Optical Coherence Tomography based on Dynamic Changes in Light Field Amplitude for Functional Imaging (Invited)

被引:0
|
作者
Yang Jianlong [1 ]
Zhang Haoran [1 ]
Liu Chang [1 ]
Gu Chengfu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai 200240, Shanghai, Peoples R China
关键词
optical coherence tomography; functional imaging; dynamic change of light field amplitude; dynamic light scattering; COMPLEX DIFFERENTIAL VARIANCE; EYE MOTION CORRECTION; BLOOD-FLOW VELOCITY; OCT ANGIOGRAPHY; WIDE-FIELD; AUTOMATIC SEGMENTATION; HUMAN RETINA; SCATTERING; CONTRAST; ELASTOGRAPHY;
D O I
10.3788/LOP232021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Optical coherence tomography (OCT) can nondestructively obtain the cross- sectional information of samples at micron-level spatial resolution, which is important for ophthalmology and endovascular medicine. The OCT amplitude provides three-dimensional (3D) structural information of a sample ( for example, the layered structure of the retina) but is of limited use for obtaining functional information such as tissue specificity, blood flow, and mechanical properties. Functional OCT imaging techniques based on other optical field properties, including phase, polarization state, and wavelength, have also emerged. Among these techniques, Doppler OCT, optical coherence elastography, polarization-sensitive OCT, and visible- light OCT, based on dynamic changes in the light-field amplitude, are robust, uncomplicated, and have achieved high clinical success in label-free blood flow imaging. In addition, dynamic light scattering OCT for 3D blood flow velocity measurement, dynamic OCT with the ability to display label-free tissue/cell specificity, and OCT thermometry for monitoring the temperature field of thermophysical treatments are the frontiers in OCT functional imaging. This paper summarizes the principles and applications of the above technologies, analyzes the remaining technical challenges, and envisions the future development of OCT functional imaging.
引用
收藏
页数:16
相关论文
共 136 条
  • [1] Dynamic full field optical coherence tomography: subcellular metabolic contrast revealed in tissues by interferometric signals temporal analysis
    Apelian, Clement
    Harms, Fabrice
    Thouvenin, Olivier
    Boccara, A. Claude
    [J]. BIOMEDICAL OPTICS EXPRESS, 2016, 7 (04): : 1511 - 1524
  • [2] Optical coherence tomography in coronary atherosclerosis assessment and intervention
    Araki, Makoto
    Park, Seung-Jung
    Dauerman, Harold L.
    Uemura, Shiro
    Kim, Jung-Sun
    Di Mario, Carlo
    Johnson, Thomas W.
    Guagliumi, Giulio
    Kastrati, Adnan
    Joner, Michael
    Holm, Niels Ramsing
    Alfonso, Fernando
    Wijns, William
    Adriaenssens, Tom
    Nef, Holger
    Rioufol, Gilles
    Amabile, Nicolas
    Souteyrand, Geraud
    Meneveau, Nicolas
    Gerbaud, Edouard
    Opolski, Maksymilian P.
    Gonzalo, Nieves
    Tearney, Guillermo J.
    Bouma, Brett
    Aguirre, Aaron D.
    Mintz, Gary S.
    Stone, Gregg W.
    Bourantas, Christos, V
    Raber, Lorenz
    Gili, Sebastiano
    Mizuno, Kyoichi
    Kimura, Shigeki
    Shinke, Toshiro
    Hong, Myeong-Ki
    Jang, Yangsoo
    Cho, Jin Man
    Yan, Bryan P.
    Porto, Italo
    Niccoli, Giampaolo
    Montone, Rocco A.
    Thondapu, Vikas
    Papafaklis, Michail, I
    Michalis, Lampros K.
    Reynolds, Harmony
    Saw, Jacqueline
    Libby, Peter
    Weisz, Giora
    Iannaccone, Mario
    Gori, Tommaso
    Toutouzas, Konstantinos
    [J]. NATURE REVIEWS CARDIOLOGY, 2022, 19 (10) : 684 - 703
  • [3] Dynamic optical coherence tomography for cell analysis [Invited]
    Azzollini, Salvatore
    Monfort, Tual
    Thouvenin, Olivier
    Grieve, Kate
    [J]. BIOMEDICAL OPTICS EXPRESS, 2023, 14 (07) : 3362 - 3379
  • [4] Bille J.F., 2019, High resolution imaging in microscopy and ophthalmology: new frontiers in biomedical optics
  • [5] SCATTERING AND IMAGING WITH DIFFUSING TEMPORAL FIELD CORRELATIONS
    BOAS, DA
    CAMPBELL, LE
    YODH, AG
    [J]. PHYSICAL REVIEW LETTERS, 1995, 75 (09) : 1855 - 1858
  • [6] Bouma BE, 2022, NAT REV METHOD PRIME, V2, DOI 10.1038/s43586-022-00162-2
  • [7] Real-time eye motion correction in phase-resolved OCT angiography with tracking SLO
    Braaf, Boy
    Vienola, Kari V.
    Sheehy, Christy K.
    Yang, Qiang
    Vermeer, Koenraad A.
    Tiruveedhula, Pavan
    Arathorn, David W.
    Roorda, Austin
    de Boer, Johannes F.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2013, 4 (01): : 51 - 65
  • [8] Noise characterization of supercontinuum sources for low-coherence interferometry applications
    Brown, William J.
    Kim, Sanghoon
    Wax, Adam
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2014, 31 (12) : 2703 - 2710
  • [9] BURCHARD W, 1983, ADV POLYM SCI, V48, P1
  • [10] The mechanoelectrical transducer channel is not required for regulation of cochlear blood flow during loud sound exposure in mice
    Burwood, George W. S.
    Dziennis, Suzan
    Wilson, Teresa
    Foster, Sarah
    Zhang, Yuan
    Liu, Gangjun
    Yang, Jianlong
    Elkins, Sean
    Nuttall, Alfred L.
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)