A Comparative Study of LC-MS and FIA-(ESI)MS for Quantitation of S-Allyl-L-Cysteine in Aged Garlic Supplements

被引:0
|
作者
Jimenez-Amezcua, Ignacio [1 ,2 ]
Diez-Municio, Marina [2 ]
Ruiz-Matute, Ana Isabel [1 ]
Soria, Ana Cristina [1 ]
机构
[1] Inst Quim Organ Gen IQOG CSIC, Juan Cierva 3, Madrid 28006, Spain
[2] Pharmact Biotech Prod SLU, Faraday 7, Madrid 28049, Spain
关键词
food supplements; aged garlic; S-allyl-L-cysteine (SAC); LC-MS; FIA-(ESI)MS; frauds; quality; genuineness; MASS-SPECTROMETRY; COMPOSITIONAL CHANGES; DIETARY-SUPPLEMENTS; ADULTERATION; EXTRACT;
D O I
10.3390/foods13172645
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The increasing consumption of food supplements demands the development of improved analytical methodologies to ensure their quality and authenticity. In this paper, two new approaches, liquid chromatography coupled to mass spectrometry (LC-MS) and flow injection analysis-(electrospray ionization) mass spectrometry (FIA-(ESI)MS), were optimized and validated for their application in the quantitative analysis of bioactive S-allyl-L-cysteine (SAC) in commercial aged garlic supplements (AGS). Although both methodologies were found to be useful for the sensitive and precise quantitation of SAC, the LC-MS approach allowed the differential determination of SAC and its bioactive diastereoisomer, S-1-propenyl-L-cysteine (S1PC), together with the identification of a number of organosulfur compounds typical of garlic. Mass fingerprints by FIA-(ESI)MS were proposed as an advantageous alternative to LC-MS analysis when the fast (4 min/sample) screening of AGS for their SAC content is intended, as in applications aimed at high-throughput quality control or standardization. Finally, the results gathered by the application of these two methodologies evidenced the highly variable composition of commercial AGS, as well as the identification of a number of potential composition frauds affecting their genuineness and benefits on health.
引用
收藏
页数:13
相关论文
共 4 条
  • [1] Highly sensitive LC-MS/MS-ESI method for simultaneous quantitation of albendazole and ricobendazole in rat plasma and its application to a rat pharmacokinetic study
    Sharma, Kuldeep
    Kandaswamy, Murugesh
    Mithra, Chandan
    Meena, Ashok Kumar
    Giri, Sanjeev
    Rajagopal, Sriram
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (02) : 247 - 255
  • [2] An LC-MS/MS Method to Measure S-Methyl-l-Cysteine and S-Methyl-l-Cysteine Sulfoxide in Human Specimens Using Isotope Labelled Internal Standards
    Sivapalan, Tharsini
    Melchini, Antonietta
    Coode-Bate, Jack
    Needs, Paul W.
    Mithen, Richard F.
    Saha, Shikha
    MOLECULES, 2019, 24 (13):
  • [3] Determination of 20(S)-protopanaxadiol in rat plasma by LC-MS/MS and its application to the pharmacokinetic study: A comparative study of its solution and two oral formulations
    Han, Meihua
    Chen, Jing
    Wang, Yuqin
    Chen, Shilin
    Wang, Xiangtao
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (08) : 730 - 735
  • [4] Validated LC-MS method for simultaneous quantitation of catalpol and harpagide in rat plasma: application to a comparative pharmacokinetic study in normal and diabetic rats after oral administration of Zeng-Ye-Decoction
    Feng, Yukun
    Liu, Zhenzhen
    Peng, Ying
    Zhang, Lunhui
    Ju, Ping
    Bi, Kaishun
    Chen, Xiaohui
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (11) : 1503 - 1510