摘要
Uric acid (UA) is the end product of purine metabolism, which is involved in many physiological processes in humans. This compound is produced daily in the human body and the excess is excreted in urine. For various reasons, uric acid in human serum that is lower or higher than the reference range causes some diseases such as liver diseases, nephritis, multiple sclerosis and diabetes. Hence, determination of UA at trace levels is very crucial. Here, a pencil graphite electrode (PGE) modified with graphene oxide-zinc oxide (GO-ZnO) nanocomposite was used to develop an electrochemical biosensor (GO-ZnO/PGE) for UA detection. The prepared GOZnO modified electrodes was characterized by scanning electron microscopy (SEM), Energy-Dispersive X-Ray Spectroscopy (EDX), Electrochemical Impedance Spectroscopy (EIS) and Cyclic Voltammetry (CV). It was revealed that the existence of ZnO in the GO-ZnO/PGE largely enhanced the surface area and increased its sensitivity for electrochemical sensing of analyte. The uric acid biosensor exhibited voltammetric peaks in the differential pulse voltammetry (DPV) measurements, allowing electrochemical detection of UA. The detection limit of UA was found to be 2.56 mu M in buffer medium in the range of 10-100 mu M UA. The detection limit of UA was found to be 4.76 mu M in 1:1000 diluted FBS medium in the range of 10-100 mu M of UA. The GO-ZnO/PGE provided the results in good reproducubility based on electrochemical measuruments while detecting UA. Furthermore, selectivity tests were also performed in FBS medium containing possible interferents such as ascorbic acid (AA) and Glucose (Glu), demonstrating the applicability of GO-ZnO modified electrodes. Sensitivity was calculated for phosphate-buffered saline (PBS) and fetal bovine serum (FBS) mediums and found to be 0.22 and 0.47 mu A mu g-1 mL cm-2, respectively, which validates the good sensitivity of the GO-ZnO/PGE electrodes.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Electrochemical detection of microRNAs by graphene oxide modified disposable graphite electrodes
    Eksin, Ece
    Erdem, Arzum
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 810 : 232 - 238
  • [2] A Porphyrin-functionalized Graphene Oxide Nanocomposite for Simultaneous Detection of Dopamine and Uric Acid
    Wei, Chuangyu
    Tu, Jingfang
    Liu, Hanqi
    Mei, Zhuang
    Gao, Xinyu
    Yu, Jinshi
    Cai, Xue
    Li, Xiyou
    Chen, Yanli
    CHEMNANOMAT, 2022, 8 (10)
  • [3] The Electroxidation of Uric Acid at Zinc Oxide/Reduced Graphene Oxide Composites Modified Electrode
    Yusoff, Farhanini
    Sang, Lee Pak
    Saleh, Noorashikin Md
    3RD INTERNATIONAL SCIENCES, TECHNOLOGY & ENGINEERING CONFERENCE (ISTEC) 2018 - MATERIAL CHEMISTRY, 2018, 2031
  • [4] Sensitive detection of uric acid on partially electro-reduced graphene oxide modified electrodes
    Zhang, Ziping
    Yin, Jungang
    ELECTROCHIMICA ACTA, 2014, 119 : 32 - 37
  • [5] Adsorption and Kinetics Studies of Cr (VI) by Graphene Oxide and Reduced Graphene Oxide-Zinc Oxide Nanocomposite
    Naseem, Taiba
    Bibi, Fozia
    Arif, Saira
    Waseem, Muhammad
    Haq, Sirajul
    Azra, Mohamad Nor
    Liblik, Taavi
    Zekker, Ivar
    MOLECULES, 2022, 27 (21):
  • [6] Preparation of Polydiallyl Dimethyl Ammonium Chloride Modified Reduced Graphene Oxide/Zinc Oxide Composite Materials and Its Application in Detection of Uric Acid
    Fan Yong-Mei
    Zhang Ji-Mei
    Mi Chao
    Cai Yu-Ling
    Zhang Li-Ping
    Zhu Hai-Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (01) : 33 - 38
  • [8] Synthesis, characterization and enhanced antimicrobial activity of reduced graphene oxide-zinc oxide nanocomposite
    Rajaura, Rajveer Singh
    Sharma, Vinay
    Ronin, Rishabh Shrivastava
    Gupta, Deepak K.
    Srivastava, Subodh
    Agrawal, Kailash
    Vijay, Y. K.
    MATERIALS RESEARCH EXPRESS, 2017, 4 (02)
  • [9] Copper oxide nanoparticles modified electrodes for high-sensitivity detection of uric acid in athletes
    Feng, Shisong
    Xing, Xuanshuo
    Hou, Wenzhi
    ALEXANDRIA ENGINEERING JOURNAL, 2024, 101 : 1 - 7
  • [10] ZnS and Reduced Graphene Oxide Nanocomposite-Based Non-Enzymatic Biosensor for the Photoelectrochemical Detection of Uric Acid
    Zhao, Yao
    Peng, Niancai
    Gao, Weizhuo
    Hu, Fei
    Zhang, Chuanyu
    Wei, Xueyong
    BIOSENSORS-BASEL, 2024, 14 (10):