Ex-situ Characterization of Nb-Ti Alloy/Pt Coated Stainless Steel Bipolar Plates for Proton Exchange Membrane Fuel Cells

被引:15
作者
Madhavan, Pramoth Varsan [1 ]
Shahgaldi, Samaneh [2 ]
Li, Xianguo [1 ]
机构
[1] Univ Waterloo, Mech & Mechatron Engn, Waterloo, ON, Canada
[2] Univ Quebec Trois Rivieres, Hydrogen Res Inst, Quebec City, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Fuel cell; Metallic bipolar plate; Nb-Ti alloy coating; Corrosion testing; Electrical and thermal conductivities; Interfacial contact resistance; THERMAL-CONDUCTIVITY; ELECTROCHEMICAL-BEHAVIOR; ELECTRICAL-CONDUCTIVITY; CORROSION-RESISTANCE; PROTECTIVE-COATINGS; CONTACT RESISTANCE; PEMFC; NIOBIUM; 304-STAINLESS-STEEL; HYDROGEN;
D O I
10.1016/j.enconman.2024.118536
中图分类号
O414.1 [热力学];
学科分类号
摘要
Metallic bipolar plates are crucial for the development of compact and lightweight proton exchange membrane fuel cell stacks; however, most of them encounter durability and conductivity challenges in the fuel cell environment. In this study, Nb-Ti alloy/Pt coatings are deposited on SS316L plates to enhance corrosion resistance, surface wettability, electrical and thermal conductivity, with reduced interfacial contact resistance. Corrosion resistance is assessed by exposing test samples to a 1M H2SO4 acidic environment at 25 degrees C and 80 degrees C, respectively, via potentiostatic and potentiodynamic polarization tests. It is found that Nb-Ti alloy/Pt coatings exhibit exceptional stability, with corrosion potential increased by 2.5 (at 25 degrees C) and 0.5 (at 80 degrees C) times and corrosion current density reduced by orders of magnitude; and their anti-corrosion performance far exceeds the technical targets set by the US Department of Energy, with a protective efficiency of 99.98 % at both temperatures tested. The coated samples have reduced water affinity, indicated by significantly larger contact angle values compared to the uncoated samples in both pre-and post-corrosion tests. The incorporation of Nb-Ti alloy/Pt coatings on SS316L increases the in-plane electrical conductivity by 42.6 % and thermal conductivity by 3.5 %; surpassing the US Department of Energy's technical targets in these categories as well. At a compaction force of 140 N/cm2, the interfacial contact resistance for the coated samples is about 2.5 times lower than the Department of Energy's requirements. These results indicate the viability of Nb-Ti alloy/Pt coated SS316L bipolar plates for fuel cell applications.
引用
收藏
页数:14
相关论文
共 50 条
[31]   A review of modified metal bipolar plates for proton exchange membrane fuel cells [J].
Wu, Sida ;
Yang, Weimin ;
Yan, Hua ;
Zuo, Xiahua ;
Cao, Zibo ;
Li, Haoyang ;
Shi, Meinong ;
Chen, Hongbo .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (12) :8672-8701
[32]   Carbon coated stainless steel bipolar plates in polymer electrolyte membrane fuel cells [J].
Feng, Kai ;
Cai, Xun ;
Sun, Hailin ;
Li, Zhuguo ;
Chu, Paul K. .
DIAMOND AND RELATED MATERIALS, 2010, 19 (11) :1354-1361
[33]   Long-Term Operation of Nb-Coated Stainless Steel Bipolar Plates for Proton Exchange Membrane Water Electrolyzers [J].
Stiber, Svenja ;
Hehemann, Michael ;
Carmo, Marcelo ;
Mueller, Martin ;
Ayers, Katherine E. ;
Capuano, Christopher ;
Danilovic, Nemanja ;
Morawietz, Tobias ;
Biswas, Indro ;
Gazdzicki, Pawel ;
Heger, Jan-Frederik ;
Gago, Aldo Saul ;
Friedrich, Kaspar Andreas .
ADVANCED ENERGY AND SUSTAINABILITY RESEARCH, 2022, 3 (08)
[34]   Direct observation of the passive layer on high nitrogen stainless steel used as bipolar plates for proton exchange membrane fuel cells [J].
Kumagai, Masanobu ;
Myung, Seung-Taek ;
Yashiro, Hitoshi ;
Katada, Yasuyuki .
JOURNAL OF POWER SOURCES, 2012, 210 :92-95
[35]   Optimisation of pack chromised stainless steel for proton exchange membrane fuel cells bipolar plates using response surface methodology [J].
Oladoye, A. M. ;
Carton, J. G. ;
Benyounis, K. ;
Stokes, J. ;
Olabi, A. G. .
SURFACE & COATINGS TECHNOLOGY, 2016, 304 :384-392
[36]   Influence of pH on the passivation behaviour of 904L stainless steel bipolar plates for proton exchange membrane fuel cells [J].
Luo, Hong ;
Su, Huaizhi ;
Dong, Chaofang ;
Xiao, Kui ;
Li, Xiaogang .
JOURNAL OF ALLOYS AND COMPOUNDS, 2016, 686 :216-226
[37]   Stability of type 310S stainless steel bipolar plates tested at various current densities in proton exchange membrane fuel cells [J].
Kumagai, Masanobu ;
Myung, Seung-Taek ;
Katada, Yasuyuki ;
Yashiro, Hitoshi .
ELECTROCHIMICA ACTA, 2016, 211 :754-760
[38]   Interface-induced degradation of amorphous carbon films/stainless steel bipolar plates in proton exchange membrane fuel cells [J].
Li, Hao ;
Guo, Peng ;
Zhang, Dong ;
Liu, Linlin ;
Wang, Zhenyu ;
Ma, Guanshui ;
Xin, Yang ;
Ke, Peiling ;
Saito, Hidetoshi ;
Wang, Aiying .
JOURNAL OF POWER SOURCES, 2020, 469 (469)
[39]   A Review of Metallic Bipolar Plates for Proton Exchange Membrane Fuel Cells: Materials and Fabrication Methods [J].
Karimi, Shahram ;
Fraser, Norman ;
Roberts, Bronwyn ;
Foulkes, Frank R. .
ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2012, 2012
[40]   Preparation and properties of conductive Ti4O7 surface coating for Ti bipolar plates of proton exchange membrane fuel cells [J].
Tan, Qianyun ;
Wang, Yanli .
JOURNAL OF ALLOYS AND COMPOUNDS, 2022, 911