Correlations on heat-transfer rate and friction factor using radial and axial v-cut geometry on a twisted tape in a double-pipe heat exchanger

被引:4
|
作者
Singh, Sanjay Kumar [1 ]
Kacker, Ruchin [1 ]
Gautam, Satyam Shivam [2 ]
Tandon, Sourabh [3 ]
机构
[1] Sagar Inst Sci & Technol, Dept Mech Engn, Bhopal 462036, MP, India
[2] North Eastern Reg Inst Sci & Technol NERIST, Dept Mech Engn, Itanagar, Arunachal Prade, India
[3] Vaishnavi Inst Technol & Sci, Dept Mech Engn, Bhopal, MP, India
关键词
Twisted tape inserts; double-pipe heat exchanger; heat transfer enhancement; Nusselt number; friction factor; performance evaluation criteria; TUBE; FLOW;
D O I
10.1177/09544089241252047
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study explores the transformative potential of varying radial and axial v-cut angles within twisted tape inserts in the context of heat transfer enhancement within a double-pipe heat exchanger. The research is driven by the need to enhance energy efficiency in heat exchange systems, with a focus on understanding how v-cut angles influence heat-transfer rates, friction factors, and overall performance. Using water as the working medium, a comprehensive experimental investigation is conducted across a Reynolds number range of 5500-10,000. The findings reveal compelling correlations between the Nusselt number (Nu), friction factor (f), and performance evaluation criteria concerning different v-cut angles within the twisted tape inserts. Remarkably, the study underscores the pivotal role of radial v-cut twisted tapes in elevating heat exchanger performance, surpassing even axial v-cut configurations. The Nusselt number achieves its pinnacle (96.51) at a Reynolds number of 10,000, whereas the highest friction factor (0.0582) and performance evaluation criteria (1.65) emerge at a Reynolds number of 5500, specifically with a 45-degree radial v-cut angle. This configuration showcases remarkable enhancements in the Nusselt number (98.68%), friction factor (38.87%), and performance evaluation criterion (39.36%) compared to a plain tube, underlining the transformative potential of optimized twisted tape inserts. The presented study offers more than theoretical insights; it provides practical guidelines for designing heat exchangers with superior performance. Derived correlations for the Nusselt number and friction factor, established through regression analysis involving key parameters such as Reynolds number (Re), Prandtl number (Pr), radial v-cut angle (phi), and axial v-cut angle (theta), demonstrate robust results within a narrow range of +/- 5% for the Nusselt number and +/- 7% for the friction factor. In summary, this investigation not only advances our understanding of heat transfer enhancement but also presents tangible pathways for implementing enhanced heat exchanger designs, contributing significantly to energy-efficient thermal systems.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Numerical evaluation of the effect of using twisted tapes as turbulator with various geometries in both sides of a double-pipe heat exchanger
    Noorbakhsh, Mehdi
    Zaboli, Mohammad
    Ajarostaghi, Seyed Soheil Mousavi
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 140 (03) : 1341 - 1353
  • [42] Development of ANN prediction model for estimation of heat transfer utilizing rectangular-toothed v-cut twisted tape
    Singh, Sanjay Kumar
    Kacker, Ruchin
    Gautam, Satyam Shivam
    Tamang, Santosh Kumar
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024,
  • [43] Modeling of triangular perforated twisted tape with V-Cuts in double pipe heat exchanger
    Kumar, Rishabh
    Nandan, Gopal
    Dwivedi, Gaurav
    Shukla, Anoop Kumar
    Shrivastava, Ramakant
    MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 5389 - 5395
  • [44] Double-sided delta-wing tape inserts to enhance convective heat transfer and fluid flow characteristics of a double-pipe heat exchanger
    Wijayanta, Agung Tri
    Yaningsih, Indri
    Aziz, Muhammad
    Miyazaki, Takahiko
    Koyama, Shigeru
    APPLIED THERMAL ENGINEERING, 2018, 145 : 27 - 37
  • [45] Heat transfer and pressure drop characteristics in a circular tube fitted with and without V-cut twisted tape insert
    Murugesan, P.
    Mayilsamy, K.
    Suresh, S.
    Srinivasan, P. S. S.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2011, 38 (03) : 329 - 334
  • [46] Investigation of Overlapped Twisted Tapes Inserted in a Double-Pipe Heat Exchanger Using Two-Phase Nanofluid
    Ghalambaz, Mehdi
    Arasteh, Hossein
    Mashayekhi, Ramin
    Keshmiri, Amir
    Talebizadehsardari, Pouyan
    Yaici, Wahiba
    NANOMATERIALS, 2020, 10 (09) : 1 - 17
  • [47] An experimental study on MWCNT–water nanofluids flow and heat transfer in double-pipe heat exchanger using porous media
    Ahmad Moradi
    Davood Toghraie
    Amir Homayoon Meghdadi Isfahani
    Ali Hosseinian
    Journal of Thermal Analysis and Calorimetry, 2019, 137 : 1797 - 1807
  • [48] Experimental study of exergetic performance of Al2O3 nanofluid in a double-pipe heat exchanger fitted by a new modified twisted tape
    Shirazi, Robab
    HEAT TRANSFER, 2020, 49 (05) : 2813 - 2830
  • [49] Heat transfer augmentation techniques in forced flow V-trough solar collector equipped with V-cut and square cut twisted tape
    Saravanan, A.
    Jaisankar, S.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 140 : 59 - 70
  • [50] EAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF PIPE-IN-PIPE HEAT EXCHANGER FITTED WITH VARIANT PLAIN TAPE INSERT
    Sivasubramaniam, Arthanari Ponnusamy
    Goundar, Mayilsamy Kavandappa
    Perumal, Murugesan
    THERMAL SCIENCE, 2020, 24 (01): : 623 - 633