Axial performance of concrete-filled GFRP tube columns jacketed by outer stainless steel tube and sandwiched concrete

被引:3
作者
Huang, Yue [1 ]
Lu, Yiyan [1 ]
Wang, Pengpeng [1 ]
Li, Shan [1 ]
Jiao, Yifan [1 ]
机构
[1] Wuhan Univ, Sch Civil Engn, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Strengthening; CFFT column; External stainless steel tube; Axial compression; STRESS-STRAIN MODEL; SQUARE COLUMNS; BEHAVIOR; DESIGN; BEAMS;
D O I
10.1016/j.engstruct.2024.118401
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The concrete-filled FRP tube (CFFT) column, a prevalent and crucial structural element in marine environments, requires reinforcement measures to enhance its operational performance. This paper introduces a novel strengthening technology involving sandwiched concrete and stainless steel tube jackets. By conducting axial compression tests on two CFFT columns and nine reinforced columns, the failure modes, load-axial deformation curves, and load-strain relationships were analysed in this study. Additionally, the influence of outer steel tube thickness (3.0 mm, 4.0 mm, 5.0 mm) and sandwiched concrete strength grades (C50, C60, C70) on the axial compressive performance of the reinforced columns was investigated. The findings indicated that the proposed reinforcement method effectively mitigated the brittle failure associated with the original CFFT column. The external stainless steel tube played a crucial role in restraining lateral deformation of the internal CFFT column, thereby enhancing the axial compressive bearing capacity. Through theoretical analysis on the components in reinforced columns, a calculation formula for the axial compressive capacity of the reinforced column was derived according to the unified theory and the double-shear unified strength theory.
引用
收藏
页数:13
相关论文
共 43 条
  • [1] Structural applications of fibre reinforced polymer (FRP) composite tubes: A review of columns members
    Al-saadi, Ali Umran
    Aravinthan, Thiru
    Lokuge, Weena
    [J]. COMPOSITE STRUCTURES, 2018, 204 : 513 - 524
  • [2] RETRACTED: Repair of Buckled Concrete Filled Steel Tube Columns Subjected to Axial Compression (Retracted Article)
    Almasslawi, Ahmed
    Ekmekyapar, Talha
    AL-Eliwi, Baraa J. M.
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2020, 24 (05) : 1499 - 1508
  • [3] [Anonymous], 2008, GB/T 1458
  • [4] Strengthening of shear critical RC beams with various FRP systems
    Baggio, Daniel
    Soudki, Khaled
    Noel, Martin
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2014, 66 : 634 - 644
  • [5] Hybrid fibre reinforced polymer and seawater sea sand concrete structures: A systematic review on short-term and long-term structural performance
    Bazli, Milad
    Heitzmann, Michael
    Hernandez, Byron Villacorta
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2021, 301
  • [6] Cai S.H., 2003, MODERN STEEL TUBE CO
  • [7] Shear capacity of fiber-reinforced polymer-strengthened reinforced concrete beams: Fiber reinforced polymer rupture
    Chen, JF
    Teng, JG
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2003, 129 (05) : 615 - 625
  • [8] Corner strengthening of square and rectangular concrete-filled FRP tubes
    Chen, Linpeng
    Ozbakkaloglu, Togay
    [J]. ENGINEERING STRUCTURES, 2016, 117 : 486 - 495
  • [9] Design of robust and ductile FRP structures incorporating ductile adhesive joints
    de Castro, Julia
    Keller, Thomas
    [J]. COMPOSITES PART B-ENGINEERING, 2010, 41 (02) : 148 - 156
  • [10] A multi-phase-field framework for non-uniform corrosion and corrosion-induced concrete cracking
    Fang, Xurui
    Pan, Zichao
    Ma, Rujin
    Chen, Airong
    [J]. COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2023, 414