Membrane role in heat and mass transfer resistance distribution and performance of hollow fiber membrane contactor for SGMD desalination

被引:2
|
作者
Li, Guopei [1 ,2 ]
Wang, Junru [1 ]
Zhang, Leigang [1 ,2 ]
Li, Heyong [1 ]
机构
[1] Zhengzhou Univ Light Ind, Coll Energy & Power Engn, Zhengzhou, Peoples R China
[2] Henan Int Joint Lab Energy Efficient Convers & Uti, Zhengzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Hollow fiber membrane; Heat mass transfer resistance distribution; Porous membrane microstructure; Sweeping gas membrane distillation; Desalination; THERMAL EFFICIENCY; SEAWATER DESALINATION; REVERSE-OSMOSIS; DISTILLATION; FLOW; BUNDLE; WATER; OPTIMIZATION; SYSTEM; MODEL;
D O I
10.1016/j.ijthermalsci.2024.109133
中图分类号
O414.1 [热力学];
学科分类号
摘要
Hollow fiber membrane contactor (HFMC) is the core device of heat mass exchange between seawater solution and sweeping air in sweeping gas membrane distillation (SGMD) desalination. In order to reveal the distribution of heat and mass transfer resistance on feed solution side, porous membrane side and sweeping air side, a mathematical model considering the simultaneous heat mass transfer and water vapor diffusion mechanism in the membrane pores was established for the cross-flow HFMC. The simulation results of the model were compared with experimental results and literature results. Comparison shows that the deviation of simulation results of the model is less than 13.4 %, which verifies the accuracy and reliability of the simulation results. Influences of the main structural characteristics of porous membrane on the resistance distribution of heat and mass transfer, efficiency and membrane flux were explored. Air side dominates the heat transfer process, while the membrane side accounts for less than 39 % of the total heat transfer resistance for the main range of membrane microstructure parameters investigated. The mass transfer is controlled by the porous membrane except for thin membrane with a thickness of less than 100 mu m. Membranes with porosity above 0.8 and as thin as possible can achieve better mass transfer efficiency and freshwater flux. Increasing mean pore diameter has a strong promotion effect on the increase of membrane flux before it reaches 150 nm, and beyond this critical value, the water vapor diffusion mechanism changes from Knudsen collision to molecular collision. Effects of different operating parameters and membrane microstructure parameters on air temperature distribution and humidity distribution were also analyzed.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Heat and mass transfer enhancement in a cross-flow elliptical hollow fiber membrane contactor used for liquid desiccant air dehumidification
    Huang, Si-Min
    Yang, Minlin
    JOURNAL OF MEMBRANE SCIENCE, 2014, 449 : 184 - 192
  • [32] Heat and mass transfer in membrane distillation used for desalination with slip flow
    Orfi, Jamel
    Loussif, Nizar
    Davies, Philip A.
    DESALINATION, 2016, 381 : 135 - 142
  • [33] Heat transfer study of PVDF hollow fiber heat exchanger for desalination process
    Song, Shasha
    Shan, Huiting
    Liu, Jun
    Li, Baoan
    DESALINATION, 2018, 446 : 1 - 11
  • [34] Sweeping air membrane distillation: Conjugate heat and mass transfer in a hollow fiber membrane tube bank with an in-line arrangement
    Huang, Si-Min
    Yang, Minlin
    Tu, Junling
    Shao, Youyuan
    Zuo, Yuanzhi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 108 : 2191 - 2197
  • [35] Shell-Side Mass-Transfer Performance in Hollow-Fiber Membrane Contactors
    Shen, Shufeng
    Kentish, Sandra E.
    Stevens, Geoff W.
    SOLVENT EXTRACTION AND ION EXCHANGE, 2010, 28 (06) : 817 - 844
  • [36] Mass transfer enhancement of hollow fiber membrane deoxygenation by Dean vortices
    Kong, Qing-ran
    Zhang, Yi-zhen
    Tian, Hua
    Fang, Li-feng
    Zhou, Ming-yong
    Zhu, Li-ping
    Zhu, Bao-ku
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2019, 20 (08): : 601 - 613
  • [37] Computation of Global and Local Mass Transfer in Hollow Fiber Membrane Modules
    Lukitsch, Benjamin
    Ecker, Paul
    Elenkov, Martin
    Janeczek, Christoph
    Haddadi, Bahram
    Jordan, Christian
    Krenn, Claus
    Ullrich, Roman
    Gfoehler, Margit
    Harasek, Michael
    SUSTAINABILITY, 2020, 12 (06)
  • [38] An Analytical Solution to Heat and Mass Transfer in Hollow Fiber Membrane Contactors for Liquid Desiccant Air Dehumidification
    Zhang, Li-Zhi
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (09):
  • [39] HEAT AND MASS TRANSFER CHARACTERISTICS OF HOLLOW FIBER MEMBRANE BASED GENERATOR IN VAPOR ABSORPTION REFRIGERATION SYSTEM
    Hong, Sung Joo
    Hihara, Eiji
    Dang, Chaobin
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 1292 - 1299
  • [40] HEAT AND MASS TRANSFER CHARACTERISTICS OF HOLLOW FIBER MEMBRANE BASED GENERATOR IN VAPOR ABSORPTION REFRIGERATION SYSTEM
    Hong, Sung Joo
    Hihara, Eiji
    Dang, Chaobin