Calibration algorithms for continuous glucose monitoring systems based on interstitial fluid sensing

被引:2
|
作者
Sun, Tianyi [1 ]
Liu, Jentsai [2 ]
Chen, Ching Jung [3 ,4 ]
机构
[1] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Coll Mat Sci & Optielect Technol, Res Ctr Mat Sci & Optielect Technol, Beijing, Peoples R China
[3] Univ Chinese Acad Sci, Res Ctr Mat Sci & Optielectron Technol, Sch Optoelect, Beijing, Peoples R China
[4] Univ Chinese Acad Sci, Res Ctr Mat Sci & Optielect Technol, Beijing, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2024年 / 260卷
关键词
Continuous glucose monitoring (CGM); Calibration; Interstitial fluid glucose (IG); Blood glucose (BG); IG-BG kinetic; Dynamic estimation; SENSORS; KINETICS; ACCURACY; SCIENCE; PLASMA; SKIN;
D O I
10.1016/j.bios.2024.116450
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Continuous glucose monitoring (CGM) is of great importance to the treatment and prevention of diabetes. As a proven commercial technology, electrochemical glucose sensor based on interstitial fluid (ISF) sensing has high sensitivity and wide detection range. Therefore, it has good promotion prospects in noninvasive or minimallyinvasive CGM system. However, since there are concentration differences and time lag between glucose in plasma and ISF, the accuracy of this type of sensors are still limited. Typical calibration algorithms rely on simple linear regression which do not account for the variability of the sensitivity of sensors. To enhance the accuracy and stability of CGM based on ISF, optimization of calibration algorithm for sensors is indispensable. While there have been considerable researches on improving calibration algorithms for CGM, they have still received less attention. This article reviews the problem of typical calibration and presents the outstanding calibration algorithms in recent years. Finally, combined with existing research and emerging sensing technologies, this paper makes an outlook on the future calibration algorithms for CGM sensors.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] PERFORMANCE ASSESSMENT OF A CONTINUOUS GLUCOSE MONITORING CALIBRATION ALGORITHM IN HYPOGLYCEMIA
    Mahmoudi, Z.
    Jensen, M. Hasselstrom
    Johansen, M. Dencker
    Christensen, T. F.
    Tarnow, L.
    Christiansen, J. S.
    Hejlesen, O. K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A75 - A75
  • [42] Multivariate calibration of NIR spectroscopic sensors for continuous glucose monitoring
    Goodarzi, Mohammad
    Sharma, Sandeep
    Ramon, Herman
    Saeys, Wouter
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 67 : 147 - 158
  • [43] Exploration of micro-miniature venturi pump for continuous glucose monitoring through interstitial fluid (ISF) extraction
    Gavali, Sachin Ramchandra
    Prashant, Pawar M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2025, 239 (03) : 885 - 898
  • [45] Progress toward implantable fluorescence-based sensors for monitoring glucose levels in interstitial fluid
    McShane, MJ
    O'Neal, DP
    Russell, RJ
    Pishko, MV
    Coté, GL
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS V, 2000, 3923 : 78 - 87
  • [46] Part I: Continuous glucose monitoring systems
    Moorman, John M. M.
    JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY, 2020, 3 (04): : 843 - 847
  • [47] Measurement of glucose concentration in interstitial fluid - an alternative or a supplement to conventional blood glucose monitoring?
    Kublin, Oskar
    Stepien, Mariusz
    CLINICAL DIABETOLOGY, 2019, 8 (02): : 121 - 126
  • [48] Improving the Accuracy of Pdot-Based Continuous Glucose Monitoring by Using External Ratiometric Calibration
    Sun, Kai
    Liu, Siyang
    Liu, Jing
    Ding, Zhaoyang
    Jiang, Yifei
    Zhang, Jicheng
    Chen, Haobin
    Yu, Jiangbo
    Wu, Changfeng
    Chiu, Daniel T.
    ANALYTICAL CHEMISTRY, 2021, 93 (04) : 2359 - 2366
  • [49] Does Glucose Level at Calibration Influence Accuracy of Continuous Glucose Monitoring Readings In Vitro?
    Iscoe, Katherine E.
    Davey, Raymond J.
    Fournier, Paul A.
    DIABETES, 2011, 60 : A243 - A243
  • [50] CONTINUOUS BLOOD GLUCOSE MONITORING SYSTEM USING INTRAVENOUS MICRODIALYSIS AND GLUCOSE SENSING
    Schaller-Ammann, R.
    Greiner, H.
    Huber, A.
    O'Connell, M.
    Krejci, J.
    Porro, G.
    Korsatko, S.
    Gurban, J.
    Deller, S.
    Brunner, M.
    Berghofer, A.
    Priedl, J.
    Zijlstra, E.
    Heise, T.
    Pieber, T. R.
    Schaupp, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A72 - A72