A dose titration protocol for once-daily insulin glargine 300 U/mL for the treatment of diabetes mellitus in dogs

被引:2
作者
Tardo, Antonio Maria [1 ]
Fleeman, Linda Mary [2 ]
Fracassi, Federico [1 ]
Berg, Alisa Saule [3 ]
Guarino, Aria L. [3 ,4 ]
Gilor, Chen [3 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Bologna, Italy
[2] Anim Diabet Australia, Collingwood, Vic, Australia
[3] Univ Florida, Coll Vet Med, Dept Small Anim Clin Sci, 2015 SW 16th Ave, Gainesville, FL 32611 USA
[4] BluePearl Pet Hosp, Rockville, MD USA
关键词
basal-bolus insulin therapy; continuous glucose monitoring; diabetic dogs; FreeStyle Libre; Toujeo; POSTPRANDIAL GLUCOSE; GLYCEMIC CONTROL; NPH INSULIN; TIME-ACTION; DETEMIR; ANALOGS; VARIABILITY; PEOPLE; TYPE-1; DIET;
D O I
10.1111/jvim.17106
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundIn purpose-bred dogs, insulin glargine 300 U/mL (IGla300) has long duration of action, peakless time-action profile, and low potency, making it suitable for use as a basal insulin. HypothesisTo evaluate IGla300 in client-owned diabetic dogs monitored using a flash glucose monitoring system (FGMS). AnimalsNinety-five client-owned diabetic dogs, newly diagnosed or previously treated with other insulin formulations, with or without concurrent diseases. MethodsProspective multi-institutional study. Clinical signs and standardized assessment of FGMS data, using treatment and monitoring guidelines established a priori, guided dose adjustments and categorization into levels of glycemic control. ResultsThe initial IGla300 dose was 0.5 U/Kg q24h for newly diagnosed dogs and (median dose [range]) 0.8 U/Kg (0.2-2.5) q24h for all dogs. Glycemic control was classified as good or excellent in 87/95 (92%) dogs. The IGla300 was administered q24h (1.9 U/kg [0.2-5.2]) and q12h (1.9 U/kg/day [0.6-5.0]) in 56/95 (59%) and 39/95 (41%) dogs, respectively. Meal-time bolus injections were added in 5 dogs (0.5 U/kg/injection [0.3-1.0]). Clinical hypoglycemia occurred in 6/95 (6%) dogs. Dogs without concurrent diseases were more likely to receive IGla300 q24h than dogs with concurrent diseases (72% vs 50%, respectively; P = .04). Conclusions and Clinical ImportanceInsulin glargine 300 U/mL can be considered a suitable therapeutic option for once-daily administration in diabetic dogs. Clinicians should be aware of the low potency and wide dose range of IGla300. In some dogs, twice-daily administration with or without meal-time bolus injections may be necessary to achieve glycemic control. Monitoring with FGMS is essential for dose titration of IGla300.
引用
收藏
页码:2120 / 2128
页数:9
相关论文
共 43 条
[1]   New Insulin Glargine 300 Units.mL-1 Provides a More Even Activity Profile and Prolonged Glycemic Control at Steady State Compared With Insulin Glargine 100 Units.mL-1 [J].
Becker, Reinhard H. A. ;
Dahmen, Raphael ;
Bergmann, Karin ;
Lehmann, Anne ;
Jax, Thomas ;
Heise, Tim .
DIABETES CARE, 2015, 38 (04) :637-643
[2]  
Behrend E, 2018, J AM ANIM HOSP ASSOC, V54, P1, DOI [10.5326/JAAHA-MS-6822, 10.5326/jaaha-ms-6822]
[3]   Effects of six carbohydrate sources on dog diet digestibility and post-prandial glucose and insulin response [J].
Carciofi, A. C. ;
Takakura, F. S. ;
de-Oliveira, L. D. ;
Teshima, E. ;
Jeremias, J. T. ;
Brunetto, M. A. ;
Prada, F. .
JOURNAL OF ANIMAL PHYSIOLOGY AND ANIMAL NUTRITION, 2008, 92 (03) :326-336
[4]   Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs [J].
Corradini, S. ;
Pilosio, B. ;
Dondi, F. ;
Linari, G. ;
Testa, S. ;
Brugnoli, F. ;
Gianella, P. ;
Pietra, M. ;
Fracassi, F. .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 2016, 30 (04) :983-988
[5]   Continuous Glucose Monitoring in Dogs and Cats Application of New Technology to an Old Problem [J].
Del Baldo, Francesca ;
Fracassi, Federico .
VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2023, 53 (03) :591-613
[6]   Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations [J].
Del Baldo, Francesca ;
Fracassi, Federico ;
Pires, Jully ;
Tardo, Antonio Maria ;
Malerba, Eleonora ;
Manassero, Elisa ;
Gilor, Chen .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (03) :1279-1287
[7]   Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus [J].
Del Baldo, Francesca ;
Canton, Claudia ;
Testa, Silvia ;
Swales, Harry ;
Drudi, Ignazio ;
Golinelli, Stefania ;
Fracassi, Federico .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (06) :2296-2305
[8]   A diet lower in digestible carbohydrate results in lower postprandial glucose concentrations compared with a traditional canine diabetes diet and an adult maintenance diet in healthy dogs [J].
Elliott, K. F. ;
Rand, J. S. ;
Fleeman, L. M. ;
Morton, J. M. ;
Litster, A. L. ;
Biourge, V. C. ;
Markwell, P. J. .
RESEARCH IN VETERINARY SCIENCE, 2012, 93 (01) :288-295
[9]  
European Society of Veterinary Endocrinology, 2020, PROJECT ALIVE TERM D
[10]   Pharmacodynamics and pharmacokinetics of insulin detemir and insulin glargine 300 U/mL in healthy dogs [J].
Fink, H. ;
Herbert, C. ;
Gilor, C. .
DOMESTIC ANIMAL ENDOCRINOLOGY, 2018, 64 :17-30