Hybrid indirect and regenerative evaporative cooling design for enhanced cooling density

被引:1
|
作者
Srivastava, Rishabh [1 ]
Turpati, Sunilkumar [1 ]
Kochunni, Sarun Kumar [1 ]
Swaminathan, Jaichander [2 ]
机构
[1] Indian Inst Technol, Mech Engn Discipline, Gandhinagar 382355, Gujarat, India
[2] Indian Inst Sci, Interdisciplinary Ctr Energy Res, Bangalore 560012, Karnataka, India
关键词
Maisotsenko cycle; Dew point cooler; Indirect evaporative cooler; Air conditioning; Hybridization; optimal design; MAISOTSENKO-CYCLE; FLOW; COOLER; HEAT; SYSTEM;
D O I
10.1016/j.enconman.2024.118674
中图分类号
O414.1 [热力学];
学科分类号
摘要
Indirect evaporative coolers (IEC) enable low-energy cooling of air without humidification. While a conventional IEC is limited to cooling incoming air down to its wet-bulb temperature, a regenerative IEC (M-cycle) can cool air further, approaching its dew point. In this study, a hybrid IEC-M-cycle design is proposed and evaluated for enhanced cooling, with initial cooling in the IEC portion, followed by subsequent cooling in the M-cycle section. Such a hybrid design produces the same product air temperature as a stand-alone M-cycle with 12-18 % lower heat transfer area. At a fixed system size, around 20 % higher cooling rate is achieved with the hybrid system while achieving the same product air temperature by optimizing the area fraction of the IEC section, and the recirculation flow rate. Overall, the proposed hybrid design enables improved indirect evaporative cooling at lower system sizes.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] A review of recent advances in indirect evaporative cooling technology
    Sajjad, Uzair
    Abbas, Naseem
    Hamid, Khalid
    Abbas, Saleem
    Hussain, Imtiyaz
    Ammar, Syed Muhammad
    Sultan, Muhammad
    Ali, Hafiz Muhammad
    Hussain, Muzamil
    Tauseef-ur-Rehman
    Wang, Chi Chuan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 122
  • [32] Indirect evaporative cooling: Past, present and future potentials
    Duan, Zhiyin
    Zhan, Changhong
    Zhang, Xingxing
    Mustafa, Mahmud
    Zhao, Xudong
    Alimohammadisagvand, Behrang
    Hasan, Ala
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (09): : 6823 - 6850
  • [33] Surface wettability effect on an indirect evaporative cooling system
    Wang, TA
    Reid, RL
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 1, 1996, 102 : 427 - 433
  • [34] A review of indirect evaporative cooling operating conditions and performances
    Porumb, Bogdan
    Unguresan, Paula
    Tutunaru, Lucian Fechete
    Serban, Alexandru
    Balan, Mugur
    EENVIRO-YRC 2015 - BUCHAREST, 2016, 85 : 452 - 460
  • [35] Indirect evaporative cooling for buildings: A comprehensive patents review
    Mohammed, Ramy H.
    El-Morsi, Mohamed
    Abdelaziz, Omar
    JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [36] Surface wettability effect on an indirect evaporative cooling system
    Wang, Tiebin A.
    Reid, Robert L.
    ASHRAE Transactions, 1996, 102 (01): : 427 - 433
  • [37] Indirect Evaporative Cooling Drives Data Center Efficiency
    Finch, Paul
    ASHRAE JOURNAL, 2020, 62 (06) : 40 - 47
  • [38] Sustainable cooling system for Kuwait hot climate combining diurnal radiative cooling and indirect evaporative cooling system
    Katramiz, Elvire
    Al Jebaei, Hussein
    Alotaibi, Sorour
    Chakroun, Walid
    Ghaddar, Nesreen
    Ghali, Kamel
    ENERGY, 2020, 213
  • [40] Evaporative cooling enhanced by fibrovascular capillary structures
    Kang, Zhanxiao
    Shahzad, Amir
    Fan, Jintu
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 202