The treatment of raw foul air that could escape to the atmosphere from the head space of the incoming wastewater sewer lines into a Southern California Water Resource Recovery Facility was evaluated by using a 1/20th scale pilot unit consisting of three different granular activated carbon filter technologies, operating side by side, under similar operating conditions, each having an average 3.8-s contact time. The three activated carbon filters contained each 0.07 m3 of coconut, coal, and coconut mixed with permanganate media. The foul air entering the granular activated carbon filters contained 82% to 83% relative humidity. No moisture removal mechanism was used prior to treatment. The removal of six different odor characters from eight chemical odorants present in the foul air were assessed. These were rotten egg (hydrogen sulfide), rotten vegetables (methyl mercaptan), canned corn (dimethyl sulfide), rotten garlic (dimethyl disulfide), earthy/musty (2-methyl isoborneol and 2-isopropyl 3-methoxy pyrazine), and fecal (skatole and indole). This is the first time a study evaluates the removal of specific odors by simultaneously employing sensory analyses using the odor profile method, which defines the different odor characters and intensities, together with chemical analyses of the odorants causing these odors. The results show that the three granular activated carbon filters, before hydrogen sulfide breakthrough, provided significant improvement in odor intensity and odorant removal. Breakthrough was reached after 57 days for the coconut mixed with permanganate, 107 days for the coconut, and 129 days for the coal granular activated carbon filter. Breakthrough (the critical saturation point of the activated carbon media) was considered reached when the hydrogen sulfide percentage removal diminished to 90% and continued downward. The coconut mixed with permanganate granular activated carbon filter provided the best treatment among the media tested, achieving very good reduction of odorants, as measured by chemical analyses, and reasonable removal of odor intensities, as measured by the odor profile method. The coconut mixed with permanganate granular activated carbon is recommended for short-term odor control systems at sewer networks or emergency plant maintenance situations given its shorter time to breakthrough compared with the other granular activated carbons. The coal and coconut granular activated carbon filters are generally used as the last stage of an odor treatment system. Because of the observed poor to average performance in removing odorants other than hydrogen sulfide, the treatment stage(s) prior to the use of these granulated activated carbons should provide a good methyl mercaptan removal of at least 90% in order to avoid the formation of dimethyl disulfide, which, in the presence of moisture in the carbon filter, emit the characteristic rotten garlic odor. The differences observed between the performances based on odorant removal by chemical analysis compared with those based on sensorial analyses by the odor profile method indicate that both analyses are required to understand more fully the odor dynamics.Practitioner Points Three virgin granulated activated carbon media were evaluated in a field pilot unit using raw collections foul air. Coal, coconut, and coconut mixed with permanganate were tested until breakthrough. Samples were analyzed both chemically (odorants) and sensorially (odors). Coconut mixed with permanganate proved to be the media that better reduced odorants and odors. Separate granular activated carbon media treating collections foul air have been tested, showing different treatment efficiencies. Coconut mixed 50/50 with permanganate provided the best removal of the typical odorants present in water resource recovery facilities. image
引用
收藏
页数:13
相关论文
共 10 条
  • [1] Composition and stability of bacterial communities associated with granular activated carbon and anthracite filters in a pilot scale municipal drinking water treatment facility
    Shirey, T. B.
    Thacker, R. W.
    Olson, J. B.
    JOURNAL OF WATER AND HEALTH, 2012, 10 (02) : 244 - 255
  • [2] Use of granular activated carbon filters associated with microorganisms to remove pharmaceuticals in drinking water treatment
    Borges, Rivea Medri
    Minillo, Alessandro
    de Macedo Lemos, Eliana Gertrudes
    Alves do Prado, Heloiza Ferreira
    Tangerino, Edson Pereira
    ENGENHARIA SANITARIA E AMBIENTAL, 2016, 21 (04) : 709 - 720
  • [3] Removal of atrazine herbicide through granular activated carbon filters associated with microorganisms in drinking water treatment
    Canevaroli, Miriam Ruiz
    de Macedo Lemos, Eliana Gertrudes
    Pires de Oliveira, Kelly Mari
    Isique, William Deodato
    Suarez, Yzel Rondon
    Minillo, Alessandro
    ENGENHARIA SANITARIA E AMBIENTAL, 2021, 26 (02) : 263 - 272
  • [4] Production of granular activated carbon by thermal air oxidation of biomass charcoal/biochar for water treatment in rural communities: A mechanistic investigation
    Xiao, Feng
    Bedane, Alemayehu H.
    Mallula, Swetha
    Sasi, Pavankumar Challa
    Alinezhad, Ali
    Soli, Dana
    Hagen, Zachary M.
    Mann, Michael D.
    CHEMICAL ENGINEERING JOURNAL ADVANCES, 2020, 4
  • [5] Evaluation of chemical washing for granular activated carbon during drinking water treatment
    Woo, Hyoungmin
    Kim, Hyun-Chul
    Lee, Sangje
    Maeng, Sung Kyu
    DESALINATION AND WATER TREATMENT, 2017, 97 : 117 - 125
  • [6] Optimisation and significance of ATP analysis for measuring active biomass in granular activated carbon filters used in water treatment
    Magic-Knezev, A
    van der Kooij, D
    WATER RESEARCH, 2004, 38 (18) : 3971 - 3979
  • [7] Different Effects of Mineral Versus Vegetal Granular Activated Carbon Filters on the Microbial Community Composition of a Drinking Water Treatment Plant
    Bruno, Antonia
    Sandionigi, Anna
    Magnani, Davide
    Bernasconi, Marzia
    Pannuzzo, Bruno
    Consolandi, Clarissa
    Camboni, Tania
    Labra, Massimo
    Casiraghi, Maurizio
    FRONTIERS IN ECOLOGY AND EVOLUTION, 2021, 9
  • [8] Demonstration-scale evaluation of ozone-biofiltration-granular activated carbon advanced water treatment for managed aquifer recharge
    Hogard, Samantha
    Salazar-Benites, Germano
    Pearce, Robert
    Nading, Tyler
    Schimmoller, Larry
    Wilson, Christopher
    Heisig-Mitchell, Jamie
    Bott, Charles
    WATER ENVIRONMENT RESEARCH, 2021, 93 (08) : 1157 - 1172
  • [9] Performance evaluation and optimization of a fluidized three-dimensional electrode reactor combining pre-exposed granular activated carbon as a moving particle electrode for greywater treatment
    Jung, Kyung-Won
    Hwang, Min-Jin
    Park, Dae-Seon
    Ahn, Kyu-Hong
    SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 156 : 414 - 423
  • [10] Performance evaluation of a hybrid system for efficient palm oil mill effluent treatment via an air-cathode, tubular upflow microbial fuel cell coupled with a granular activated carbon adsorption
    Tee, Pei-Fang
    Abdullah, Mohammad Omar
    Tan, Ivy Ai Wei
    Amin, Mohamed Afizal Mohamed
    Nolasco-Hipolito, Cirilo
    Bujang, Kopli
    BIORESOURCE TECHNOLOGY, 2016, 216 : 478 - 485