Correlations on heat-transfer rate and friction factor using radial and axial v-cut geometry on a twisted tape in a double-pipe heat exchanger

被引:4
|
作者
Singh, Sanjay Kumar [1 ]
Kacker, Ruchin [1 ]
Gautam, Satyam Shivam [2 ]
Tandon, Sourabh [3 ]
机构
[1] Sagar Inst Sci & Technol, Dept Mech Engn, Bhopal 462036, MP, India
[2] North Eastern Reg Inst Sci & Technol NERIST, Dept Mech Engn, Itanagar, Arunachal Prade, India
[3] Vaishnavi Inst Technol & Sci, Dept Mech Engn, Bhopal, MP, India
关键词
Twisted tape inserts; double-pipe heat exchanger; heat transfer enhancement; Nusselt number; friction factor; performance evaluation criteria; TUBE; FLOW;
D O I
10.1177/09544089241252047
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study explores the transformative potential of varying radial and axial v-cut angles within twisted tape inserts in the context of heat transfer enhancement within a double-pipe heat exchanger. The research is driven by the need to enhance energy efficiency in heat exchange systems, with a focus on understanding how v-cut angles influence heat-transfer rates, friction factors, and overall performance. Using water as the working medium, a comprehensive experimental investigation is conducted across a Reynolds number range of 5500-10,000. The findings reveal compelling correlations between the Nusselt number (Nu), friction factor (f), and performance evaluation criteria concerning different v-cut angles within the twisted tape inserts. Remarkably, the study underscores the pivotal role of radial v-cut twisted tapes in elevating heat exchanger performance, surpassing even axial v-cut configurations. The Nusselt number achieves its pinnacle (96.51) at a Reynolds number of 10,000, whereas the highest friction factor (0.0582) and performance evaluation criteria (1.65) emerge at a Reynolds number of 5500, specifically with a 45-degree radial v-cut angle. This configuration showcases remarkable enhancements in the Nusselt number (98.68%), friction factor (38.87%), and performance evaluation criterion (39.36%) compared to a plain tube, underlining the transformative potential of optimized twisted tape inserts. The presented study offers more than theoretical insights; it provides practical guidelines for designing heat exchangers with superior performance. Derived correlations for the Nusselt number and friction factor, established through regression analysis involving key parameters such as Reynolds number (Re), Prandtl number (Pr), radial v-cut angle (phi), and axial v-cut angle (theta), demonstrate robust results within a narrow range of +/- 5% for the Nusselt number and +/- 7% for the friction factor. In summary, this investigation not only advances our understanding of heat transfer enhancement but also presents tangible pathways for implementing enhanced heat exchanger designs, contributing significantly to energy-efficient thermal systems.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Experimental investigation on the hydrothermal performance of a double-pipe heat exchanger using helical tape insert
    Salem, M. R.
    Eltoukhey, M. B.
    Ali, R. K.
    Elshazly, K. M.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 124 : 496 - 507
  • [32] Heat transfer enhancement in a double-pipe helical heat exchanger using spring wire insert and nanofluid
    Sharaf, Maisa A.
    Marzouk, S. A.
    Aljabr, Ahmad
    Almehmadi, Fahad Awjah
    Kaood, Amr
    Alqaed, Saeed
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (10) : 5017 - 5033
  • [33] Experimental and numerical study on heat transfer enhancement using ultrasonic vibration in a double-pipe heat exchanger
    Setareh, Milad
    Saffar-Avval, Majid
    Abdullah, Amir
    APPLIED THERMAL ENGINEERING, 2019, 159
  • [34] Availability Prediction of a Double Pipe Heat Exchanger Using Twisted Tape and Nanofluids
    Alhussen, Abdullah Yousef
    Hussein, Adnan M.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2024, 42 (05) : 1622 - 1632
  • [35] Exploring the combined influence of primary and secondary vortex flows on heat transfer enhancement and friction factor in a dimpled configuration twisted tape with double pipe heat exchanger using SiO2 nano fluid
    Chaurasiya P.K.
    Heeraman J.
    Singh S.K.
    Verma T.N.
    Dwivedi G.
    Shukla A.K.
    International Journal of Thermofluids, 2024, 22
  • [36] Numerical investigation of turbulent CuO-water nanofluid inside heat exchanger enhanced with double V-cut twisted tapes
    Nakhchi, M. E.
    Esfahani, J. A.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (05) : 2535 - 2545
  • [37] Enhancing heat transfer in a double-tube heat exchanger using perforated twisted tape and nanofluid
    Marzouk, S. A.
    Aljabr, Ahmad
    Almehmadi, Fahad Awjah
    Sharaf, Maisa A.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2025,
  • [38] Experimental heat transfer and pressure drop study on typical, perforated, V-cut and U-cut twisted tapes in a helically corrugated heat exchanger
    Hasanpour, A.
    Farhadi, M.
    Sedighi, K.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 71 : 126 - 136
  • [39] Heat Transfer and Friction Factor in a Tube Equipped with U-cut Twisted Tape Insert
    Murugesan, P.
    Mayilsamy, K.
    Suresh, S.
    JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2011, 5 (06) : 559 - 565
  • [40] Heat transfer enhancement through nano-fluids and twisted tape insert with rectangular cut on its rib in a double pipe heat exchanger
    Gnanavel, C.
    Saravanan, R.
    Chandrasekaran, M.
    MATERIALS TODAY-PROCEEDINGS, 2020, 21 : 865 - 869