Safety and Effectiveness of Transthoracic Echocardiography and Transesophageal Echocardiography in the Interventional Closure of Atrial Septal Defects in Children: A Systematic Review and Meta-Analysis

被引:0
|
作者
Lu, Haiyan [1 ]
Wang, Jindong [2 ]
Zhou, Lingjuan [1 ]
Liu, Lian [3 ]
机构
[1] Wenzhou Med Univ, Taizhou Hosp Zhejiang Prov, Dept Ultrasound, Taizhou 318050, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Taizhou Hosp Zhejiang Prov, Qual Improvement Off, Taizhou 318050, Zhejiang, Peoples R China
[3] Wenzhou Med Univ, Taizhou Hosp Zhejiang Prov, Dept Pediat, Taizhou 318050, Zhejiang, Peoples R China
关键词
atrial septal defect; meta-analysis; randomized controlled trial; transthoracic echocardiography; transesophageal echocardiography; TRANSCATHETER CLOSURE; EFFICACY; GUIDANCE;
D O I
10.59958/hsf.7353
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: : Through this meta-analysis, a systematic review was conducted on the effects of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) in the interventional closure of atrial septal defects (ASDs) in children. Methods: : We searched papers in the PubMed, Web of Science, Cochrane Library, Google Scholar, CNKI, Wanfang, Embase, and VIP databases. The search time limit was from the establishment of the database to May 2023. Randomized controlled trials on the effect of TTE and TEE in the interventional closure of ASD in children were screened. The included results were integrated and analyzed, and ReviewManager 5.4 was used for the meta-analysis. Results: : Six studies with a total of 253 patients with ASD were included in this meta-analysis. Results showed that the surgical success rate in each study was more than 90%, with no difference between TEE and TTE (p p = 0.11; risk ratio (RR) = 0.96, 95% confidence interval (CI): 0.89 to 1.04). The surgery time of TTE was significantly shorter than that of TEE (standard mean difference (SMD) = -1.52, 95% CI: -2.30 to -0.74). The fluoroscopy time of TTE was shorter than that of TEE (SMD = -0.69, 95% CI: -1.08 to -0.30). We found no significant difference in complication rates (RR = 0.36, 95% CI: 0.09 to 1.39). Conclusion: : The combination of TTE and TEE is important during surgery, and postoperative complications are relatively small. The surgery time and fluoroscopy time of TTE are shorter than those of TEE.
引用
收藏
页码:E668 / E679
页数:12
相关论文
共 50 条
  • [21] Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects Reporting a single center experience from Saudi Arabia
    Azhar, Ahmad S.
    SAUDI MEDICAL JOURNAL, 2016, 37 (11) : 1196 - 1205
  • [22] Role of Echocardiography in the Diagnosis and Interventional Management of Atrial Septal Defects
    Rao, P. Syamasundar
    DIAGNOSTICS, 2022, 12 (06)
  • [23] Comparative effectiveness of devices for transcatheter closure of atrial septal defects: Systematic review and network meta-analysis
    Vishwanath, Varnita
    Akseer, Selai
    Frankfurter, Claudia
    Reza, Seleman
    Farrell, Ashley
    Horlick, Eric
    Abrahamyan, Lusine
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2022, 115 (12) : 664 - 674
  • [24] Accuracy of Transthoracic Echocardiography in Assessing Retro-aortic Rim prior to Device Closure of Atrial Septal Defects
    O'Byrne, Michael L.
    Glatz, Andrew C.
    Goldberg, David J.
    Shinohara, Russell
    Dori, Yoav
    Rome, Jonathan J.
    Gillespie, Matthew J.
    CONGENITAL HEART DISEASE, 2015, 10 (04) : E146 - E154
  • [25] Intracardiac vs transesophageal echocardiography for left atrial appendage occlusion: An updated systematic review and meta-analysis
    Serpa, Frans
    Rivera, Andre
    Fernandes, Julia M.
    Braga, Marcelo Antonio Pinheiro
    Araujo, Beatriz
    Felix, Iuri Ferreira
    Ferro, Enrico Giuseppe
    Zimetbaum, Peter J.
    d'Avila, Andre
    Kramer, Daniel B.
    HEART RHYTHM, 2025, 22 (03) : 786 - 795
  • [26] Percutaneous atrial septal defect closure using transesophageal echocardiography without fluoroscopy in a pregnant woman: a case report
    Prakoso, Radityo
    Ariani, Rina
    Lilyasari, Oktavia
    Kurniawati, Yovi
    Siagian, Sisca Natalia
    Sakidjan, Indriwanto
    Roebiono, Poppy Soerwianti
    Rahajoe, Anna Ulfah
    Lelya, Olfi
    Sembiring, Aditya Agita
    Harimurti, Ganesja Moelia
    MEDICAL JOURNAL OF INDONESIA, 2020, 29 (02) : 228 - 232
  • [27] Analysis of the therapeutic effect of transesophageal echocardiography-guided percutaneous device closure of atrial septal defects via the right internal jugular vein in children
    Gao, Minglei
    Li, Zipu
    Zhao, Ye
    Wen, Ping
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (07): : 1357 - 1363
  • [28] Intracardiac echocardiography to guide closure of atrial septal defects in children less than 15 kilograms
    Patel, Angira
    Cao, Qi-Ling
    Koenig, Peter R.
    Hijazi, Ziyad M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (02) : 287 - 291
  • [29] Intracardiac vs. transesophageal echocardiography for guiding transcatheter closure of interatrial communications: a systematic review and meta-analysis
    Lan, Qingsu
    Wu, Fengchao
    Ye, Xudong
    Wang, Shaohua
    Zhong, Jingquan
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [30] Experience with use of multiplane transesophageal echocardiography to guide closure of atrial septal defects using the Amplatzer device
    Figueroa, MI
    Balaguru, D
    McClure, C
    Kline, CH
    Radtke, NAK
    Shirali, GS
    PEDIATRIC CARDIOLOGY, 2002, 23 (04) : 430 - 436