Influence of print orientation and wet-dry storage time on the intaglio accuracy of additively manufactured occlusal devices

被引:21
作者
Revilla-Leon, Marta [1 ,2 ,3 ]
Cascos-Sanchez, Rocio [4 ]
Zeitler, Jonathan M. [5 ]
Barmak, Abdul B. [6 ]
Kois, John C. [1 ,7 ]
Gomez-Polo, Miguel [8 ,9 ]
机构
[1] Univ Washington, Sch Dent, Dept Restorat Dent, Grad Prosthodont, Seattle, WA USA
[2] Kois Ctr, Res & Digital Dent, Seattle, WA USA
[3] Tufts Univ, Sch Dent Med, Dept Prosthodont, Grad Prosthodont, Boston, MA USA
[4] Univ Complutense Madrid, Sch Dent, Dept Conservat Dent & Prosthodont, Postgrad Adv Implant Prosthodont, Madrid, Spain
[5] Kois Ctr, IT, Seattle, WA USA
[6] Univ Rochester, Eastman Inst Oral Hlth, Clin Res & Biostat, Med Ctr, Rochester, NY USA
[7] Kois Ctr, Seattle, WA USA
[8] Univ Complutense Madrid, Sch Dent, Dept Conservat Dent & Prosthodont, Madrid, Spain
[9] Univ Complutense Madrid, Sch Dent, Postgrad Program Adv Implant Prosthodont, Madrid, Spain
关键词
MECHANICAL-PROPERTIES; LAYER HEIGHT; RESISTANCE;
D O I
10.1016/j.prosdent.2022.12.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Different factors can affect the manufacturing accuracy of additively manufactured dental devices; however, the in fluence of print orientation and wet-dry storage time on their intaglio accuracy remains uncertain. Purpose. The purpose of this in vitro study was to assess the effect of print orientation (0, 45, 70, and 90 degrees) and wet-dry storage time (0, 30, 60, and 90 days) on the intaglio accuracy of additively manufactured occlusal devices. Material and methods. An occlusal device design was obtained in a standard tessellation language (STL) file format (control file) which was used to fabricate all the specimens by using a stereolithography printer (Form 3+) and a biocompatible resin material (Dental LTClear Resin, V2). Four groups were created based on the print orientation used to manufacture the specimens: 0, 45, 70, and 90 degrees. Each group was divided into 4 subgroups depending on the time elapsed between manufacturing and accuracy evaluation: 0, 30, 60, and 90 days. For the subgroup 0, a desktop scanner (T710) was used to digitize all the specimens. The 30-day subgroup specimens were stored for 30 days with the following daily storage protocol: 16 hours inside a dry lightproof container, followed by 8 hours in artificial saliva (1700-0305 Artificial Saliva) inside the same lightproof container. The specimens were then digitized by following the same procedures used for subgroup 0. For the subgroups 60 and 90, the identical procedures described for subgroup 30 were completed but after 60 and 90 days of storage, respectively. The reference STL file was used to measure the intaglio discrepancy with the experimental scans obtained among the different subgroups by using the root mean square error calculation. Two-way ANOVA and post hoc Tukey pairwise comparison tests were used to analyze the data ( a =.05). Results. Print orientation ( P<.001) and usage time ( P<.001) were significant predictors of the trueness value obtained. Additionally, the 0degree print orientation at day 0 group demonstrated the best trueness value among all the groups tested ( P<.05). No significant trueness discrepancies were found among the 45-, 70-, and 90-degree print orientation, or among the 30, 60, and 90 days of storage. A significant precision difference was found in the variance between print orientation groups across usage time subgroups. Conclusions. The print orientation and wet-dry storage times tested influenced the trueness and precision of the intaglio surfaces of the occlusal devices manufactured with the 3D printer and material selected.
引用
收藏
页码:1226 / 1234
页数:9
相关论文
共 46 条
[1]   Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations [J].
Alharbi, Nawal ;
Osman, Reham ;
Wismeijer, Daniel .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06) :760-767
[2]   Effect of different storage conditions on the fit of 3D-printed occlusal devices used to treat temporomandibular disorders [J].
Antonopoulou, Stavroula ;
Cho, Seok-Hwan ;
Kesterke, Matthew ;
Kontogiorgos, Elias ;
Korentzelos, Dimitrios .
JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03) :488.e1-488.e9
[3]   RESEARCH AND EDUCATION Effect of different fabrication methods of occlusal devices on periradicular stress distribution: A photoelastic analysis [J].
Arcas, Luciana Paula Benicio ;
Baroudi, Kusai ;
Silva-Concilio, Lais Regiane ;
Claro, Cristiane Aparecida de Assis ;
Amaral, Marina .
JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (04) :651-656
[4]   Surface Quality of 3D-Printed Models as a Function of Various Printing Parameters [J].
Arnold, Christin ;
Monsees, Delf ;
Hey, Jeremias ;
Schweyen, Ramona .
MATERIALS, 2019, 12 (12)
[5]   Comparing the mechanical properties of pressed, milled, and 3D-printed resins for occlusal devices [J].
Berli, Constantin ;
Thieringer, Florian M. ;
Sharma, Neha ;
Muller, Johannes A. ;
Dedem, Philipp ;
Fischer, Jens ;
Rohr, Nadja .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06) :780-786
[6]   Fibroblast behavior on conventionally processed, milled, and printed occlusal device materials with different surface treatments [J].
Bieger, Vivien ;
Thieringer, Florian M. ;
Fischer, Jens ;
Rohr, Nadja .
JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06) :939-945
[7]   Production tolerance of additive manufactured polymeric objects for clinical applications [J].
Braian, Michael ;
Jimbo, Ryo ;
Wennerberg, Ann .
DENTAL MATERIALS, 2016, 32 (07) :853-861
[8]   Trueness assessment of additively manufactured maxillary complete denture bases produced at different orientations [J].
Cameron, Andrew B. ;
Evans, Jane L. ;
Abuzar, Menaka A. ;
Tadakamadla, Santosh Kumar ;
Love, Robert M. .
JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01) :129-135
[9]   Effects of build orientation on adaptation of casting patterns for three-unit partial fixed dental prostheses fabricated by using digital light projection [J].
Chaiamornsup, Patcharanun ;
Iwasaki, Naohiko ;
Tsuchida, Yumi ;
Takahashi, Hidekazu .
JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05) :1047-1054
[10]   Accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates [J].
Chen, Li ;
Lin, Wei-Shao ;
Polido, Waldemar D. ;
Eckert, George J. ;
Morton, Dean .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (03) :309-314