Questioning the Role of Carotid Artery Ultrasound in Assessing Fluid Responsiveness in Critical Illness: A Systematic Review and Meta-Analysis

被引:1
作者
Walker, Samuel C. D. [1 ]
Lipszyc, Adam C. [2 ]
Kilmurray, Matthew [1 ]
Wilding, Helen [3 ]
Akhlaghi, Hamed [1 ,4 ]
机构
[1] St Vincents Hosp, Dept Emergency Med, Melbourne, Vic, Australia
[2] St Vincents Hosp, Dept Anaesthesia & Acute Pain Med, Melbourne, Vic, Australia
[3] St Vincents Hosp, Lib Serv, Melbourne, Vic, Australia
[4] Univ Melbourne, Dept Med Educ, Melbourne, Vic, Australia
关键词
VOLUME RESPONSIVENESS; CARDIAC-OUTPUT; SEPTIC SHOCK; BLOOD-FLOW; DOPPLER; SEPSIS; TIME; CARE; THERMODILUTION; BIOREACTANCE;
D O I
10.1155/2024/9102961
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. A noninvasive and accurate method of identifying fluid responsiveness in hemodynamically unstable patients has long been sought by physicians. Carotid ultrasound (US) is one such modality previously canvassed for this purpose. The aim of this novel systematic review and meta-analysis is to investigate whether critically unwell patients who are requiring intravenous (IV) fluid resuscitation (fluid responders) can be identified accurately with carotid US. Methods. The protocol was registered with PROSPERO on the 30/11/2022 (ID number: CRD42022380284). Studies investigating carotid ultrasound accuracy in assessing fluid responsiveness in hemodynamically unstable patients were included. Studies were identified through searches of six databases, all run on 4 November 2022, Medline, Embase, Emcare, APA PsycInfo, CINAHL, and Cochrane Library. Risk of bias was assessed using the QUADAS-2 and the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) guidelines. Results were pooled, meta-analysis was conducted where amenable, and hierarchical summary receiver operating characteristic models were established to compare carotid ultrasound measures. Results. Seventeen studies were included (n = 842), with 1048 fluid challenges. 441 (42.1%) were fluid responsive. Four different carotid US measures were investigated, including change in carotid doppler peak velocity (triangle CDPV), carotid blood flow (CBF), change in carotid artery velocity time integral (triangle CAVTI), and carotid flow time (CFT). Pooled carotid US had a pooled sensitivity, specificity, and AUROC with 95% confidence intervals (CI) of 0.73 (0.66-0.78), 0.82 (0.72-0.90), and 0.81 (0.78-0.85), respectively. triangle CDPV had sensitivity, specificity, and AUROC with 95% CI of 0.72 (0.64-0.80), 0.87 (0.73-0.94), and 0.82 (0.78-0.85), respectively. CBF had sensitivity, specificity, and AUROC with 95% CI of 0.70 (0.56-0.80), 0.80 (0.50-0.94), and 0.77 (0.78-0.85), respectively. Risk of bias and assessment was undertaken using the QUADAS-2 and GRADE tools. The QUADAS-2 found that studies generally had an unclear or high risk of bias but with low applicability concerns. The GRADE assessment showed that triangle CDPV and CBF had low accuracy for sensitivity and specificity. Conclusion. It appears that carotid US has a limited ability to predict fluid responsiveness in critically unwell patients. triangle CDPV demonstrates the greatest accuracy of all measures analyzed. Further high-quality studies using consistent study design would help confirm this.
引用
收藏
页数:19
相关论文
共 49 条
  • [31] Emergency department non-invasive cardiac output study (EDNICO): an accuracy study
    McGregor, David
    Sharma, Shrey
    Gupta, Saksham
    Ahmed, Shanaz
    Harris, Tim
    [J]. SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2020, 28 (01)
  • [32] Predicting fluid responsiveness in ICU patients - A critical analysis of the evidence
    Michard, F
    Teboul, JL
    [J]. CHEST, 2002, 121 (06) : 2000 - 2008
  • [33] Accuracy of Ultrasonographic Measurements of Inferior Vena Cava to Determine Fluid Responsiveness: A Systematic Review and Meta-Analysis
    Orso, Daniele
    Paoli, Irene
    Piani, Tommaso
    Cilenti, Francesco L.
    Cristiani, Lorenzo
    Guglielmo, Nicola
    [J]. JOURNAL OF INTENSIVE CARE MEDICINE, 2020, 35 (04) : 354 - 363
  • [34] Carotid vs. aortic velocity time integral and peak velocity to predict fluid responsiveness in mechanically ventilated patients. A comparative study
    Pace, Rocco
    Lassola, Sergio
    Miori, Sara
    Cammarota, Gianmaria
    Barbariol, Federico
    Vetrugno, Luigi
    [J]. MINERVA ANESTESIOLOGICA, 2022, 88 (05) : 352 - 360
  • [35] Pezzullo J., Interactive statistical pages project
  • [36] Survival and quality of life after prolonged intensive care unit stay
    Rimachi, R.
    Vincent, J. -L.
    Brimioulle, S.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2007, 35 (01) : 62 - 67
  • [37] Carotid Doppler flowmetry correlates poorly with thermodilution cardiac output following cardiac surgery
    Roehrig, C.
    Govier, M.
    Robinson, J.
    Aneman, A.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2017, 61 (01) : 31 - 38
  • [38] Persistent microcirculatory alterations are associated with organ failure and death in patients with septic shock
    Sakr, Y
    Dubois, MJ
    De Backer, D
    Creteur, J
    Vincent, JL
    [J]. CRITICAL CARE MEDICINE, 2004, 32 (09) : 1825 - 1831
  • [39] Variables influencing the prediction of fluid responsiveness: a systematic review and meta-analysis
    Sanchez, Jorge Ivan Alvarado
    Ruiz, Juan Daniel Caicedo
    Fernandez, Juan Jose Diaztagle
    Martinez, Luis Eduardo Cruz
    Hernandez, Fredy Leonardo Carreno
    Herrera, Carlos Andres Santacruz
    Ospina-Tascon, Gustavo Adolfo
    [J]. CRITICAL CARE, 2023, 27 (01)
  • [40] Implementation and outcomes of the Multiple Urgent Sepsis Therapies (MUST) protocol
    Shapiro, NI
    Howell, MD
    Talmor, D
    Lahey, D
    Ngo, L
    Buras, J
    Wolfe, RE
    Weiss, JW
    Lisbon, A
    [J]. CRITICAL CARE MEDICINE, 2006, 34 (04) : 1025 - 1032