Biosensors play an important role in numerous research fields. Quartz crystal microbalances with dissipation monitoring (QCM-Ds) are sensitive devices, and binding events can be observed in real-time. In combination with aptamers, they have great potential for selective and label-free detection of various targets. In this study, an alternative surface functionalization for a QCM-D-based aptasensor was developed, which mimics an artificial cell membrane and thus creates a physiologically close environment for the binding of the target to the sensor. Vesicle spreading was used to form a supported lipid bilayer (SLB) of 1-palmitoyl-2-oleoyl-glycero-3-phosphocholine (POPC) and 1,2-dipalmitoyl-sn-glycero-3-phosphethanolamine-N-(cap biotinyl) (biotin-PE). The SLB was then coated with streptavidin followed by applying a biotinylated aptamer against thrombin. SLB formation was investigated in terms of temperature and composition. Temperatures of 25 degrees C and below led to incomplete SLB formation, whereas a full bilayer was built at higher temperatures. We observed only a small influence of the content of biotinylated lipids in the mixture on the further binding of streptavidin. The functionalization of the sensor surface with the thrombin aptamer and the subsequent thrombin binding were investigated at different concentrations. The sensor could be reconstituted by incubation with a 5 M urea solution, which resulted in the release of the thrombin from the sensor surface. Thereafter, it was possible to rebind thrombin. Thrombin in spiked samples of human serum was successfully detected. The developed system can be easily applied to other target analytes using the desired aptamers.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] An aptamer-based biosensor for sensitive thrombin detection
    Yang, Hui
    Ji, Ji
    Liu, Yun
    Kong, Jilie
    Liu, Baohong
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (01) : 38 - 40
  • [2] DNA aptamer-based QDs electrochemiluminescence biosensor for the detection of thrombin
    Huang, Haiping
    Zhu, Jun-Jie
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04): : 927 - 930
  • [3] Development of a QCM-D biosensor for Ochratoxin A detection in red wine
    Karczmarczyk, Aleksandra
    Haupt, Karsten
    Feller, Karl-Heinz
    TALANTA, 2017, 166 : 193 - 197
  • [4] Detection of Thrombin with an Aptamer-Based Macromolecule Biosensor Using Bacterial Ghost System
    Wang, Jiasheng
    Ding, Ke
    Chen, Yujie
    Zhang, Lifeng
    Liu, Zukai
    Xue, Angli
    Gu, Wenjia
    Yang, Xiaoyue
    Li, Xihan
    Huang, Jin
    Xing, Congcong
    Cao, Yunlong
    Chen, Ming
    ACS SYNTHETIC BIOLOGY, 2014, 3 (12): : 963 - 965
  • [5] The interaction of cubosomes with supported phospholipid bilayers using neutron reflectometry and QCM-D
    Shen, Hsin-Hui
    Hartley, Patrick G.
    James, Michael
    Nelson, Andrew
    Defendi, Hugo
    McLean, Keith M.
    SOFT MATTER, 2011, 7 (18) : 8041 - 8049
  • [6] Amplified QCM-D biosensor for protein based on aptamer-functionalized gold nanoparticles
    Chen, Qiang
    Tang, Wei
    Wang, Dingzhong
    Wu, Xiaojie
    Li, Na
    Liu, Feng
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 575 - 579
  • [7] Following the formation of supported lipid bilayers on mica: A study combining AFM, QCM-D, and ellipsometry
    Richter, RP
    Brisson, AR
    BIOPHYSICAL JOURNAL, 2005, 88 (05) : 3422 - 3433
  • [8] Aptamer-Based Surface Plasmon Fibre Sensor for Thrombin Detection
    Allsop, T.
    Nagel, D.
    Neal, R.
    Davies, E. M.
    Mou, C.
    Bond, P.
    Rehman, S.
    Kalli, K.
    Webb, D. J.
    Calverhouse, P.
    Mascini, M.
    Bennion, I.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE II, 2010, 7715
  • [9] Measuring the layer of hydration at the membrane-support interface in solid supported lipid bilayers using DPI and QCM-D
    Zwang, Theodore J.
    Fletcher, Will R.
    Lane, Thomas J.
    Johal, Malkiat
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [10] Aptamer-based electrochemical biosensor for label-free voltammetric detection of thrombin and adenosine
    Yan, Fangfang
    Wang, Fang
    Chen, Zilin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) : 1380 - 1385