Fresh Frozen Plasma Versus Solvent Detergent Plasma for Cardiopulmonary Bypass Priming in Neonates and Infants Undergoing Cardiac Surgery: A Retrospective Cohort Study

被引:0
作者
van Minnen, Olivier [1 ,5 ]
van den Bergh, Walter M. [1 ]
Kneyber, Martin C. J. [2 ]
Accord, Ryan E. [3 ]
Buys, Dedre [3 ]
Meier, Sascha [4 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Crit Care, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Beatrix Childrens Hosp Groningen, Div Paediat Crit Care Med, Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Cardiothorac Surg, Groningen, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, Groningen, Netherlands
[5] Univ Med Ctr Groningen, Dept Crit Care, Room R3-904,POB 30001, NL-9700 RB Groningen, Netherlands
关键词
cardiopulmonary bypass; fresh frozen plasma; solvent detergent plasma; SOLVENT/DETERGENT-TREATED PLASMA; COAGULATION; THROMBOEMBOLISM; STABILITY;
D O I
10.1053/j.jvca.2024.01.021
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Compared with fresh frozen plasma (FFP), Omniplasma has been attributed to an increased coagulation potential and an increased fibrinolytic potential. This study aimed to compare Omniplasma and FFP used for cardiopulmonary bypass (CPB) priming regarding the incidence of postoperative thrombotic or hemorrhagic complications and outcomes in pediatric patients undergoing cardiac surgery. Design: A retrospective observational cohort study Setting: This single -center study was performed at the University Medical Center Groningen. Participant: All pediatric patients up to 10 kg undergoing cardiac surgery with CPB. Interventions: Procedures in which FFP was used for CPB priming were compared with those in which Omniplasma was used. Measurements and Main Results: The primary outcome parameter was a composite endpoint consisting of the following: (1) pediatric intensive care unit (PICU) mortality, (2) thromboembolic complications, and (3) hemorrhagic complications during PICU stay. The authors included 143 procedures in the analyses, 90 (63%) in the FFP group and 53 (37%) in the Omniplasma group. The occurrence of the combined primary endpoint (FFP 20% v Omniplasma 11%, p = 0 . 18) and its components did not differ between the used CPB priming agent). Omniplasma for CPB priming was associated with decreased unfractionated heparin administration per kg bodyweight (585 IU v 510 IU, p = 0 . 03), higher preoperative and postoperative activated clotting times (ACT) discrepancy (90% v 94%, p = 0 . 03), a lower postoperative ACT value (125 v 118 seconds, p = 0 . 01), and less red blood cell transfusion per kilogram bodyweight (78 v 55 mL, p = 0 . 02). However, none of the variables differed statistically significantly in the multivariate logistic regression analyses. Conclusions: The authors did not find an association between the plasma used for CPB priming and thromboembolic and hemorrhagic complications and death in neonates and infants undergoing cardiac surgery. Omniplasma seems to be safe to use in this population.
引用
收藏
页码:1144 / 1149
页数:6
相关论文
共 19 条
  • [1] Surveillance or no surveillance ultrasonography for deep vein thrombosis and outcomes of critically ill patients: a pre-planned sub-study of the PREVENT trial
    Arabi, Yaseen M.
    Burns, Karen E. A.
    Alsolamy, Sami J.
    Alshahrani, Mohammed S.
    Al-Hameed, Fahad M.
    Arshad, Zia
    Almaani, Mohammed
    Hawa, Hassan
    Mandourah, Yasser
    Almekhlafi, Ghaleb A.
    Al Aithan, Abdulsalam
    Khalid, Imran
    Rifai, Jalal
    Rasool, Gulam
    Abdukahil, Sheryl Ann I.
    Jose, Jesna
    Afesh, Lara Y.
    Al-Dawood, Abdulaziz
    [J]. INTENSIVE CARE MEDICINE, 2020, 46 (04) : 737 - 746
  • [2] Outcomes Related to the Use of Frozen Plasma or Pooled Solvent/Detergent-Treated Plasma in Critically Ill Children
    Camazine, Maraya N.
    Karam, Oliver
    Colvin, Ryan
    Leteurtre, Stephane
    Demaret, Pierre
    Tucci, Marisa
    Muszynski, Jennifer A.
    Stanworth, Simon
    Spinella, Philip C.
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2017, 18 (05) : E215 - E223
  • [3] Current Understanding of How Extracorporeal Membrane Oxygenators Activate Haemostasis and Other Blood Components
    Doyle, Andrew J.
    Hunt, Beverley J.
    [J]. FRONTIERS IN MEDICINE, 2018, 5
  • [4] Coagulation factor content of solvent/detergent plasma compared with fresh frozen plasma
    Doyle, S
    O'Brien, P
    Murphy, K
    Fleming, C
    O'Donnell, J
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 2003, 14 (03) : 283 - 287
  • [5] High level of venous thromboembolism in critically ill trauma patients despite early and well-driven thromboprophylaxis protocol
    Hamada, S. R.
    Espina, C.
    Guedj, T.
    Buaron, R.
    Harrois, A.
    Figueiredo, S.
    Duranteau, J.
    [J]. ANNALS OF INTENSIVE CARE, 2017, 7
  • [6] Effects of solvent/detergent-treated plasma and fresh-frozen plasma on haemostasis and fibrinolysis in complex coagulopathy following open-heart surgery
    Haubelt, H
    Blome, M
    Kiessling, AH
    Isgro, F
    Bach, J
    Saggau, W
    Hellstern, P
    [J]. VOX SANGUINIS, 2002, 82 (01) : 9 - 14
  • [7] Low Incidence of Hyperfibrinolysis and Thromboembolism in 195 Primary Liver Transplantations Transfused with Solvent/Detergent-Treated Plasma
    Haugaa, Hakon
    Taraldsrud, Eli
    Nyrerod, Hans Christian
    Tonnessen, Tor Inge
    Foss, Aksel
    Solheim, Bjarte G.
    [J]. CLINICAL MEDICINE & RESEARCH, 2014, 12 (1-2) : 27 - 32
  • [8] Stability of solvent/detergent-treated plasma and single-donor fresh-frozen plasma during 48h after thawing
    Heger, A
    Römisch, J
    Svae, TE
    [J]. TRANSFUSION AND APHERESIS SCIENCE, 2005, 33 (03) : 257 - 267
  • [9] HOROWITZ B, 1992, BLOOD, V79, P826
  • [10] Comparison of the Coagulation Effect Achieved by OctaplasLG Versus Fresh Frozen Plasma in Pediatric Cardiac Surgical Patients
    Kalsi, Amanpreet S.
    Al-Azzawi, Omar
    Gill, Ravi
    [J]. CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2018, 24 (08) : 1327 - 1332