Membrane role in heat and mass transfer resistance distribution and performance of hollow fiber membrane contactor for SGMD desalination

被引:1
|
作者
Li, Guopei [1 ,2 ]
Wang, Junru [1 ]
Zhang, Leigang [1 ,2 ]
Li, Heyong [1 ]
机构
[1] Zhengzhou Univ Light Ind, Coll Energy & Power Engn, Zhengzhou, Peoples R China
[2] Henan Int Joint Lab Energy Efficient Convers & Uti, Zhengzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Hollow fiber membrane; Heat mass transfer resistance distribution; Porous membrane microstructure; Sweeping gas membrane distillation; Desalination; THERMAL EFFICIENCY; SEAWATER DESALINATION; REVERSE-OSMOSIS; DISTILLATION; FLOW; BUNDLE; WATER; OPTIMIZATION; SYSTEM; MODEL;
D O I
10.1016/j.ijthermalsci.2024.109133
中图分类号
O414.1 [热力学];
学科分类号
摘要
Hollow fiber membrane contactor (HFMC) is the core device of heat mass exchange between seawater solution and sweeping air in sweeping gas membrane distillation (SGMD) desalination. In order to reveal the distribution of heat and mass transfer resistance on feed solution side, porous membrane side and sweeping air side, a mathematical model considering the simultaneous heat mass transfer and water vapor diffusion mechanism in the membrane pores was established for the cross-flow HFMC. The simulation results of the model were compared with experimental results and literature results. Comparison shows that the deviation of simulation results of the model is less than 13.4 %, which verifies the accuracy and reliability of the simulation results. Influences of the main structural characteristics of porous membrane on the resistance distribution of heat and mass transfer, efficiency and membrane flux were explored. Air side dominates the heat transfer process, while the membrane side accounts for less than 39 % of the total heat transfer resistance for the main range of membrane microstructure parameters investigated. The mass transfer is controlled by the porous membrane except for thin membrane with a thickness of less than 100 mu m. Membranes with porosity above 0.8 and as thin as possible can achieve better mass transfer efficiency and freshwater flux. Increasing mean pore diameter has a strong promotion effect on the increase of membrane flux before it reaches 150 nm, and beyond this critical value, the water vapor diffusion mechanism changes from Knudsen collision to molecular collision. Effects of different operating parameters and membrane microstructure parameters on air temperature distribution and humidity distribution were also analyzed.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Experimental and theoretical study on heat and mass transfer of hollow fiber membrane heat exchanger
    Wang, Zanshe
    Feng, Shiyu
    Li, Yun
    Gu, Zhaolin
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2009, 43 (05): : 40 - 45
  • [22] Evaluation of mass transfer for metal removal via a liquid membrane-based process in a hollow-fiber membrane contactor
    Al Shamsi, A. Y.
    Hossain, Md Monwar
    DESALINATION AND WATER TREATMENT, 2020, 201 : 240 - 249
  • [23] Guidelines for the application of a stationary model in the prediction of the overall mass transfer coefficient in a hollow fiber membrane contactor
    Trebouet, Dominique
    Burgard, Michel
    Loureiro, Jose Miguel
    SEPARATION AND PURIFICATION TECHNOLOGY, 2006, 50 (01) : 97 - 106
  • [24] Modeling and simulation of mass transfer in near-critical extraction using a hollow fiber membrane contactor
    Estay, H.
    Bocquet, S.
    Romero, J.
    Sanchez, J.
    Rios, G. M.
    Valenzuela, F.
    CHEMICAL ENGINEERING SCIENCE, 2007, 62 (21) : 5794 - 5808
  • [25] Hollow fiber membrane contactor transient experiments for the characterization of gas/liquid thermodynamics and mass transfer properties
    Porcheron, F.
    Drozdz, S.
    CHEMICAL ENGINEERING SCIENCE, 2009, 64 (02) : 265 - 275
  • [26] Mass transfer performance and correlation for CO 2 absorption into aqueous 3-diethylaminopropylamine solution in a hollow fiber membrane contactor
    Chen, Guangying
    Chen, Guangjie
    Cao, Fan
    Zhang, Rui
    Gao, Hongxia
    Liang, Zhiwu
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 152
  • [27] Sweeping gas membrane distillation: Numerical simulation of mass and heat transfer in a hollow fiber membrane module
    Karanikola, Vasiliki
    Corral, Andrea F.
    Jiang, Hua
    Saez, A. Eduardo
    Ela, Wendell P.
    Arnold, Robert G.
    JOURNAL OF MEMBRANE SCIENCE, 2015, 483 : 15 - 24
  • [28] Heat and mass transfer enhancement in a cross-flow elliptical hollow fiber membrane contactor used for liquid desiccant air dehumidification
    Huang, Si-Min
    Yang, Minlin
    JOURNAL OF MEMBRANE SCIENCE, 2014, 449 : 184 - 192
  • [29] Hollow fiber nanoporous membrane contactors for evaporative heat exchange and desalination
    Poyarkov, A. A.
    Petukhov, D. I.
    Eliseev, A. A.
    DESALINATION, 2023, 550
  • [30] Effect of wettability on mass transfer performance of hydrophobic membrane contactor
    Lu, JG
    Wang, LJ
    Liu, XD
    Li, JS
    Sun, XY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2005, 26 (05): : 912 - 917