Performance of calcium quantifications on low-dose photon-counting detector CT with high-pitch: A phantom study

被引:1
作者
Zhou, Shanshui [1 ,2 ]
Liu, Peng [1 ]
Dong, Haipeng [1 ]
Li, Jiqiang [1 ]
Xu, Zhihan [3 ]
Schmidt, Bernhard [4 ]
Lin, Shushen [3 ]
Yang, Wenjie [1 ]
Yan, Fuhua [1 ,2 ]
Qin, Le [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Radiol, 197 Ruijin Er Rd, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Coll Hlth Sci & Technol, Fac Med Imaging Technol, 150 Ruijin Er Rd, Shanghai 200025, Peoples R China
[3] Siemens Healthineers, 399 West Haiyang Rd, Shanghai 200126, Peoples R China
[4] Siemens Healthineers, Siemensstr 3, D-91301 Erlangen, Germany
关键词
Computed tomography; Photon-counting CT; High-pitch; Low dose; Calcium quantification; DUAL-ENERGY CT; CORONARY-ARTERY CALCIUM; BONE-MINERAL DENSITY; COMPUTED-TOMOGRAPHY; ATTENUATION; ACCURACY; OSTEOPOROSIS; ANGIOGRAPHY; DXA;
D O I
10.1016/j.heliyon.2024.e32819
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To evaluate the performance of calcium quantification on photon-counting detector CT (PCD-CT) with high-pitch at low radiation doses compared to third-generation dual-source energy-integrating detector CT (EID-CT). Materials and methods: The phantom with three calcium inserts (50, 100, and 300 mg of calcium per milliliter), with and without the elliptical outer layer, was evaluated using high-pitch (3.2) and standard pitch (0.8) on PCD-CT, and standard pitch on EID-CT. Scans were performed with different tube voltages (PCD-CT: 120 and 140 kilo-voltage peak [kVp]; EID-CT: 70/Sn150 and 100/Sn150 kVp) and four radiation doses (1, 3, 5, and, 10 milli-Gray [mGy]). Utilizing the true calcium concentrations (CCtrue) of the phantom as the gold standard references, regression equations for each kVp setting were formulated to convert CT attenuations (CaCT) into measured calcium concentrations (CCm). The correlation analysis between CaCT and CCtrue was performed. The percentage absolute bias (PAB) was calculated from the differences between CCm and CCtrue and used to analyze the effects of scanning parameters on calcium quantification accuracy. Results: A strong correlation was found between CaCT and CCtrue on PCD-CT (r > 0.99) and EID-CT (r > 0.98). For high- and standard-pitch scans on PCD-CT, the accuracy of calcium quantification is comparable (p = 0.615): the median (interquartile range [IQR]) of PAB was 5.59% (2.79%-8.31%) and 4.87 % (2.62%-8.01%), respectively. The PAB median (IQR) was 7.43% (3.77%-11.75%) for EID-CT. The calcium quantification accuracy of PCD-CT is superior to EID-CT at the large phantom (5.46% [2.68%-9.55%] versus 9.01% [6.22%-12.74%]), and at the radiation dose of 1 mGy (4.43% [2.08%-8.59%] versus 13.89% [8.93%-23.09%]) and 3 mGy (4.61% [2.75%-6.51%] versus 9.97% [5.17%-14.41%]), all p < 0.001. Conclusions: Calcium quantification using low-dose PCD-CT with high-pitch scanning is feasible and accurate, and superior to EID-CT.
引用
收藏
页数:13
相关论文
共 46 条
[1]   High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction [J].
Apfaltrer, Georg ;
Albrecht, Moritz H. ;
Schoepf, U. Joseph ;
Duguay, Taylor M. ;
De Cecco, Carlo N. ;
Nance, John W. ;
De Santis, Domenico ;
Apfaltrer, Paul ;
Eid, Marwen H. ;
Eason, Chelsea D. ;
Thompson, Zachary M. ;
Bauer, Maximilian J. ;
Varga-Szemes, Akos ;
Jacobs, Brian E. ;
Sorantin, Erich ;
Tesche, Christian .
