism is increased. When toric intraocular lenses (IOLs) are unavailable in markets, PCRIs are still a reasonable option for patients with up to 3.0 D of pre-existing corneal astigmatism. Toric IOLs implantation can correct 1.0-4.5 D of corneal astigmatism. Several IOLs are approved to correct a high degree of corneal astigmatism with cylinder power up to 12.0 D. These approaches can be used alone or in combination.
引用
收藏
页码:1370 / 1374
页数:5
相关论文
共 38 条
  • [1] Do limbal relaxing incisions during cataract surgery still have a role?
    Abu-Ain, Mohammad Saleh
    Al-latayfeh, Motasem Mohammad
    Khan, Mohammad Irfan
    [J]. BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [2] Correction of astigmatism at the time of cataract surgery
    Amesbury, Eric C.
    Miller, Kevin M.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (01) : 19 - 24
  • [3] Analysis of biometric parameters of cataract eyes measured with optical biometer Lenstar LS900, IOL Master 700, and OPD-SCAN III
    Bao, Tong
    Wang, Lifeng
    Liu, Caihui
    Yang, Yajun
    Pang, Yunlei
    [J]. PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 43
  • [4] Astigmatism outcomes of horizontal temporal versus nasal dear corneal incision cataract surgery
    Barequet, IS
    Yu, E
    Vitale, S
    Cassard, S
    Azar, DT
    Stark, WJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) : 418 - 423
  • [5] Corneal astigmatism after phacoemulsification and lens implantation through unsutured scleral and corneal tunnel incisions
    Gross, RH
    Miller, KM
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 121 (01) : 57 - 64
  • [6] The location of incision in cataract surgery and its impact on induced astigmatism
    Hashemi, Hassan
    Khabazkhoob, Mehdi
    Soroush, Sara
    Shariati, Reyhane
    Miraftab, Mohammad
    Yekta, Abbasali
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (01) : 58 - 64
  • [7] Postoperative corneal shape changes: Microincision versus small-incision coaxial cataract surgery
    Hayashi, Ken
    Yoshida, Motoaki
    Hayashi, Hideyuki
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02) : 233 - 239
  • [8] Repositioning Rates of Toric IOLs Implanted in Cataract Surgery Patients: A Retrospective Chart Review
    Hu, Edward H.
    [J]. CLINICAL OPHTHALMOLOGY, 2023, 17 : 4001 - 4007
  • [9] Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients
    Hu, Zun-Xia
    Sima, Jing
    Cao, Jia-Guo
    Ke, Yan
    Zhang, Ying-Ying
    Guo, Qiong-Tian
    He, Yu-Ping
    Liao, Hong-Xia
    Tan, Xiao
    Qin, Bo
    Li, Li
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2023, 16 (12) : 1996 - 2003
  • [10] A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients
    Jiang, Jianhong
    Pan, Xiaojing
    Zhou, Mingming
    Wang, Xiaoyun
    Zhu, Hai
    Li, Dongfang
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)