Correlations on heat-transfer rate and friction factor using radial and axial v-cut geometry on a twisted tape in a double-pipe heat exchanger

被引:4
|
作者
Singh, Sanjay Kumar [1 ]
Kacker, Ruchin [1 ]
Gautam, Satyam Shivam [2 ]
Tandon, Sourabh [3 ]
机构
[1] Sagar Inst Sci & Technol, Dept Mech Engn, Bhopal 462036, MP, India
[2] North Eastern Reg Inst Sci & Technol NERIST, Dept Mech Engn, Itanagar, Arunachal Prade, India
[3] Vaishnavi Inst Technol & Sci, Dept Mech Engn, Bhopal, MP, India
关键词
Twisted tape inserts; double-pipe heat exchanger; heat transfer enhancement; Nusselt number; friction factor; performance evaluation criteria; TUBE; FLOW;
D O I
10.1177/09544089241252047
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study explores the transformative potential of varying radial and axial v-cut angles within twisted tape inserts in the context of heat transfer enhancement within a double-pipe heat exchanger. The research is driven by the need to enhance energy efficiency in heat exchange systems, with a focus on understanding how v-cut angles influence heat-transfer rates, friction factors, and overall performance. Using water as the working medium, a comprehensive experimental investigation is conducted across a Reynolds number range of 5500-10,000. The findings reveal compelling correlations between the Nusselt number (Nu), friction factor (f), and performance evaluation criteria concerning different v-cut angles within the twisted tape inserts. Remarkably, the study underscores the pivotal role of radial v-cut twisted tapes in elevating heat exchanger performance, surpassing even axial v-cut configurations. The Nusselt number achieves its pinnacle (96.51) at a Reynolds number of 10,000, whereas the highest friction factor (0.0582) and performance evaluation criteria (1.65) emerge at a Reynolds number of 5500, specifically with a 45-degree radial v-cut angle. This configuration showcases remarkable enhancements in the Nusselt number (98.68%), friction factor (38.87%), and performance evaluation criterion (39.36%) compared to a plain tube, underlining the transformative potential of optimized twisted tape inserts. The presented study offers more than theoretical insights; it provides practical guidelines for designing heat exchangers with superior performance. Derived correlations for the Nusselt number and friction factor, established through regression analysis involving key parameters such as Reynolds number (Re), Prandtl number (Pr), radial v-cut angle (phi), and axial v-cut angle (theta), demonstrate robust results within a narrow range of +/- 5% for the Nusselt number and +/- 7% for the friction factor. In summary, this investigation not only advances our understanding of heat transfer enhancement but also presents tangible pathways for implementing enhanced heat exchanger designs, contributing significantly to energy-efficient thermal systems.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Influence of the typical twisted tape inserts into the inner tube of double-pipe heat exchanger: A limited review
    Kadhim, Saif Ali
    Hammoodi, Karrar A.
    Ali, Hayder Mohsin
    Rashid, Farhan Lafta
    Togun, Hussein
    Alsayah, Ahmed Mohsin
    Hussein, Ahmed Kadhim
    Abd, Hussain Saad
    Omle, Issa
    RESULTS IN ENGINEERING, 2025, 25
  • [22] Heat transfer enhancement in double pipe heat exchanger: exploring twisted tape inserts with dimple configuration
    Heeraman, Jatoth
    Sandeep, Chinta
    Chaurasiya, Prem Kumar
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (16) : 8839 - 8856
  • [23] Numerical analysis of flow and heat transfer enhancement in a horizontal pipe with P-TT and V-Cut twisted tape
    Abed, Azher M.
    Majdi, Hasan Sh
    Hussein, Zainab
    Fadhil, Doaa
    Abdulkadhim, Ammar
    CASE STUDIES IN THERMAL ENGINEERING, 2018, 12 : 749 - 758
  • [24] Effect of twisted tape inserts on heat transfer, friction factor of Fe3O4 nanofluids flow in a double pipe U-bend heat exchanger
    Kumar, N. T. Ravi
    Bhramara, P.
    Kirubeil, A.
    Syam Sundar, L.
    Singh, Manoj K.
    Sousa, Antonio C. M.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2018, 95 : 53 - 62
  • [25] Numerical study on heat transfer enhancement and flow characteristics of double pipe heat exchanger fitted with rectangular cut twisted tape
    Barzegar, Ali
    Jalali Vahid, Dovood
    HEAT AND MASS TRANSFER, 2019, 55 (12) : 3455 - 3472
  • [26] Intensification of forced convection heat transfer using biological nanofluid in a double-pipe heat exchanger
    Sarafraz, M. M.
    Hormozi, F.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 66 : 279 - 289
  • [27] Numerical Analysis of Heat transfer Enhancement in a double pipe heat exchanger with aholed twisted tape
    Kumar, Akarsh
    Sureka, Ujjawal
    Kumar, Shiva
    INTERNATIONAL CONFERENCE ON RESEARCH IN MECHANICAL ENGINEERING SCIENCES (RIMES 2017), 2018, 144
  • [28] Study of thermal performance of double pipe heat exchanger using W-cut twisted tape
    Dandoutiya, Bhrant Kumar
    Kumar, Arvind
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (02) : 5221 - 5238
  • [29] Experimental Study of Heat Transfer Enhancement in a Concentric Double Pipe Heat Exchanger with Different Axial Pitch Ratio of Perforated Twisted Tape Inserts
    Yaningsih, Indri
    Istanto, Tri
    Wijayanta, Agung Tri
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE AND EXHIBITION OF SUSTAINABLE ENERGY AND ADVANCED MATERIALS 2015 (ICE-SEAM 2015), 2016, 1717
  • [30] INVESTIGATION ON THE ENHANCEMENT OF HEAT TRANSFER IN COUNTERFLOW DOUBLE-PIPE HEAT EXCHANGER USING NANOFLUIDS
    Balan, Varadhan
    Ramakrishnan, Surendran
    Palani, Gopinath
    Selvaraju, Mayakannan
    THERMAL SCIENCE, 2024, 28 (1A): : 233 - 240