Based on the combination of fluid-solid interaction mechanism model and surrogate model for peristaltic pump performance analysis and multi-objective optimization design

被引:4
作者
Liu, Fuwen [1 ,2 ]
Gong, Zhuangzhuang [1 ,2 ]
Ma, Xinao [1 ,2 ]
Zhang, Yanfeng [3 ,4 ]
Song, Xueguan [1 ,2 ]
机构
[1] Dalian Univ Technol, Sch Mech Engn, Dalian 116023, Peoples R China
[2] Dalian Univ Technol, State Key Lab High Performance Precis Mfg, Dalian 116023, Peoples R China
[3] Baoding Lead Fluid Technol Co Ltd, Baoding 071000, Peoples R China
[4] Hebei Prov Fluid Precis Transmission Technol Innov, Sanhe, Peoples R China
基金
中国国家自然科学基金;
关键词
Fluid -solid interaction; MIGA; Multi -objective optimization; Peristaltic pump; Surrogate model;
D O I
10.1016/j.aei.2024.102675
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The peristaltic pump is a high precision biomimetic pump widely used in the medical industry. However, the pump has flow pulsation, due to its special structure. The serious flow pulsation can dramatically reduce delivery accuracy and stability. Meanwhile, the service life of the peristaltic pump is affected by the conveying capacity. The flow pulsation degree and transportation capacity of the pump are affected by the structural parameters of its key components. An in-depth study of peristaltic pumps is necessary in order to reduce the degree of pulsation and increase service life. The paper skillfully combines the fluid-solid interaction (FSI) mechanism model with the surrogate model to deeply study the influence of key structural parameters of the peristaltic pump on its performance, and the multi-objective optimization design of the pump is carried out by using the multi-island genetic algorithm (MIGA). The results show that for the average flow, the hose inner diameter has the greatest influence, followed by the working circle diameter. The roller diameter has very little effect. The hose inner diameter and working circle diameter have a minor coupling effect on the roller diameter. It slightly affects the trend of the average flow rate with the roller diameter. The hose inner diameter also has a slight coupling effect on the working circle diameter. For the instantaneous flow rate percentage, the effects of all three key parameters are significant. The hose inner diameter has an obvious coupling effect on the working circle diameter and the roller diameter, which affects the trend of the instantaneous flow rate percentage with the working circle diameter and the roller diameter. The optimized pump has a 43.3% decrease in the percentage of flow rate and a 59.6% increase in the average flow rate, indicating significant improvements in transport stability and capacity.
引用
收藏
页数:18
相关论文
共 68 条
[1]   Catalytic effects on peristaltic flow of Jeffrey fluid through a flexible porous duct under oblique magnetic field: Application in biomimetic pumps for hazardous materials [J].
Ajithkumar, M. ;
Kuharat, S. ;
Beg, O. Anwar ;
Sucharitha, G. ;
Lakshminarayana, P. .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 49
[2]   Investigation of a conducting Casson fluid flow through a porous flexible microfluidic channel with catalytic effects: application in pharmaceutical fluid processing [J].
Ajithkumar, M. ;
Vajravelu, K. ;
Sucharitha, G. ;
Lakshminarayana, P. .
EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (03)
[3]   Peristaltic flow of a bioconvective sutterby nanofluid in a flexible microchannel with compliant walls: Application to hemodynamic instability [J].
Ajithkumar, M. ;
Vajravelu, K. ;
Sucharitha, G. ;
Lakshminarayana, P. .
PHYSICS OF FLUIDS, 2023, 35 (12)
[4]   Peristaltic flow of bioconvective Ree-Eyring nanofluid through an inclined elastic channel with partial slip effects [J].
Ajithkumar, M. ;
Lakshminarayana, P. ;
Vajravelu, K. .
JOURNAL OF APPLIED PHYSICS, 2023, 134 (15)
[5]   MHD peristaltic flow of chemically reactive casson nanofluid in a nonuniform porous inclined flexible channel with cross-diffusion effects [J].
Ajithkumar, M. ;
Lakshminarayana, P. .
INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2023, 37 (25)
[6]   Peristaltic transport of MHD Ree-Eyring fluid through a flexible channel under the influence of activation energy [J].
Ajithkumar, M. ;
Lakshminarayana, P. ;
Vajravelu, K. .
PHYSICS OF FLUIDS, 2023, 35 (06)
[7]   Chemically reactive MHD peristaltic flow of Jeffrey nanofluid via a vertical porous conduit with complaint walls under the effects of bioconvection and double diffusion [J].
Ajithkumar, M. ;
Lakshminarayana, P. .
INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2024, 38 (16)
[8]   Diffusion effects on mixed convective peristaltic flow of a bi-viscous Bingham nanofluid through a porous medium with convective boundary conditions [J].
Ajithkumar, M. ;
Lakshminarayana, P. ;
Vajravelu, K. .
PHYSICS OF FLUIDS, 2023, 35 (03)
[9]   Electro osmotically interactive biological study of thermally stratified micropolar nanofluid flow for Copper and Silver nanoparticles in a microchannel [J].
Akbar, Noreen Sher ;
Rafiq, Maimona ;
Muhammad, Taseer ;
Alghamdi, Metib .
SCIENTIFIC REPORTS, 2024, 14 (01)
[10]   Physical aspects of electro osmotically interactive Cilia propulsion on symmetric plus asymmetric conduit flow of couple stress fluid with thermal radiation and heat transfer [J].
Akbar, Noreen Sher ;
Muhammad, Taseer .
SCIENTIFIC REPORTS, 2023, 13 (01)