A Wearable Internet of Things Device for Noninvasive Remote Monitoring of Vital Signs Related to Heart Failure

被引:1
作者
Iqbal, Sheikh Muhammad Asher [1 ,2 ]
Leavitt, Mary Ann [3 ]
Mahgoub, Imadeldin [1 ]
Asghar, Waseem [1 ,2 ,4 ]
机构
[1] Florida Atlantic Univ, Dept Elect Engn & Comp Sci, Boca Raton, FL 33431 USA
[2] Coll Engn & Comp Sci, Asghar Lab, Micro & Nanotechnol Med, Boca Raton, FL 33431 USA
[3] Florida Atlantic Univ, Christine E Lynn Coll Nursing, Boca Raton, FL 33431 USA
[4] Florida Atlantic Univ, Dept Biol Sci Courtesy Appointment, Boca Raton, FL 33431 USA
来源
IOT | 2024年 / 5卷 / 01期
关键词
cardiovascular disease; heart failure; wearable sensor; thoracic impedance; heart rate; activity status; Internet of Things; telemedicine;
D O I
10.3390/iot5010008
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
Cardiovascular disease is one of the leading causes of death in the world. Heart failure is a cardiovascular disease in which the heart is unable to pump sufficient blood to fulfill the body's requirements and can lead to fluid overload. Traditional solutions are not adequate to address the progression of heart failure. Herein, we report a body-mounted wearable sensor to monitor the parameters related to heart failure. These include heart rate, blood oxygen saturation, thoracic impedance, and activity status. The device is compact and wearable and measures the parameters continuously in real time. The device is an Internet of Things (IoT) device connected with a cloud-based database enabling the parameters to be visualized on a mobile application.
引用
收藏
页码:155 / 167
页数:13
相关论文
共 48 条
  • [11] Skin-Inspired Ultra-Tough Supramolecular Multifunctional Hydrogel Electronic Skin for Human-Machine Interaction
    Chen, Kun
    Liang, Kewei
    Liu, He
    Liu, Ruonan
    Liu, Yiying
    Zeng, Sijia
    Tian, Ye
    [J]. NANO-MICRO LETTERS, 2023, 15 (01)
  • [12] circuitbasics, Basics of the I2C Communication Protocol
  • [13] circuitbasics, Basics of the SPI Communication Protocol
  • [14] DAIC, ICD Manufacturers Must Increase Battery Life to Cut Costs, Improve Care
  • [15] Devices A., Accelerometer ADXL362
  • [16] Devices A MSPS, 12-Bit Impedance Converter, Network Analyzer AD5933
  • [17] Detecting Heart Failure Decompensation by Measuring Transthoracic Bioimpedance in the Outpatient Setting: Rationale and Design of the SENTINEL-HF Study
    Dovancescu, Silviu
    Saczynski, Jane S.
    Darling, Chad E.
    Riistama, Jarno
    Kuniyoshi, Fatima Sert
    Meyer, Theo
    Goldberg, Robert
    McManus, David D.
    [J]. JMIR RESEARCH PROTOCOLS, 2015, 4 (04):
  • [18] Firebase, ABOUT US
  • [19] Early Indication of Decompensated Heart Failure in Patients on Home-Telemonitoring: A Comparison of Prediction Algorithms Based on Daily Weight and Noninvasive Transthoracic Bio-impedance
    Gyllensten, Illapha Cuba
    Bonomi, Alberto G.
    Goode, Kevin M.
    Reiter, Harald
    Habetha, Joerg
    Amft, Oliver
    Cleland, John G. F.
    [J]. JMIR MEDICAL INFORMATICS, 2016, 4 (01)
  • [20] Hemotag, Rapid Vitals for Monitoring Structural Heart Health