Row Transmission for High Volume-Rate Ultrasound Imaging With a Matrix Array

被引:1
作者
Wu, Xiaochuan [1 ]
Lee, Wei-Ning [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
[2] Univ Hong Kong, Biomed Engn Programme, Hong Kong, Peoples R China
关键词
2-D array; abdominal aorta (AA); coded excitation; motion estimation; spatial resolution; volumetric ultrasound; COLUMN-ADDRESSED ARRAYS; RADIATION-PATTERN; 2-D ARRAYS; 3-D; TRANSDUCER; DESIGN;
D O I
10.1109/TUFFC.2024.3396269
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The widely used Vermon 1024-element matrix array for 3-D ultrasound imaging has three blank rows in the elevational direction, which breaks the elevation periodicity, thus degrading volumetric image quality. To bypass the blank rows in elevation while maintaining the steering capability in azimuth, we proposed a row-transmission (RT) scheme to improve 3-D spatial resolution. Specifically, we divided the full array into four apertures, each with multiple rows along the elevation. Each multirow aperture (MRA) was further divided into subapertures to transmit diverging waves (DWs) sequentially. Coherent DW compounding (CDWC) was realized in azimuth, while the elevation was multielement synthetic aperture (M-SA) imaging by regarding each row as an array of dashed line elements. An in-house spatiotemporal coding strategy, cascaded synthetic aperture (CaSA), was incorporated into the RT scheme as RT-CaSA to increase the signal-to-noise ratio (SNR). We compared the proposed RT with conventional bank-by-bank transmission-reception (Bank) and sparse-random-aperture compounding (SRAC) in a wire phantom and the in vivo human abdominal aorta (AA) to assess the performance of anatomical imaging and aortic wall motion estimation. Phantom results demonstrated superior lateral resolution achieved by our RT scheme (+19.52% and +16.88% versus Bank, +15.32% and +19.72% versus SRAC, in the azimuth-depth and elevation-depth planes, respectively). Our RT-CaSA showed excellent contrast ratios (CRs) (+8.19 and +8.08 dB versus Bank, +6.81 and +5.85 dB versus SRAC, +0.99 and +0.90 dB versus RT) and the highest in vivo aortic wall motion estimation accuracy. The RT scheme was demonstrated to have potential for various matrix array-based 3-D imaging research.
引用
收藏
页码:659 / 672
页数:14
相关论文
共 32 条
[1]   Sparse 2-D Arrays for 3-D phased array imaging - Design methods [J].
Austeng, A ;
Holm, S .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) :1073-1086
[2]   High-frame-rate volume imaging using sparse-random-aperture compounding [J].
Bernal, Miguel ;
Cunitz, Bryan ;
Rohrbach, Daniel ;
Daigle, Ron .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17)
[3]   Imaging Performance for Two Row-Column Arrays [J].
Bouzari, Hamed ;
Engholm, Mathias ;
Nikolov, Svetoslav Ivanov ;
Stuart, Matthias Bo ;
Thomsen, Erik Vilain ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (07) :1209-1221
[4]   Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Phantom Study [J].
Bouzari, Hamed ;
Engholm, Mathias ;
Beers, Christopher ;
Stuart, Matthias Bo ;
Nikolov, Svetoslav Ivanov ;
Thomsen, Erik Vilain ;
Jensen, Jorgen Arendt .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (07) :1182-1192
[5]   3-D Imaging Using Row-Column-Addressed Arrays With Integrated Apodization-Part II: Transducer Fabrication and Experimental Results [J].
Christiansen, Thomas Lehrmann ;
Rasmussen, Morten Fischer ;
Bagge, Jan Peter ;
Moesner, Lars Nordahl ;
Jensen, Jorgen Arendt ;
Thomsen, Erik Vilain .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (05) :959-971
[6]   Three-dimensional ultrasound imaging [J].
Fenster, A ;
Downey, DB ;
Cardinal, HN .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :R67-R99
[7]   4D in vivo ultrafast ultrasound imaging using a row-column addressed matrix and coherently-compounded orthogonal plane waves [J].
Flesch, M. ;
Pernot, M. ;
Provost, J. ;
Ferin, G. ;
Nguyen-Dinh, A. ;
Tanter, M. ;
Deffieux, T. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11) :4571-4588
[8]   4-D Ultrafast Shear-Wave Imaging [J].
Gennisson, Jean-Luc ;
Provost, Jean ;
Deffieux, Thomas ;
Papadacci, Clement ;
Imbault, Marion ;
Pernot, Mathieu ;
Tanter, Mickael .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (06) :1059-1065
[9]   High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming [J].
Hasegawa, Hideyuki ;
Kanai, Hiroshi .
JOURNAL OF MEDICAL ULTRASONICS, 2011, 38 (03) :129-140
[10]   Synthetic aperture ultrasound imaging [J].
Jensen, Jorgen Arendt ;
Nikolov, Svetoslav Ivanov ;
Gammelmark, Kim Lokke ;
Pedersen, Morten Hogholm .
ULTRASONICS, 2006, 44 :E5-E15