Prompt gamma timing for proton range verification with TlBr and TlCl as pure Cherenkov emitters

被引:3
|
作者
Ellin, Justin [1 ]
Rebolo, Leonor [1 ]
Backfish, Michael [2 ]
Prebys, Eric [2 ,3 ]
Arino-Estrada, Gerard [1 ,4 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Univ Calif Davis, Crocker Nucl Lab, Davis, CA USA
[3] Univ Calif Davis, Dept Phys, Davis, CA USA
[4] Barcelona Inst Sci & Technol, Inst Fis Altes Energies, Barcelona, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 11期
关键词
prompt gamma timing; TlBr; TlCl; Proton therapy range verification;
D O I
10.1088/1361-6560/ad4304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Prompt gamma timing (PGT) uses the detection time of prompt gammas emitted along the range of protons in proton radiotherapy to verify the position of the Bragg peak (BP). Cherenkov detectors offer the possibility of enhanced signal-to-noise ratio (SNR) due to the inherent physics of Cherenkov emission which enhances detection of high energy prompt gamma rays relative to other induced uncorrelated signals. In this work, the PGT technique was applied to 3 semiconductor material slabs that emit only Cherenkov light for use in a full scale system: a 3 x 3 x 20 mm3 TlBr, a 12 x 12 x 12 mm3 TlBr, and a 5 x 5 x 5 mm3 TlCl. Approach. A polymethyl methacrylate (PMMA) target was exposed to a 67.5 MeV, 0.5 nA proton beam and shifted in 3 mm increments at the Crocker nuclear laboratory (CNL) in Davis, CA, USA. A fast plastic scintillator coupled to a photomultiplier tube (PMT) provided the start reference for the proton time of flight. Time of flight (TOF) distributions were generated using this reference and the gamma-ray timestamp in the Cherenkov detector. Main results. The SNR of the proton correlated peaks relative to the background was 20, 29, and 30 for each of the three samples, respectively. The upper limit of the position resolutions with the TlCl sample were 2 mm, 3 mm, and 5 mm for 30k, 10k, and 5k detected events, respectively. The time distribution of events with respect to the reference reproduced with clarity the periodicity of the beam, implying a very high SNR of the Cherenkov crystals to detect prompt gammas. Background presence from the neutron-induced continuum, prompt gammas from deuterium, or positron activation were not observed. Material choice and crystal dimensions did not seem to affect significantly the outcome of the results. Significance. These results show the high SNR of the pure Cherenkov emitters TlBr and TlCl for the detection of prompt gammas in a proton beam with current of clinical significance and their potential for verifying the proton range. The accuracy in determining shifts of the BP was highly dependent on the number of events acquired, therefore, the performance of these detectors are expected to vary with different beam conditions such as current, pulse repetition, and proton bunch width.
引用
收藏
页数:9
相关论文
共 5 条
  • [1] Particle range retrieval in heterogeneous phantoms with the prompt gamma ray timing method at a clinical proton accelerator
    Hueso-Gonzalez, F.
    Golnik, C.
    Berthel, M.
    Dreyer, A.
    Enghardt, W.
    Fiedler, F.
    Heidel, K.
    Janssens, G.
    Kormoll, T.
    Petzoldt, J.
    Prieels, D.
    Priegnitz, M.
    Roemer, K. E.
    Smeets, J.
    Sobiella, M.
    Vander Stappen, F.
    Wagner, A.
    Weinberger, D.
    Pausch, G.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] Stopping power and range estimations in proton therapy based on prompt gamma timing: motion models and automated parameter optimization
    Werner, Julius
    Pennazio, Francesco
    Schmid, Niklas
    Fiorina, Elisa
    Bersani, Davide
    Cerello, Piergiorgio
    Kasprzak, Jona
    Mosco, Nicola
    Ranjbar, Sahar
    Sacchi, Roberto
    Ferrero, Veronica
    Rafecas, Magdalena
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (14):
  • [3] First Cerenkov charge-induction (CCI) TlBr detector forTOF-PET and proton range verification
    Arino-Estrada, Gerard
    Mitchell, Gregory S.
    Kim, Hadong
    Du, Junwei
    Kwon, Sun Il
    Cirignano, Leonard J.
    Shah, Kanai S.
    Cherry, Simon R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (17):
  • [4] Proton therapy monitoring: spatiotemporal emission reconstruction with prompt gamma timing and implementation with PET detectors
    Pennazio, Francesco
    Ferrero, Veronica
    D'Onghia, Grazia
    Garbolino, Sara
    Fiorina, Elisa
    Villarreal, Oscar Ariel Marti
    Milian, Felix Mas
    Monaco, Vincenzo
    Monti, Valeria
    Patera, Alessandra
    Werner, Julius
    Wheadon, Richard
    Rafecas, Magdalena
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (06):
  • [5] Ultra-fast prompt gamma detection in single proton counting regime for range monitoring in particle therapy
    Marcatili, S.
    Collot, J.
    Curtoni, S.
    Dauvergne, D.
    Hostachy, J-Y
    Koumeir, C.
    Letang, J. M.
    Livingstone, J.
    Metivier, V
    Gallin-Martel, L.
    Gallin-Martel, M. L.
    Muraz, J. F.
    Servagent, N.
    Testa, E.
    Yamouni, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):