A novel naphthalimide-derived " turn-off " chemosensor for the detection of Cu2+, F- and CN- ions

被引:3
|
作者
Kaur, Gurdeep [1 ]
Kumar, Gulshan [2 ]
Singh, Iqubal [3 ]
机构
[1] Lovely Profess Univ, Sch Chem Engn & Phys Sci, Dept Chem, Phagwara 144411, India
[2] Banasthali Univ, Dept Chem, Banasthali Newai 304022, Rajasthan, India
[3] Lovely Profess Univ, Sch Pharmaceut Sci, Phagwara 144411, India
关键词
Napthalimide; Absorbance; Chemosensor; Limit of detection; TD; DFT; FLUORESCENT; HYDRAZONES; SENSORS; DESIGN; COPPER;
D O I
10.1016/j.molstruc.2024.139252
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The development of selective chemosensor for the detection of detrimental analytes in the environment is crucial due to their catastrophic effects. In this study, a novel Schiff base derived from naphthalimide and salicylaldehyde was designed and prepared for the detection of Cu2+, 2 + , F-,- , and CN-ions- ions in CH3CN 3 CN as medium. The chemosensor exhibits a red shift in the presence of Cu2+, 2 + , F-,- , and CN-- ions accompanied by naked eye color change in the presence of F-- and CN-- ions. On the other hand, a "turn-off" response was observed in the presence of ion Cu2+, 2 + , F-,- , and CN-- ions in the fluorescent spectrum. The good anti-interference characteristics, strong binding, and low limit of detection (LOD) of the chemosensor revealed its sensitivity against Cu2+, 2 + , F-,- , and CN-- ions i.e. 1.25 x 10-5-5 M, 1.07 x 10-6-6 M, and 0.98 x 10-6-6 M, respectively. The binding ratio (1:1) was determined by Job's plot between the chemosensor and ions. In addition, the binding of ions with the chemosensor was proposed which was further supported by time-dependent density functional theory (TD-DFT) and IR spectrum data.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Pyridoxal Derived AIEgen for Fluorescence Turn-off Sensing of Cu2+ and Fe2+ Ions and Fluorescence Imaging of Latent Fingerprints
    Mahesh Umare
    Dhvani A. Patel
    Vinita Bhardwaj
    Ashok Kumar SK
    Suban K. Sahoo
    Journal of Fluorescence, 2023, 33 : 601 - 611
  • [42] Pyridoxal Derived AIEgen for Fluorescence Turn-off Sensing of Cu2+ and Fe2+ Ions and Fluorescence Imaging of Latent Fingerprints
    Umare, Mahesh
    Patel, Dhvani A.
    Bhardwaj, Vinita
    Sk, Ashok Kumar
    Sahoo, Suban K.
    JOURNAL OF FLUORESCENCE, 2023, 33 (02) : 601 - 611
  • [43] A dual-mode chemosensor: Highly selective colorimetric fluorescent probe for Cu2+ and F- ions
    Udhayakumari, Duraisamy
    Velmathi, Sivan
    Chen, Wei-Chieh
    Wu, Shu-Pao
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 375 - 381
  • [44] "Test kit" of chromogenic and ratiometric 1,10-phenanthroline based chemosensor for the recognition of F- and CN- ions
    Alreja, Priya
    Kaur, Navneet
    INORGANIC CHEMISTRY COMMUNICATIONS, 2019, 110
  • [45] A novel naphthalimide-appended salamo-type fluorescent sensor for continuous "on-off-on" detection of Cu2+and CN- ions, sensing mechanisms and applications
    Liu, Guo-Hua
    Chen, Rui
    Yang, Ru-Wa
    Li, Xiao-Xia
    Dong, Wen-Kui
    JOURNAL OF MOLECULAR STRUCTURE, 2024, 1309
  • [46] CS-symmetric triarylborane substituted bisthiazole for selective detection of F- and CN- ions
    Maragani, Ramesh
    Reddy, T. Sheshashena
    Misra, Rajneesh
    TETRAHEDRON LETTERS, 2016, 57 (34) : 3853 - 3857
  • [47] A highly selective and reversible turn-off fluorescent chemosensor for Cu2+ based on electrospun nanofibrous membrane modified with pyrenecarboxaldehyde
    Cui, Xiangxu
    Li, Tingting
    Li, Jiashuang
    An, Yukun
    An, Libao
    Zhang, Xinmu
    Zhang, Zhiming
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 207 : 173 - 182
  • [48] Highly selective turn-off fluorogenic chemosensor for the detection of toxic metal Cu2+ ion in environment: A DFT, MTT assay and docking studies
    Steffy, A.
    Sujatha, R.
    Shakina, J.
    Tharmaraj, P.
    Jenila, R. Mary
    Potheher, I. Vetha
    JOURNAL OF MOLECULAR STRUCTURE, 2025, 1333
  • [49] Highly sensitive and selective "turn-off" fluorescent probes based on coumarin for detection of Cu2+
    Wu, Weichun
    Min, Shenxi
    Tong, Qin
    Wang, Junhao
    Hu, Jianghong
    Dhamsaniya, Ashish
    Shah, Anamik K.
    Mehta, Vaibhav P.
    Dong, Bin
    Song, Bo
    COLLOID AND INTERFACE SCIENCE COMMUNICATIONS, 2021, 43
  • [50] Pyrene-Based "Turn-Off" Probe with Broad Detection Range for Cu2+, Pb2+ and Hg2+ Ions
    Merz, Viktor
    Merz, Julia
    Kirchner, Maximilian
    Lenhart, Julian
    Marder, Todd B.
    Krueger, Anke
    CHEMISTRY-A EUROPEAN JOURNAL, 2021, 27 (31) : 8118 - 8126