EUROPEAN RADIOLOGY, 2018, 28 (07) :3097-3104
[2]   Diagnostic image quality of a comprehensive high-pitch dual-spiral cardiothoracic CT protocol in patients with undifferentiated acute chest pain [J].
Bamberg, Fabian ;
Marcus, Roy ;
Sommer, Wieland ;
Schwarz, Florian ;
Nikolaou, Konstantin ;
Becker, Christoph R. ;
Reiser, Maximilian F. ;
Johnson, Thorsten R. C. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) :3697-3702
[3]   Diagnostic accuracy of quantitative dual-energy CT-based bone mineral density assessment in comparison to Hounsfield unit measurements using dual x-ray absorptiometry as standard of reference [J].
Booz, Christian ;
Noeske, Jochen ;
Albrecht, Moritz H. ;
Lenga, Lukas ;
Martin, Simon S. ;
Yel, Ibrahim ;
Huizinga, Nicole A. ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
[4]   Photon-counting x-ray detectors for CT [J].
Danielsson, Mats ;
Persson, Mats ;
Sjolin, Martin .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03)
[5]   Quantification of Urinary Stone Volume: Attenuation Threshold-based CT Method-A Technical Note [J].
Demehri, Shadpour ;
Kalra, Mannudeep K. ;
Rybicki, Frank J. ;
Steigner, Michael L. ;
Lang, Matthew J. ;
Houseman, E. Andres ;
Curhan, Gary C. ;
Silverman, Stuart G. .
RADIOLOGY, 2011, 258 (03) :915-922
[6]   Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. .
MEDICAL PHYSICS, 2008, 35 (03) :1135-1144
[7]   Coronary Computed Tomography Angiography-Based Calcium Scoring In Vitro and In Vivo Validation of a Novel Virtual Noniodine Reconstruction Algorithm on a Clinical, First-Generation Dual-Source Photon Counting-Detector System [J].
Emrich, Tilman ;
Aquino, Gilberto ;
Schoepf, U. Joseph ;
Braun, Franziska M. ;
Risch, Franka ;
Bette, Stefanie J. ;
Woznicki, Piotr ;
Decker, Josua A. ;
O'Doherty, Jim ;
Brandt, Verena ;
Allmendinger, Thomas ;
Nowak, Tristan ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Kroencke, Thomas J. ;
Scheurig-Muenkler, Christian ;
Varga-Szemes, Akos ;
Schwarz, Florian .
INVESTIGATIVE RADIOLOGY, 2022, 57 (08) :536-543
[8]   Photon-Counting Detector CT: Key Points Radiologists Should Know [J].
Esquivel, Andrea ;
Ferrero, Andrea ;
Mileto, Achille ;
Baffour, Francis ;
Horst, Kelly ;
Rajiah, Prabhakar Shantha ;
Inoue, Akitoshi ;
Leng, Shuai ;
McCollough, Cynthia ;
Fletcher, Joel G. .
KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (09) :854-865
[9]   High-Pitch Wide-Coverage - Fast-Kilovoltage-Switching Dual-Energy CT: Impact of Pitch on Noise, Spatial Resolution, and Iodine Quantification in a Phantom Study [J].
Euler, Andre ;
Solomon, Justin ;
Farjat, Alfredo E. ;
Nelson, Rendon C. ;
Samei, Ehsan ;
Marini, Daniele .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (03) :W64-W72
[10]   Characterization of Urinary Stone Composition by Use of Whole-body, Photon-counting Detector CT [J].
Ferrero, Andrea ;
Gutjahr, Ralf ;
Halaweish, Ahmed F. ;
Leng, Shuai ;
McCollough, Cynthia H. .
ACADEMIC RADIOLOGY, 2018, 25 (10) :1270-1276